AMG AMG5614 Скачать руководство пользователя страница 1

AMG Systems Ltd. reserves the right to make changes to this
document without notice. The information herein is believed to
be accurate. No responsibility is assumed by AMG for its use.

Page 1 of 8

AMG5614 Instruction Sheet D17081-
03.doc

AMG5614

Instruction Manual

Single Channel Video Receive Unit with one Bi-directional

Data Channel and one Bi-directional Alarm for a Multimode

Fibre Link

The

AMG5614

is a standalone system designed to receive one video signal and transmit and receive

one bi-directional alarm plus one data signal over a Multimode optical fibre.

The

AMG5614

is designed to be powered using an

AMG2001

standalone power supply.

The

AMG5614

is designed to operate with an

AMG5613

standalone video transmit unit in a point to

point configuration.

Содержание AMG5614

Страница 1: ...eo Receive Unit with one Bi directional Data Channel and one Bi directional Alarm for a Multimode Fibre Link The AMG5614 is a standalone system designed to receive one video signal and transmit and re...

Страница 2: ...nnection 3 Connections 4 Video Output Connection 4 Optical Connections Multimode 4 Power Connection 4 Data and Alarm Channel Connections 4 Data and Alarm Channel Configuration 5 Data Channel Configura...

Страница 3: ...03 doc Introduction Unit Functional Schematic The AMG5614 receives 1 video signal plus 1 data and 1 bi directional alarm signal from a AMG5613 transmit unit It also transmits 1 data and 1 bi direction...

Страница 4: ...ptical fibre The optical data rate is 155Mbits s which may restrict operation to a maximum fibre length of 7km although in most cases the units will operate successfully over longer fibre lengths It i...

Страница 5: ...shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 422 modes detects a tri state input condition by monitoring the differe...

Страница 6: ...above table refers to RS 485 RS 422 data specification Alarm Channel Configuration The AMG5614 provides one bi directional alarm output contact closure input The alarm input is typically connected to...

Страница 7: ...no connection on IN IN Data Present IN RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals bei...

Страница 8: ...ng screws on the rear panel and slide the PCB sufficiently out of the case to enable access to the switch To replace the PCB into the case slide the PCB gently into the case if necessary aligning the...

Отзывы: