Outdoor LoRa Data Logger
40
2.5 Event Configuration
The Event Trigger function can use a certain input signal (device) as trigger source for an event rule. If there is
any enabled event rule, the data logger will check the trigger source once per second to determine event
trigger or not. When the designated condition matches, the event rule will be triggered and corresponding
event action will take place accordingly.
The data logger supports up to 3 event rules. Click the
Edit
button to edit a specific event trigger. For each
event rule (If
condition
then
action
), you have to specify the condition part, min. hold time, and the action part.
Condition part: (
condition 1
)
AND
/
OR
(
condition 2
)
min. Hold Time: Above
Condition
remains
TRUE
for at least
T
hold
(condition hold time)
Action part: make
DO High
,
DO Low
, or set
Tirgger Schedule event flag
till the condition
FALSE
Name
:
Specify a name as the identifier of the event rule.
Tirgger Source
: Available trigger source can be
AI
s,
DI
s, and
Modbus
. For specific product, there is an
additional
Alert
pin that can be monitored all the time, even the data logger is in sleep
mode. You can select one of them as the event trigger source.