MODEL 9 SERIES WELD HEAD
OPERATION MANUAL
5.0 ROTATION (SPEED) AUTO-CALIBRATION
(Contd.)
Note: Some larger Model 9 series weld heads provide access to the
calibration potentiometer through an access hole in the side of the
housing, adjacent to the potentiometer. A nylon screw is used to plug
this access hole. Removed it to gain access to the calibration
potentiometer. Replace this screw when calibration is complete.
Fig. 5
Model 9-1500
5.2
ROTATION (SPEED) MANUAL CALIBRATION
Some power supplies do not have auto calibration software. In this
case, the weld head motor is manually calibrated by creating a weld
program that should rotate the electrode 360 degrees. ie: 1 RPM for a
total of 60 seconds, 2 RPM for a total of 30 seconds, 3 RPM for
a total of 20 seconds, etc. Select a speed (RPM) and corresponding
time close to or equal to the speed that you intend on welding at to
achieve the most accurate calibration.
5.3 Calibration must be run in the “TEST” mode. Create a one level weld
schedule at your selected RPM. Amperage and pulse rate settings
may be set to any value, as during rotation calibration no arc will be
established. Set the rotation mode to “CONT” (continuous rotation).
Set rotation delay and downslope times to 0.0.