amiad SAF-1500 Скачать руководство пользователя страница 10

 

 

SAF - 1500   910101-000102 

                                         07.2109 

Page 10 of 26 

 

DESCRIPTION OF FILTER OPERATION

 

Filtering process: 

The  SAF-1500  is  a  sophisticated  yet  easy-to-operate  automatic  filter,  with  a  self-cleaning  mechanism  driven  by  an  electric 
motor.  The  SAF-1500  is  designed  to  work  with  various  types  of  screens  in  filtration  degrees  from  500  to  10  micron,  and  is 
available in 2", 3" and 4" inlet/outlet diameter. 

The filter is available in "In-Line" configuration as well as in "Modular" configuration. 

The water enters through the inlet pipe into the coarse screen from outside in, and through the fine screen from inside out. 
The "filtration cake" accumulates on the fine screen surface and causes head loss to develop. 

The  coarse  screen  is  designed  to  protect  the  cleaning  mechanism  from  large  dirt  particles.  It  should  not  accumulate  large 
quantities of suspended solids and is not cleaned automatically. 

Self-cleaning process: 

The SAF 1500will start the self-cleaning process when the pressure differential across the screen reaches a pre-set value or a 
predetermined lapse of time. 

Cleaning  of  the  filter  element  is  carried  out  by  the  suction  scanner  which  rotates  in  a  spiral  movement  while  removing  the 
filtration cake from the screen and expels it out through the exhaust valve. 

The  rotation  of  the scanner  is  operated  by  a  2-way  (fwd/rev)  drive  unit  that  is  attached  to the  scanner  by  a  threaded  shaft 
which provides the linear movement. 

The  exhaust  valve  is  activated  for  the  duration  of  the  cleaning  cycle  by  a  3-way  solenoid.  During  the  self-cleaning  process, 
which takes approximately 20 seconds, filtered water continues to flow downstream. 

 
 
 
 
 
 
 
 

 

  

 
 
 
 
 
 
 
 

 
 
 
Different modes of filtration: 

The filtration system may be found in one of the following modes: 

1. 

Filtering mode:

 This is the normal function condition. Flushing is not occurring and the power  light on the control board is lit. 

2. 

Flushing mode:

 A mode in which the flushing process is in progress. The motor and exhaust valve are operating according to 

the program. 

3. 

Continuous flushing mode:

 It is possible to activate the self-cleaning mechanism continuously by changing the switch near the 

timer in the control board to "CONT." position. 

4. 

Malfunction  mode:

  During  malfunction  mode  the  self-cleaning  operation  is  stopped,  the  malfunction  light  on  the  control 

board is turned on and an external output is activated  with 24V AC. 

 

Water Outlet  Junction Box 

Water Inlet 

Control Filter 

Exaust Valve 

Drive Unit 

Pressure Differntial Switch 

Содержание SAF-1500

Страница 1: ...AMIAD Water Systems SAF 1500 FILTER Serial number Order number Catalog number Filtration degree Tested by Installation Operation and Maintenance Instructions 910101 000102 07 2019 ...

Страница 2: ... content The confidential nature of and or privilege in the file enclosed is not waived or lost as a result of a mistake or error in this file If you received this file in error please notify Amiad immediately at info amiad com This document does not replace any certified drawing procedure or information provided by Amiad in reference to a specific customer site or project Amiad assumes that all u...

Страница 3: ...RAWING Standard SAF 1500 8 DESCRIPTION OF FILTER OPERATION 10 INSTALLATION 12 MAINTENANCE 14 DISMANTLING AND ASSEMBLING THE FILTER COMPONENTS 16 PARTS LIST Standard SAF 1500 18 PARTS DRAWING Standard SAF 1500 Section 1 Page 1 20 PARTS DRAWING Standard SAF 1500 Section 1 Page 2 20 PARTS SCHEDULE DRAWING Standard SAF 1500 Filter 21 Section 2 Drive Shaft Housing 22 PARTS SCHEDULE DRAWING Standard SAF...

Страница 4: ...ycle time 15 seconds 15 seconds Flushing water per cycle 25 liter 6 6 gallon at 2 bar 30 psi Minimum flow for flushing 6 m3 h 26 USgpm at 2 bar 30 psi Control and electricity Control voltage 24V AC 12V or 24V DC upon request Electric motor 1 4 HP 50 60 Hz 35 42 Gear output R P M Rated operation voltage 3 phase 220 380 440 V 50 60 Hz Single phase 110 220 V 50 60 Hz DC 12V or 24V upon request Curren...

Страница 5: ...ing at the area of the filter to enable good visibility and safe maintenance The user should arrange suitable platforms ladders and safety barriers to enable easy and safe access to the filter without climbing on pipes and other equipment The user should verify that any platform barrier ladder or other such equipment is built installed and used in accordance with the relevant local authorized stan...

Страница 6: ...note that the maximum working pressure indicated at the filter s specifications table includes the pressure caused by fluid hammer and pressure surge effects Civil Engineering Make sure that the filter installation is done by Amiad qualified technicians Make sure that any civil engineering work at the installation site such as construction lifting welding etc is done by qualified workers technicia...

Страница 7: ...e slippage electrification or damage to the equipment caused by moisture While using lifting equipment make sure that the filter or the lifted part is chained securely and in a safe manner Do not leave lifted equipment if there is no necessity Avoid working below lifted equipment Wear a safety helmet goggles gloves and any other personal safety equipment required by the local standards and regulat...

Страница 8: ...ENDED INSTALLATION DRAWING Drawing No 1 Modular configuration Drawing No 2 In line configuration Key Dimensions mm inches 1 3 SAF 1500 2 3 inlet butterfly valve 3 3 by pass valve 4 3 downstream valve 5 3 non return check valve Minimum distance required for maintenance ...

Страница 9: ... D E F SCALE 1 10 Amiad Water Systems Ltd reserves the rights to make changes All copy rights reserved to Amiad Water Systems Ltd 041001 XXXXXX 0 SAF 1500 C ST Filter Polyester Scanner SAF 1500 C ST Filter Polyester Scanner ITAIZ REV DATE DESCRIPTION NAME 1726 5 REF 2537 350 REF 343 REF 195 REF C O G OUTLET INLET Z Y 235 REF 430 REF C O G Z X 335 REF C O G X Y K G 112 A X IS IN CH MM X 2 17 55 Y 2...

Страница 10: ... which rotates in a spiral movement while removing the filtration cake from the screen and expels it out through the exhaust valve The rotation of the scanner is operated by a 2 way fwd rev drive unit that is attached to the scanner by a threaded shaft which provides the linear movement The exhaust valve is activated for the duration of the cleaning cycle by a 3 way solenoid During the self cleani...

Страница 11: ...d on the filter body sends an electric signal when the pressure differential across the screen reaches the pre set value usually 0 5 bar 7 psi The control board registers the signal and operates the flushing process according to its program 2 Manually pressing the TEST push button at the control board 3 The TIMER installed in the control board allows operation of self cleaning process at time inte...

Страница 12: ...nual valve is installed on the exhaust pipe in order to enable regulation of the flushing flow rate 6 The user should arrange suitable lighting at the area of the filter to enable good visibility and safe maintenance 7 The user should arrange suitable platforms and safety barriers to enable easy access to the filter without climbing on pipes and other equipment IMPORTANT Prevent static back pressu...

Страница 13: ... the filter description chapter of this manual 4 Open the inlet valve to the filter while the outlet valve remains closed or with an open by pass valve This will keep the flow in the filter at a minimum and operate a flushing cycle 5 Make sure the exhaust valve opens and all stages of the flushing cycle are carried out Attend to leakage if any 6 Close the 1 4 valve at the low pressure point of the...

Страница 14: ... from the drive shaft housing 4 by unscrewing the wing nuts 29 3 If the Suction Scanner is in the outer position operate a flushing cycle and bring it to the inner position 4 Remove the Split pin 10 and pull out the connecting pin 9 5 Operate a flushing cycle 6 Stop the motor operation when the drive shaft reaches half way of its movement The drive shaft is now separated from the Suction Scanner 7...

Страница 15: ...ILAR Cleaning the coarse screen Close the filter inlet valve 2 Release pressure from the filter by operating a flushing cycle 3 Remove the filter lid 17 pull out the flushing chamber 15 with its seal 4 Pull out the coarse screen 11 and clean it 5 Insert the coarse screen 11 in its position so that it rests on its supports 6 Insert the flushing chamber into the lid 15 17 Make sure the seal is on to...

Страница 16: ...ed in the flushing chamber 5 Insert the coarse screen 11 in its position so that it rests on its supports 6 Insert the flushing chamber 15 make sure the seal is on top of the chamber centering ring with its opening facing the inner side of the filter housing The installation should be done at a slight angle and in circular motion 7 Assemble the lid on the filter housing Tighten the bolts 19 20 in ...

Страница 17: ...bolts Assembly 1 Verify that the O ring 3 is clean and in its place 2 Tighten the flange of the drive shaft housing to the filter with bolts 3 Insert the suction scanner the fine screen and the coarse screen as described previously 4 Connect the drive shaft to the scanner shaft using the connecting pin and split pin 5 Make sure the drive shaft key 21 is fitted properly in the gear box Thread the d...

Страница 18: ...d 4 20 Flat Washer M20 Z Plated 4 21 Drive Shaft Key SAF 1 22 Drive Unit 440AC3PH 0 18KW RMI50 1 28 63 B5 1 23 Hex Bolt Full Thread M8X40 Z Plated 4 24 Hex Nut M8 Z Plated 4 25 Flat Washer M8 Z Plated 8 26 Spring Washer M8 Z Plated 4 27 Drive Shaft Cover PVC SAF 1 28 Socket Head Cap Screw M8x20 S St304 DIN912 2 29 Drive Shaft Housing Cover SAF 1500 1 30 Insrtumentation Combined Bracket SAF 1 31 Al...

Страница 19: ...L Connector 3 4 F M Galvanized 1 49 3 4 BSPT AC BLACK SCREEN 200 M 1 50 Raccord Nipple 1 4 for 3 4 Filter 1 51 Raccord Nut 3 4 for 3 4 Filter 1 52 O Ring Seal P2 112 NBR 1 53 Hydraulic Valve 1 54 Pressure Check Point Connector 1 4 X1 4 1 55 Solenoid Valve 1 56 Control Tube 5 16 Nylon Air Brake 1 6m ...

Страница 20: ...PARTS DRAWING Standard SAF 1500 Section 1 Page 1 18 1 2 3 6 7 6 5 23 25 25 26 24 21 4 22 27 28 19 20 17 16 15 13 11 8 14 9 10 12 29 ...

Страница 21: ...SAF 1500 07 2019 Page 21 of 26 PARTS DRAWING Standard SAF 1500 Section 1 Page 2 56 34 53 54 35 55 41 0 35 48 47 35 56 56 34 33 40 42 41 39 38 31 32 30 46 43 43 44 45 37 36 49 51 50 52 ...

Страница 22: ...F FA 4131 2DN 2 8 Phillips Pan Machine Screw M4x20 DIN7985 3 9 Flat Washer M4 DIN125 S ST304 3 10 Hex Bolt Full Thread M6x35 DIN933 S St 304 3 11 Flat Washer M6 DIN125 S ST316 16 12 Nylon Insert Lock Nut M6 S ST304 DIN985 3 13 Nylon Insert Lock Nut M4 S ST304 DIN985 3 14 SAF 4500 Tightening Nut 1 15 O Ring Seal 24x3 Tightening Nut SAF NBR S 1 16 O Ring Seal 14x3 NBR S 1 17 Hex Bolt Full Thread M6x...

Страница 23: ... Standard SAF 1500 Filter Section 3 Scanner NO DESCRIPTION QTY 1 SUCTION SCANNER SAF 1500 SS316L F SCANNER DW 1 2 SUCTION SCANNER SHAFT SAF 1500 SS316 DW 1 3 PIN FOR SHAFT SAF 1500 35X5 S ST 1 4 PLUG 8MM SAF POM F SCANNER 1 5 NOZZLE SAF 1500 POM SCANNER 2 ...

Страница 24: ...chined 1 2 Suction Scanner Shaft SAF 1500 1 3 SLN Body SAF 3000 1500 2 4 Spring Loaded Nozzle Seal SAF Blue 4 5 SLN Tightening Nut SAF 4500 3000 2 6 SLN Cap SAF 3000 45000 2 7 SLN Spring Seat SAF 3000 4500 2 8 Spring Loaded Nozz Spring SAF 3000 4500 2 9 O RING Seal 2 016 NBR 2 10 Plug Threaded M8 for SAF 6000 PRO 1 11 Connecting pin 35x5 shaft to scanner 1 ...

Страница 25: ... of Amiad 8 This Warranty will not apply to damaged or defective products resulting from or related to i Fire flood power surges or failures or any other catastrophe and or unforeseen occurrence such as but not limited to those for which the Buyer is customarily insured for or any force majeure events ii Fault abuse or negligence of the Buyer iii Intake water not meeting the agreed standards as se...

Страница 26: ...D N Galil Elyon 1 1233500 Israel Tel 972 4690 9500 Fax 972 48141159 Email info amiad com Obelis s a Bd Général Wahis 53 1030 Brussels Belgium Tel 32 2732 5954 Fax 32 27326003 Email mail obelis net EC Declaration https www amiad com certificatesDownload asp ...

Отзывы: