AMG6184-DR-SF Instruction Sheet
D18236-01.doc

Connections

Video Output Connections

No. of channels.................................... 8
Connectors .......................................... 75 ohm BNC Socket.
Output Impedance............................... 75 ohm terminated.
Output Level ........................................ 1 Volt p-p nominal
Frequency Response .......................... 10Hz to 7MHz.

Optical Connections

PRIMARY OPTO OUT

Connector ............................................ LC/PC
Primary Optical Launch Power............ -5dBm
Wavelength.......................................... 1550nm
Secondary Optical Sensitivity.............. -22dBm
Wavelength.......................................... 1310nm

PRIMARY OPTO IN

Connector ............................................ LC/PC
Primary Optical Sensitivity................... -22dBm
Wavelength.......................................... 1550nm
Secondary Optical Launch Power ....... -5dBm
Wavelength.......................................... 1310nm

Power Connection

Connector Type ................................... 2.1mm screw lock long power jack – centre positive
Connector Partno. ............................... Switchcraft S761K, AMG G16125-00
Supply Voltage .................................... 13.5 to 18.0 Volts DC.
Maximum Power ................................. 10 Watts

Data and Audio Channel Connections

DATA CHANNEL A

Data Channel A ................................... 1 channel
Data Connector ................................... RJ45

Channel A Interface

On Board Data Interface – RS232, RS422 or RS485. Selected by slide switch

above RJ45 connector.

RS485 – switch position - high (closest to BNC connections)
RS422 – switch position – middle
RS232 – switch position – low (furthest from BNC connections)

DATA CHANNEL B

Data Channel B ................................... Not Present

Содержание AMG6184-DR-SF

Страница 1: ...and transmit receives one bi directional data channel to from a singlemode optical fibre ring with Dual Redundant operation In addition LED diagnostics is inherent within each unit to enable easy ide...

Страница 2: ...onnections 5 Optical Connections 5 Power Connection 5 Data and Audio Channel Connections 5 Data and Audio Channel Configuration 6 Data and Audio Channel Configuration 6 Data Interface Connections Chan...

Страница 3: ...rom the previous insert unit and those video signals will be lost The switch channel numbers 1 to 8 correspond to video channels 1 8 Unused switch channel numbers 0 9 duplicate video channel selection...

Страница 4: ...four channel insert units respectively can be combined to make up an 8 channel video transmission system as illustrated below If a fibre link is broken operation of the ring continues by making use o...

Страница 5: ...sitivity 22dBm Wavelength 1310nm PRIMARY OPTO IN Connector LC PC Primary Optical Sensitivity 22dBm Wavelength 1550nm Secondary Optical Launch Power 5dBm Wavelength 1310nm Power Connection Connector Ty...

Страница 6: ...above the RJ45 connector The switch signifies the presence of the X16004 Low Speed Data Audio Interface Board If there are LED s present on the RJ45 connector then an X16003 Ethernet Interface Board...

Страница 7: ...ng Off not transmitting Secondary Opto Sync RX Green optical channel receiving Org receiving but not synchronised Red receiving but fault on a previous unit Off not receiving See appropriate section o...

Страница 8: ...e received optical signal The number of red LED flashes is a count which indicates the number of working units between itself and the optical fault In the case of a complete failure of the Receive Uni...

Страница 9: ...al channels a At insert unit Tx1 the Pri Rx LED flashes once indicating a Primary Rx fault in the direction of Tx2 1 unit away The Sec Rx LED flashes twice indicating a Secondary Rx fault in the direc...

Страница 10: ...panel and slide the PCB s out of the case Ensure that the fibres do not snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the approp...

Страница 11: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 11 of 12 AMG6184 DR SF Instruction Sheet D18236 01...

Страница 12: ...make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 12 of 12 AMG6184 DR SF Instruction Sheet D18236 01...

Отзывы: