INSTALLATION
Connection with a flexible steel hose
If the cooker is connected according to the
class 2 specifications, sub-class I, only flex
-
ible metal hose can be used which meet the
valid national regulations. Gas feeding con-
nector must be G ½” threaded coupling.
Use only pipes and fittings that meet the
requirements of the valid standards. Maxi-
mum admissible length of the flexible hose
is 2000 mm.
Make sure the connection is not touching
any mobile elements which could damage
the hose.
Connection with a stable pipework
The cooker comes with a G ½” threaded
coupling.
The connection to gas supply must be done in
a manner that excludes stresses in any point
of the pipework or parts of the appliance.
Make sure you do not exceed the torque when
making the connection (maximum torque is
20 Nm). Otherwise, the connection may be
faulty or leaks may occur.
The gas hose should not touch metal ele-
ments of the cooker back shield.
The cooker is manufactured to work with
a one-phase alternating current (230V
1 N~50 Hz) and is equipped with a 3 x 1,5
mm
2
connection lead of 1,5 m length with
a plug including a protection contact*.
A connection socket for electricity supply
should be equipped with a protection
pin and may not be located above the
cooker. After the cooker is positioned, it is
necessary to make the connection socket
accessible to the user.
Before connecting the cooker to the
socket, check if:
- the fuse and electricity supply are able to
withstand the cooker load,
- the electricity supply is equipped with an
efficacious ground system which meets
the requirements of current standards
and provisions,
- the plug is within easy reach.
Electrical connection
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
Important!
If the fixed power supply cable is
damaged, it should be replaced
at the manufacturer or at an au-
thorized servicing outlet, or by a
qualified person to avoid danger.