24
24
The minimum distance in front of the stove opening to combustible parts of the building
or interior decoration must be at least 1,1 m.
The dimension diagrams only show the minimum permitted installation distances for the
stove. When connecting to a steel flue, also note the safety distance requirements of the
flue. The safety distance between an un- insulated flue and a combustible part of the
building should be at least 450 mm.
A = height from floor to chimney connection upwards
B = height from floor to c/c chimney connection rear
C = height from floor to air inlet
D = height from floor to lower edge of hatch
E = minimum height to sloped ceiling from the centre of the chimney