34
SAF-X
01.2022
/
001301
-
910101
Installation & Operation Manual
Dismantling and Assembling the Filter Components
Dismantling:
•
Prior to opening the filter, perform flush cycle by pressing the "TEST" push button.
•
Close the filter inlet and outlet valves and open the drain valve to release the pressure and drain the filter.
•
Turn off the power and secure the main-switch.
•
Release the lid bolts (200) from their nuts and open the front lid (2).
•
Pull the Coarse Screen Assembly (8) out of the filter housing.
•
Pull the fine Screen Element (10) out of the filter housing.
•
Release bolts 221 and remove the Side Covers (29).
•
Pull out the Pin Cotter (37) from the Clevis Pin (36)
–
at the filter housing side.
•
Pull out the Clevis Pin (36) to disconnect the scanner from the Drive Shaft.
•
Pull the Scanner out of the filter (11 or 18).
Assembly:
1.
Insert the Suction Scanner into its place and lock it with the Pins 36 & 37.
•
Verify that the hydraulic seals are properly mounted on the fine Screen Element (10). Lubricate the seals with some
silicone lubricant (ML-2 or ML-4).
•
Insert the screen into the filter housing (1). Note the triangle mark on the screen edge. It must point upward in order to
lock the screen in its place and prevent it from turning during flushing.
•
Verify that the hydraulic seal is mounted on the Coarse Screen Assembly (8). Lubricate it with some silicone lubricant
(ML-2 or ML-4).
•
Insert the Coarse Screen Assembly (8) and verify it is properly fits.
•
Verify that the Lid O-ring (100) is in place.
•
Close the filter front lid and tighten is bolts (200) in even manner.
•
Re-connect the power and run a dry flush cycle. Verify all is working good mechanical aspect.
•
Open the filter inlet valve and gradually fill the filter with water. Check and attend any leak.
•
Run a few flush cycles. Verify all is working well.
•
Gradually open the outlet valve and bring the filter back in service.
Removing the Seals-Sleeve:
1.
Removing the Seals-Sleeve (7) is not required for standard service.
In order to take it out, first remove the lid’s O
-Ring (100) and then pull out the Sleeve by holding its internal edge.
2.
Replacement of the hydraulic seals of the Seals-Sleeve (101) and/or the Screen Element (104) is required only in case it
is damaged.
Use Seal Extractor (TL-01) or flat screwdriver to remove the seal from its seat.
3.
Make sure to properly mount the new seal in its seat.
Lubricate the seal with silicone lubricant (ML-2 or ML-4). When insert it back, make sure that the sign TOP
is pointing up.
4.
Put back the Lid’s O
-
Ring Before closing the filter’s front lid.