OFF = Will prevent rotation from occurring.
CONT = Runs the travel at the PRIMARY-RPM speed only, regardless of PULSE
MODE.
STEP = Will pulse the travel between the PRIMARY-RPM and BACKGROUND-RPM
speed. If the TRAVEL MODE is in STEP but the PULSE MODE is in OFF then only
PRIMARY will occur (without pulsing there are no background functions).
8.
LEVEL 1 PRIMARY-RPM - After the Travel Start Delay time is complete the travel
function will begin. If the Level 1 Travel Mode is programmed to CONT the travel will be
rotating the arc at the Primary-RPM rate continuously regardless of any pulsing. If the
Travel Mode is STEP it will rotate the arc at the Primary-RPM speed each time the
system goes to PRIMARY.
9. LEVEL 1 BACKGROUND RPM - If the LEVEL 1 PULSE MODE is in ON or SYNC and
the TRAVEL MODE is in STEP the system will rotate the arc at the BACKGROUND-
RPM each time the system goes to a BACKGROUND pulse.
NOTE
Travel direction is programmable CLOCKWISE or COUNTER- CLOCKWISE. After the
Travel Start Delay the Head will rotate in the programmed direction. The direction is not
programmable
by
LEVELS.
10. LEVEL 1 PRIMARY WIRE - After the Wire Start Delay time is complete the Wire
Feeder will feed at the Primary Wire Feed value whenever the system is in Primary and
the Wire Mode is set to ON.
11. LEVEL 1 BACKGROUND WIRE - After the Wire Start Delay is complete the Wire
Feeder will feed at the Background Wire Feed value whenever the system is in
Background and the Wire Mode is ON.
12. LEVEL 1 AVC MODE - The AVC can be set in each Level to work
several
different
ways:
OFF = Will prevent the AVC servo from operating.
CONT = Allows the AVC to work continuously both in the PRIMARY and
BACKGROUND functions, using the Level 1 AVC value when in Primary and using the
Level 1 Background AVC value when in Background.
SAMP/PRI = Allows the AVC to work only during the PRIMARY current, using only the
Primary AVC value. The AVC position will not move during Background.
SAMP/BCK = Allows the AVC to work only during the BACKGROUND current, using
only the Background AVC value. The AVC position will not move during Primary.
13. LEVEL 1 PRIMARY AVC - After the AVC START DELAY time is complete and the AVC
MODE is in CONT or SAMP/PRI. the AVC will maintain this value during the Primary
current.
14. LEVEL 1 BACKGROUND AVC - After the AVC START DELAY time is complete and
the AVC MODE is in CONT or SAMP/BCK the AVC will maintain this value during the
Background
current.
15. LEVEL 1 OSCILLATOR AMPLITUDE - Is the distance the Torch
Oscillator will move from full IN to full OUT during the EXCURSION
TIME programmed in LEVEL 1.
16. LEVEL 1 OSCILLATOR EXCURSION TIME - The time in LEVEL
1 that the oscillator will travel from full IN to full OUT position.
Содержание 415
Страница 1: ...MODEL 415 OPERATION MANUAL Document No 740084 Revision N ...
Страница 19: ...Model 415 Operation Manual Document No 740084 Revision N 14 ...
Страница 24: ...Model 415 Operation Manual Document No 740084 Revision N 19 ...
Страница 25: ...Model 415 Operation Manual Document No 740084 Revision N 20 ...
Страница 34: ...Model 415 Operation Manual Document No 740084 Revision N 29 ...