OPERATING METHOD 

 

Auto mode 

·The appliance will operate in auto mode directly once it is turned on. Press 
MODE button also could choose this mode. 
·Under Auto mode, the running mode of air conditioner depends on the room 
temperature, here under is called Ta.   

If Ta 

80°F

27

,

    it will enter cool mode. 

If 66°F

19

<Ta<80°F

27

, it will enter dehumidifying mode with default 

low speed fan, and the fan speed can not be changed higher. 

If Ta

66°F

19

it will enter fan mode with default high speed on the 

condition that the machine is cool only model. 
 
·Once the working mode is selected, the mode will not change as ambient 
temperature changes. 
 

Cool mode 

·Press MODE button (or Cool button, use remote control only) to choose Cool 
mode, the LCD will display 

.  

·Press UP or DOWN button to set room temperature between 62°F

17

to 

88°F

30

·Press FAN button (or Low/Med/High button) to select low, middle or high fan 
speed. The LCD will display  ,

 or 

 accordingly.  

·Press Swing button to make the wind swing (use remote control only). The LCD 
will display 

 

Dehumidifying mode 

·Press MODE button (or Dry button, use remote control only) to choose Dry 
mode, the LCD will display  . 
·In Dry mode fan speed is preset. Speed button is not available. The 
temperature can’t be set either. 
·Press Swing button to make the wind swing (use remote control only). The LCD 
will display 

·Do not use air outlet duct. Connect the up drain port with one end of a drain pipe 
and let the other end to a vessel or to sanitary sewer 
·Dry mode can not be used to cool the room. 
 

Fan mode 

·Press MODE button (or Fan button, use remote control only) to choose Fan 
mode, the LCD will display 

Содержание AP14000

Страница 1: ...PORTABLE AIR CONDITIONER AP14000 Thank you for selecting super quality air conditioner Please be sure to read this manual carefully before using it Any question please contact the professional servic...

Страница 2: ...1 CONTENTS CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS 2 4 INSTALLATION 5 6 PARTS NAME 7 CONTROL PANEL 8 REMOTE CONTROL 9 OPERATING METHOD 10 11 WATER DRAINAGE 12 MAINTENANCE 13 TROUBLE SHOOTING 14...

Страница 3: ...the air conditioner Be sure all packaging materials are removed from the air conditioner before use It can result in personal injury Do not disassemble or modify the air conditioner or the power cord...

Страница 4: ...unplug the air conditioner when it will not be used for extended period of time This conserves energy and reduces the chance of accidents Secure the wheels with blocks to prevent the air conditioner f...

Страница 5: ...nd if necessary install a properly grounded outlet This air conditioner must be plugged into a grounded 60 Hz 120 VAC outlet protected by a 15 amp time delay fuse or circuit breaker This air condition...

Страница 6: ...of the unit Half open the window and let the air outlet duct get through The window slider kit has been designed to fit most standard vertical and horizontal windows It is adjustable Wrong mounting T...

Страница 7: ...cation of this product Do not replace or prolong it with your own private hose as this could cause mal function BE CAREFUL Use the shortest possible length When mounting we advise to keep the exhaust...

Страница 8: ...r 7 Evaporator air inlet 8 Up drain port used when Continuous Drainage or in dry mode 9 Power cord 10 Down drain port when water tank is full or not use any longer in winter season Check all the acces...

Страница 9: ...tton press this button to select high middle or low fan speed 4 TIME button press this button to set timer on timer off or no timer 5 UP DOWN button press these buttons to set room temperature or time...

Страница 10: ...9 REMOTE CONTROL 1 High fan speed 2 Middle fan speed 3 Low fan speed 4 Swing 5 Timer 6 Up 7 Down 8 Cool mode 9 Dry mode 10 Fan mode 11 Celsius and Fahrenheit exchange 12 Power same as ON OFF...

Страница 11: ...ose Cool mode the LCD will display Press UP or DOWN button to set room temperature between 62 F 17 to 88 F 30 Press FAN button or Low Med High button to select low middle or high fan speed The LCD wil...

Страница 12: ...e air outlet duct Timer on When the appliance is switch off press Timer button to set timer on Press Up or Down button to adjust time 0 24 hour The Time on light indicator will illuminate Timer off Wh...

Страница 13: ...water drainage During dehumidifying mode remove the drain plug from the back of the unit then install a drain pipe 10mm inner dimension and place the open end of the hose into any vessel such as buck...

Страница 14: ...reduce Open the air filter cover upwards and then take out the air filter Wash the air filter by immersing it gently into warm about 40 104 F water with a neutral detergent rinse it and dry it thorou...

Страница 15: ...rty filter Clean or replace the filter s Air inlet or air outlet blocked Remove the blockage Room temperature lower than the selected value Change temperature selection Fan speed is low Choose suitabl...

Отзывы: