background image

 

 

 

 

 

DISCOVER YOUR DIGITAL POTENTIAL 

S

PECIFICATIONS

 

 

I/O

 

 

Analog input x 4: 0-2.5V, 0-10V / 4-20mA (SW configurable) 

 

Digital input 

 

RS485 Half-Duplex 

Communication

 

 

4G LTE cellular cloud connectivity 

 

900MHz RF star-network configuration for multiple pumps 
connectivity 

 

BLE 

 

GPS  

Measurements

 

 

3-Axis vibration monitoring [Inch/Sec] 

 

Temperature ±5° [°F] 

 

Battery voltage [V] 

EDGE computing

 

 

Radial velocity RMS 

 

Axial velocity RMS 

 

3-Axis velocity FFT @ Five selected frequencies 

o

 

Where x = rotation freq. ex. 1x, 2x, 3x, 7x, 10x 

 

Rotation velocity [RPM] 

 

Operational hours 

Notifications 

 

 

Axis velocity RMS threshold cross 

 

Radial velocity RMS threshold cross 

 

Velocity amplitude threshold cross in any of the FFT selected 
frequencies 

 

Operational time threshold cross 

 

Temperature threshold cross 

 

Analog measurement threshold cross  

 

Digital input changes or flow frequency threshold cross 

Operation modes

 

 

Battery: 1 yr. @ 4 sample/hour and 2 cloud updates per day 

 

External DC power: 9..24VDC; up to 20 sample/hour and 8 cloud 
updates per day 

User interface

 

 

Internet browser 

 

Mobile apps: IoS and Android using BLE for on-site offline device 
connectivity  

Dimension & build

 

 

3.4”x3.4”x1.9” 

 

 

Robust glass filled PP enclosure IP65 comply 

 

Mounting screws 4x #8-32 x1 inch long 

Standards

 

 

FCC Part 15 (see label) 

 

RoHS comply 

Environmental conditions

 

 

Temperature: -22°F/+158°F 

 

 

 

Содержание VAPOR-C

Страница 1: ...AMI Global 6280 S Valley View 212 Las Vegas NV 89118 Phone 702 478 9700 Fax 702 478 9707 Website www amiglobal com DISCOVER YOUR DIGITAL POTENTIAL VAPOR C MANUAL SPECIFICATIONS VERSION 2 4 ...

Страница 2: ... STATEMENTS 3 FCC LABEL 4 SPECIFICATIONS 5 ASSEMBLY 6 DIMENSIONS 6 MOUNTING 7 WIRING 9 BATTERIES REPLACEMENT 11 Date Document Version Comments By 11 18 18 2 0 Created Ori Peled 11 26 18 2 2 Adding FCC label artwork Ori Peled 01 15 19 3 4 Update text Ori Peled ...

Страница 3: ...e following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device Cet appareil contient des émetteurs récepteurs exemptés de licence conformes aux RSS s d Innovation Sciences et Développement économique Canada Le fonctionnement est soumis aux deux conditions suivantes 1 Cet appareil...

Страница 4: ...DISCOVER YOUR DIGITAL POTENTIAL 4 FCC LABEL VERIZON CAT 1 MODEL FCC LABEL VERIZON CAT M MODEL FCC LABEL AT T T MOBILE CAT 1 MODEL ...

Страница 5: ... velocity RMS threshold cross Radial velocity RMS threshold cross Velocity amplitude threshold cross in any of the FFT selected frequencies Operational time threshold cross Temperature threshold cross Analog measurement threshold cross Digital input changes or flow frequency threshold cross Operation modes Battery 1 yr 4 sample hour and 2 cloud updates per day External DC power 9 24VDC up to 20 sa...

Страница 6: ...DISCOVER YOUR DIGITAL POTENTIAL 6 ASSEMBLY DIMENSIONS 73 66 2 9 Typ x4 3 4 3 4 1 9 ...

Страница 7: ... VAPOR C to the monitored equipment 9 64 Allen wrench If the device is used as a pump controller or communication gateway then there is no importance to the orientation however if also used for rotating equipment vibration monitoring then follow the below for the right orientation ...

Страница 8: ...DISCOVER YOUR DIGITAL POTENTIAL 8 Mounting orientation Mounting screws Radial X ...

Страница 9: ... you have access to the wire s terminal block Run the 6 wire cable through the cable gland in the bottom For water resistance environment use cable AMI part 400 0048 If other cable is used ensure cable outer diameter of 8mm and smooth cable jacket for proper sealing Connect the wires according to the wiring diagram below ...

Страница 10: ... YOUR DIGITAL POTENTIAL 10 Digital input wiring Signal Signal DIN GND DIN GND Open collector Dry contact 4 20mA Sensor 1 0 10V Sensor 4 I O are functional only when device is connected to external power supply ...

Страница 11: ...DISCOVER YOUR DIGITAL POTENTIAL 11 BATTERIES REPLACEMENT Use Energizer L91 Ultimate Lithium 3 x AA batteries ONLY ...

Отзывы: