AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 5 of 8 

AMG5514R Instruction Sheet D17366-
00.doc 
 

 

 

Front Panel Indicators 

Power / Opto LED 

Power / Opto ........................................ Green 

Unit  powered, Opto sync. 

  Red 

Unit powered, no Opto sync. 

 

  Off 

No power applied to unit 

   

 

Low Speed Data LEDs 

Data Present IN (RS485 or RS422) .... Green 

logic zero  (+V, -V) present on IN+, IN- 

  Red 

logic one (-V,V+) present on IN+, IN- 

  Off 

tri-state off or no connection on IN+, IN- 

 
Data Present IN (RS232) .................... Green 

logic  zero  (+V) present on input IN+ 

  Red 

logic transitions present on input IN+ 

  Off 

logic one (-V) present on input IN+ 

 
IN corresponds to the data signals being transmitted onto the optical fibre. 
 
Data Present OUT (RS485 or RS422) Green 

logic zero (+V,-V) present on OUT+, OUT- 

  Red 

logic one (-V,+V) present on OUT+, OUT- 

  Off 

tri-state off or no connection on OUT+, OUT- 

 
Data Present OUT (RS232) ................ Green 

logic zero (+V) present on OUT+ 

  Red 

logic transitions present on OUT+ 

  Off 

logic one (-V) present on OUT+ 

 
OUT corresponds to the data signals being received from the optical fibre. 
 

 

Alarm LEDs 

ALARM IN ............................................ Green 

Alarm  ON  / Contacts closed. 

  Off  

Alarm OFF / Contacts open. 

 
ALARM OUT ........................................ Green 

Alarm  ON  / Contacts closed. 

  Off  

Alarm OFF / Contacts open. 

 

Содержание AMG5514R

Страница 1: ...ata Channel and one Bi directional Alarm for a Singlemode Fibre Link The AMG5514R is a rackmount receive unit designed to transmit and receive 1 data signal plus 1 Bi directional alarm over one Single...

Страница 2: ...ctional Schematic 3 Optical Connection 3 Connections 4 Optical Connections Singlemode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data...

Страница 3: ...ion Unit Functional Schematic The AMG5514R transmits 1 data channel and 1 uni directional alarm signal to the AMG5513 transmit unit It also receives 1 data channel and 1 Bi directional alarm transmitt...

Страница 4: ...mum Optical Dynamic Range 20dB Power Connection Power supply From plug in connection on the AMG2009 or AMG2015 subrack Power consumption 3 0 Watts max Data and Alarm Channel Connections No of Data Cha...

Страница 5: ...n on IN IN Data Present IN RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitt...

Страница 6: ...e the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data input for both the RS 485 and the RS 422 modes detects a tri state inp...

Страница 7: ...IN OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Channel Configuration The AMG5514R provides one bi directional alarm output contact clos...

Страница 8: ...practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces or point them at other peo...