1.6
Battery UPS KW914-B with the Sailor PSU (VDR)
Normal indications are:–
Green = Battery Trickle Charge (Normal)
NOTE:
When the system is not in use i.e. Docking Period you must switch of the
UPS internally to help prevent battery discharge.
1.7
Battery UPS KW914-C (SVDR)
Normal indications are:–
Red = Battery Trickle Charge (Normal)
NOTE:
When the system is not in use i.e. Docking Period you must switch of the
UPS internally to help prevent battery discharge.
2.
MEU TEXT DISPLAY and REMOTE ALARM
The Unit displays the status messages and will also indicate the reason for an alarm.
The remote unit will alert the Bridge staff with an audible ad visual alarm. The audible
alarm can be muted from the Remote unit.
Status messages indicate the status and reason for an alarm.
M3 Messages under normal operation.
Process Line:
INITIALISING FA:FA
(System Starting)
RECORDING HH:MM
(System Recording to Capsule and Time UTC)
RADAR PICTURE SAVED
(Radar Frame Grab Successfully Saved)
AUDIO FILE SAVED
(Audio File Successfully Saved)
NMEA DATA FILE SAVED
(NMEA File Successfully Saved)
AIS / EXP DATA SAVED
(AIS / Expansion Port Data File Successfully Saved)
Status Line:
VDR TIME HH:MM
(VDR System Time as set by UTC)
AC POWER STATUS OK
(AC Power is Present and OK)
DC INPUT VOLTS OK
(DC Volts is Nominal. OK)
NO ALARMS ACTIVE
(There are No System Alarms Present)
MIC TESTS OK 111 111
(Mics 123 456 have Tested OK)
MEASURING AUDIO LEVL
(Measuring Audio Levels for Groups 1 & 2)
AUDIO LEVEL OK ## %
(Result of the Audio Levels Test)
CAPSULE COMMS OK
(Communications with Capsule Successful)
GPS DATE & TIME RCVD
(GPS data is Present and OK)
EP COMMS OK
(Communications from the Embedded Processor Successful)