16
I. Installing the limit switch control bar and limit switch
(See Fig. 25).
Limit switch
connected
with cable
Fig. 25
Limit switch cable wiring
Connect the brown wire
to the terminal 12# on
limit switch and terminal
4# on control button.
Connect the blue wire
to terminal 11# on
limit switch and
terminal A1 on AC
contactor of power unit
Adjust drive rod of limit
switch
Connect the yellow and
green wire to the earth
wire terminal on limit
switch and the earth wire
terminal of power unit.
68
34
33
29
34
35
Loosen screw of drive
rod for adjustment
Содержание OHX-10
Страница 1: ...TWO POST LIFT Model OHX 10 OHX 10H Original...
Страница 5: ...3 Arm Swings View Car in Fig 3...
Страница 6: ...4 Swing and extending the arms to the lifting point of vehicle Fig 4...
Страница 19: ...17 I Lift the carriages up and make them be locked at the same level See Fig 26 Fig 26...
Страница 25: ...23 M Install safety cable See Fig 32 Fig 32 Wearing wire cable A side B side 25 25 86 7...
Страница 34: ...32 IV EXPLODED VIEW OHX 10 Fig 46...
Страница 35: ...33 OHX 10H Fig 47...
Страница 41: ...39 5 Power unit 071101 explosive view single phase 220V 60HZ Fig 52...