PARTS SCHEDULE - 3" TAF-750 FILTER Section 1

 

 
 

NO. 

Cat. Num. 

Description 

QTY 

Material 

710103-001269 

Housing 3" TAF-750 BSPT Machined 

NYLON 

710103-001271 

Housing 3" TAF-750 NPT Machined 

NYLON 

700190-001924 

Pressure  Balancing Assembly 3" TAF-750 

Various 

2.1 

770102-000092 

O-Ring Seal P2-125 Scanner Bearing NBR"S" 

NBR 

710103-001271 

Housing 3" TAF-750 NPT Machined 

NYLON 

SEE TABLE 

Screen TAF-750 

Various 

4.1 

770102-000130 

O-Ring Seal P2-242 (2"/3 Screen) NBR"S" 

NBR 

700190-001926 

Suction Scanner 3" TAF-750 

Various 

770102-000169 

O-Ring Seal P2-437  

NBR 

710103-000562 

2"T-S,3"T Lid PA BSPT 

NYLON 

710103-000544 

Nylon Tightening nut Black (T filters)  

RPA 

770102-000069 

O-Ring Rubber Seal P2-028 

NBR 

710103-000704 

Long Bearing For Suction Scanner 2"T 

Delrin 

10 

770102-000096 

O-Ring Seal P2-129 NBR 

NBR 

11 

780101-000955 

Connector 11/2"FX11/2"M 

ST.37-2 

12 

730103-000444 

1-1/2" Exhaust Valve 

 Various 

13 

720501-000198 

L-Connector 1/4"X8MM Red/Black  

NYLON 

14 

730110-000034 

Finger Filter 

 Various 

15 

720501-000228 

T-Connector 8MMX8MMX8MM Black-Red 

PVC 

16 

710101-000765 

Motor Connecting Flange 2" TAF NPT 

NYLON 

16 

710101-000760 

Flange Adaptor (HYDROTAF) 

NYLON 

17 

760103-000094 

Flat Washer M6 DIN125S/ST316 

12 

SST316 

18 

760101-000445 

Hex Bolt Full Thread M6X25 S/ST316 DIN933 

SST316L 

19 

710103-001207 

Endless Worm Shaft Housing TAF 

Delrin 

20 

770101-000036 

MM O-RING SEAL ID10MM TH2MM NBR 70 SHORE 

NBR 

21 

770101-000051 

O-Ring Seal 3.5X45 TAF Motor Housing NBR  

NBR 

22 

710101-000767 

 Seal U-Cup (Scanner Shaft) Hydro-TAF 

NBR 

23 

770101-000049 

O-Ring Seal 30X3 NBR "S" 

NBR 

24 

710103-001247 

Reversible Worm Shaft TAF 

Acetal 

25 

760105-000029 

Slotted Pin 3x20 DIN1481 S/ST 304 

S/ST 304 

26 

710103-001209 

Endless Worm Shaft Tooth S/ST303 

S/ST 303 

27 

760107-000065 

Spring Tooth S/ST302 

S/ST 302 

28 

710103-001210 

Tooth Cover TAF 

S/ST 316L 

29 

760101-000443 

Hex Bolt Full Thread M6X15 S/ST304 DIN933 

ST372 

30 

710103-001216 

Motor Shaft Coupler 

S/ST 316L 

31 

760101-000544 

Socket Set Screw M6X6 SST304 DIN916 

SST304 

32 

710103-001217 

Drive Unit Basis TAF 

S/ST 316L 

33 

720201-000033 

Drive Unit TAF-750 220V AC 1/25 

Various 

32 

720201-000032 

Drive Unit TAF-750 110V AC 60HZ 0.015KW 1/25 

Various 

34 

760101-000607 

Hex Bolt Full Thread M6X60 S/ST316 DIN933 

SST316L 

35 

710103-001212 

Instrumentation Bracket 

S/ST 316L 

36 

720104-000029 

PD Switch UE 24-011  

Various 

37 

760101-000529 

Phillips Pan Machine Screw M4X10 316 

SST316L 

38 

760102-000083 

Hex Nut M4 S/ST304 DIN934 

SST304 

39 

720103-000187 

 3/2 Nc Solenoid Valve (Type B) 24VAC 50Hz 

Various 

39 

720103-000189  

3/2 NC Solenoid Valve 60HZ NC 24VAC 

Various 

40 

720501-000209 

L-Connector 1/8"MX6MM Black-Red 

PP 

 
 

Содержание TAF-750

Страница 1: ...AMIAD Water Systems Ltd 3 TAF 750 FILTERS Serial number Order number Catalog number Filtration degree Tested by Installation Operation and Maintenance Instructions Ref 910101 000116 12 2018 ...

Страница 2: ... of this document or its content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project ...

Страница 3: ... 6 DESCRIPTION OF FILTER OPERATION 7 FILTERING PROCESS 7 SELF CLEANING PROCESS 7 INSTALLATION 8 DESIGN RECOMMENDATIONS 8 INSTALLATION INSTRUCTIONS 8 START UP AND FIRST OPERATION 9 MAINTENANCE 10 CHECKING THE FILTER 10 CHECKING THE PD SWITCH CONNECTORS 10 WINTERIZATION 10 LEAKS 10 PARTS SCHEDULE 3 TAF 750 FILTER SECTION 1 11 PARTS DRAWING 3 TAF 750 FILTER SECTION 1 13 PARTS SCHEDULE DRAWING 3 TAF 7...

Страница 4: ...ds Wasted water per cycle 25 liter 6 6USgallon Minimum flow for flushing 5 7m3 h 25USgpm at 1 5 bar 22 psi Flushing criteria Differential pressure of 0 5 bar 7psi time interval and manual operation Control and electricity Rated operation voltage 110 220 VAC Single phase Electric motor 15 Watt 50 60 Hz Gear output 48 58 R P M Current consumption 0 18 A Control voltage 24 VAC Construction materials ...

Страница 5: ...to avoid water splashing directly on the electrical components or on the control panel 7 Additional safety devices should be installed on hot water applications to avoid skin burn danger Operation Control and Maintenance 1 Disconnect the filter from power supply before maintenance or treatment 2 Loosening or unscrewing bolts should be done only after the pressure in the filter had been released 3 ...

Страница 6: ...3 TAF 750 12 2018 910101 000116 Page 6 of 17 DIMENSIONAL DRAWINGS Approx Required Height For Maintenance N1 N2 N3 41 55 1055 1100 43 31 INLET OUTLET DRAIN 11 50 292 8 87 225 13 48 342 3 55 90 25 93 659 ...

Страница 7: ...loss to develop Self cleaning process The TAF will start the self cleaning process either when the pressure differential across the screen reaches a pre set value or after a predetermined lapse of time The fine screen filter element is cleaned by the suction scanner whose nozzles spiral across the inner surface of the screen The filtration cake is vacuumed from the screen and expelled out the exha...

Страница 8: ...filter in order to enable convenient maintenance 2 The diameter of the inlet pipe must not be smaller than that of the filter inlet 3 Install the filter in a way that enables convenient approach and enough space to dismantle the filter for maintenance purposes 4 It is recommended to install the filter horizontally especially if the water contains sand 5 Ensure the direction of flow is according to...

Страница 9: ...e remains closed or with an open by pass valve This will keep the flow in the filter at a minimum and operate a flushing cycle by pressing the push button on the controller panel 4 Make sure the exhaust valve opens and all stages of the flushing cycle are carried out Attend to leakage if any If necessary change the time setting to ensure complete up and down motion of the suction scanner 5 Gradual...

Страница 10: ...e if necessary 4 Replace the screen 5 Return the cover and twist to tighten Checking the PD switch connectors Check the L Connectors to the PD Switch to make sure that there are no obstructions Winterization Filter operations should be suspended in climates where the filter is exposed to freezing temperatures 1 Check that the outlet valve is closed and perform two manual rinses 2 Close the inlet v...

Страница 11: ... ST316 12 SST316 18 760101 000445 Hex Bolt Full Thread M6X25 S ST316 DIN933 4 SST316L 19 710103 001207 Endless Worm Shaft Housing TAF 1 Delrin 20 770101 000036 MM O RING SEAL ID10MM TH2MM NBR 70 SHORE 1 NBR 21 770101 000051 O Ring Seal 3 5X45 TAF Motor Housing NBR 1 NBR 22 710101 000767 Seal U Cup Scanner Shaft Hydro TAF 1 NBR 23 770101 000049 O Ring Seal 30X3 NBR S 1 NBR 24 710103 001247 Reversib...

Страница 12: ... 1 In Galcon 1 Various 44 760101 000713 Phillips Pan Machine Screw M5X8 S ST316 4 SST316L 45 760101 000530 Phillips Pan Machine Screw M5X8 304 4 SST304 46 770103 000025 Cap Seal 3 4 NBR 1 NBR 47 710101 000674 3 4 Cap Black 1 PP 48 710103 000568 Plastic Flange 3 NPT 2 PP 48 710103 000566 Plastic Flange 3 BSPT 2 PP 49 710105 000041 Flange Support 3 ASA150 2 SAE 1020 50 770102 000150 O Ring Seal P2 3...

Страница 13: ... 13 of 17 PARTS DRAWING 3 TAF 750 FILTER Section 1 21 2 13 18 17 16 23 22 19 26 28 29 27 25 24 30 32 34 17 33 17 52 41 42 44 43 4 4 1 4 4 1 5 6 7 8 9 10 11 12 13 29 35 13 39 40 13 36 13 13 38 37 14 49 48 50 46 47 51 2 31 45 13 15 2 1 20 B ...

Страница 14: ...0190 001935 Suction Scanner W O Shaft 2 S 3 TAF 1 Various 1 1 710101 000751 1 2 4 Suction Scanner Nozzle No 1 6 PP 1 2 710101 000751 2 2 4 Suction Scanner Nozzle No 2 6 PP 1 3 760101 000537 Phillips Pan Tap Screw PT4x20 S ST316 12 S ST 316 2 710103 001275 Suction Scanner Shaft 3 TAF 1 S ST 316L 3 760105 000033 Slotted Pin 3x30 DIN1481 S ST 304 1 S ST 304 ...

Страница 15: ...3 TAF 750 12 2018 910101 000116 Page 15 of 17 CONTROL DRAWING ...

Страница 16: ...This warranty is valid on the condition that the Products are installed according to Amiad s instructions as expressed in Amiad s instruction manuals and according to the technical limitations as stipulated in Amiad s literature or as stated by a representative of Amiad 7 This warranty will not apply to damaged or defective Products resulting from or related to i Fire flood power surges or failure...

Страница 17: ...stems Ltd D N Galil Elyon 1 1233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration http amiad com certificatesDownload asp ...

Отзывы: