AMG AMG4714Bx-SF Скачать руководство пользователя страница 9

AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 9 of 12 

AMG4714Bx-SF Instruction Sheet 
D32036-00.doc 
 

 

 

Physical Information 

Dimensions 

Height .................................................. 112mm 
Width ................................................... 170mm (excluding connectors) 
Depth ................................................... 35mm 
Weight ................................................. 750grams 
 

 

Mounting Details 

The AMG unit is supplied with a clip-on mounting bracket which should be attached to a panel or wall 
using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the 
mounting bracket, and is then held firmly in position. 
 

 

Removal / replacement from / to the Case 

Note: - The AMG unit PCB's are static sensitive. Handle with proper care and use normal electrostatic 
discharge (ESD) procedures. Use properly grounded protection (for example, wrist straps) when 
handling the PCB.  
 
To remove units from the case to access the data expansion boards and the daughter boards, remove 
the 2 or 4 fixing screws on the rear panel and slide the PCB's out of the case.  
Ensure that the fibres do not snag or get trapped.  
 
To replace the PCB's into the case, slide the PCB's gently into the case aligning the boards with the 
appropriate slots. Ensure that the fibre do not snag or get trapped. 
 
 

 

Safety 

AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000. 
 
It is always advisable to follow good practice when working with optical fibre systems. This includes: 
 

 

Do not stare with unprotected eyes or with any unapproved collimating device at fibre 

ends or connector faces, or point them at other people. 

 

Use only approved filtered or attenuating viewing aids 

 
For other safety issues and advice on good practice associated with optical fibre systems, please see 
EN 60825-2:2000 or your local safety officer. 
 

 

Maintenance and Repair 

There are no user serviceable parts within AMG products. See unit data sheet for full specification. 
In case of problem or failure, please call your local support centre or contact:  

AMG Systems Ltd.

 at  

3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK. 
 
 

Phone    

 

+44 (0) 1767 600 777 

 

Technical Support  

+44 (0) 1767 604 491  

 

Email    

 

[email protected] 

 

Содержание AMG4714Bx-SF

Страница 1: ...up to 2 Bi directional Data and Audio Channels for a Singlemode Fibre Link The AMG4714Bx SF is a standalone four channel video receive unit designed to receive 1 video signal and transmit and receive...

Страница 2: ...tions 4 Power Connection 4 Data and Audio Channel Connections 4 Data and Audio Channel Configuration 5 Data and Audio Channel Configuration 5 Data Interface Connections Channel A 5 Data Channel A Conf...

Страница 3: ...2 AMG4714Bx SF Instruction Sheet D32036 00 doc Introduction Unit Functional Schematic The AMG4714Bx SF receives up to 1 video and 2 data signals from the AMG4713Bx SF It also transmits 2 data signal t...

Страница 4: ...Wavelength 1550nm Power Connection Connector Type 2 1mm screw lock long power jack centre positive Connector Partno Switchcraft S761K AMG G16125 00 Supply Voltage 13 5 to 18 0 Volts DC Maximum Power 1...

Страница 5: ...f duplex two wire interface depending on the position of the switch located above the RJ45 connector The switch signifies the presence of the X16004 Low Speed Data Audio Interface Board If there are L...

Страница 6: ...r Board 1 X04057 RS422 485 Data Interface Daughter Board 2 X04049 RS232 Data Interface Daughter Board 3 X04058 20mA Current Loop Data Interface Daughter Board 4 X12579 TTL Data Interface Daughter Boar...

Страница 7: ...resent on IN IN Off tri state off or no connection on IN IN Data Present TX RS232 Green logic zero V present on input IN Red logic transitions present on input IN Off logic one V present on input IN T...

Страница 8: ...ing transmitted on the optical fibre Data Present RX Green logic zero V V present on OUT OUT Red logic transitions present on OUT OUT Off logic one V V present on OUT OUT This represents the data sign...

Страница 9: ...panel and slide the PCB s out of the case Ensure that the fibres do not snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the appropr...

Страница 10: ...o make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 10 of 12 AMG4714Bx SF Instruction Sheet D32036 00...

Страница 11: ...o make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 11 of 12 AMG4714Bx SF Instruction Sheet D32036 00...

Страница 12: ...o make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 12 of 12 AMG4714Bx SF Instruction Sheet D32036 00...

Отзывы: