![AMG AMG5616 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/amg/amg5616/amg5616_instruction-manual_2931933006.webp)
AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.
Page 6 of 8
AMG5616 Instruction Sheet D17084-
02.doc
The system detects a tri-state input condition on the data channel bus when in RS-485 or RS-422
mode.
Data Interface Connections
Data Channel
Connector
Pin No.
RS-485
[switch top]
RS-422
[switch middle]
RS-232
[switch bottom]
1
IN + (A)
IN
2
IN - (B)
3
GND
GND
GND
4
5
6
7
IN/OUT + (A)
OUT + (A)
8
IN/OUT - (B)
OUT - (B)
OUT
Note: (A) or (B) in brackets in the above table refers to RS-485 / RS-422 data specification.
Alarm Channel Configuration
The
AMG5616
provides 2 uni-directional alarm outputs.
Each alarm output uses a solid-state relay, maximum current 150mA at 125Vac/dc and Ron < 6.5
Ω
.
Alarm Output 1
: Provides a pair of normally open, volt-free contacts.
Alarm Output 2
: Provides a normally open, switched contact to Ground (0V / GND).
Alarm Interface Connections
Alarm Interface
Connector Pin
No.
Alarm 1
Alarm 2
1
2
3
ALARM 2 GND
4
ALARM 2 OUT +
5
ALARM 1 OUT -
6
ALARM 1 OUT +
7
8