Physical Information 

Dimensions 

Height................................................... 112mm 
Width .................................................... 170mm (excluding connectors) 
Depth ................................................... 70mm 
Weight .................................................. 1000grams 
 

 

Mounting Details 

The AMG unit is supplied with a clip-on mounting bracket which should be attached to a panel or wall 
using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the 
mounting bracket, and is then held firmly in position. 
 

 

Removal / replacement from / to the Case 

Note: - The AMG unit PCB's are static sensitive. Handle with proper care and use normal electrostatic 
discharge (ESD) procedures. Use properly grounded protection (for example, wrist straps) when 
handling the PCB.  
 
To remove units from the case to access the data expansion boards and the daughter boards, remove 
the 2 or 4 fixing screws on the rear panel and slide the PCB's out of the case.  
Ensure that the fibres do not snag or get trapped.  
 
To replace the PCB's into the case, slide the PCB's gently into the case aligning the boards with the 
appropriate slots. Ensure that the fibre do not snag or get trapped. 
 
 

 

Safety 

AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000. 
 
It is always advisable to follow good practice when working with optical fibre systems. This includes: 
 

 

Do not stare with unprotected eyes or with any unapproved collimating device at fibre 

ends or connector faces, or point them at other people. 

 

Use only approved filtered or attenuating viewing aids 

 
For other safety issues and advice on good practice associated with optical fibre systems, please see 
EN 60825-2:2000 or your local safety officer. 
 

 

Maintenance and Repair 

There are no user serviceable parts within AMG products. See unit data sheet for full specification. 
In case of problem or failure, please call your local support centre or contact:  

AMG Systems Ltd.

 at  

3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK. 
 
 

Phone    

 

+44 (0) 1767 600 777 

 

Technical Support  

+44 (0) 1767 604 491  

 

Email    

 

[email protected] 

 

Содержание AMG4681-1550-C

Страница 1: ...t unit designed to transmit 8 video signals to an AMG4682 1550 C or rackmount equivalent AMG4682R 1550 C 8 channel receiver It requires one Multimode optical fibre for the transmission of the video It...

Страница 2: ...1 1550 C Instruction Sheet D18980 00 doc Contents Introduction 3 Unit Functional Schematic 3 Optical Connection 3 Connections 4 Video Input Connections 4 Optical Connections 4 Power Connection 4 Front...

Страница 3: ...ntroduction Unit Functional Schematic The AMG4681 1550 C transmits up to 8 video signals to a AMG4682 1550 C It incorporates a 1550nm 1310nm wavelength division multiplexer This allows the user to com...

Страница 4: ...ary Optical Launch Power 6dBm Wavelength 1550nm 1310nm Optical Fibre Multimode 50 125 or 62 5 125 PRIMARY OPTO IN 1310nm signal input Connector LC PC Wavelength 1310nm Optical Fibre Multimode 50 125 o...

Страница 5: ...G4681 1550 C Instruction Sheet D18980 00 doc Front Panel Indicators Power LED Power Green unit powered Off no power applied to unit Video Input LED s Video Present CH1 8 Green video signal present on...

Страница 6: ...panel and slide the PCB s out of the case Ensure that the fibres do not snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the approp...

Страница 7: ...o make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 7 of 8 AMG4681 1550 C Instruction Sheet D18980 00...

Страница 8: ...o make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 8 of 8 AMG4681 1550 C Instruction Sheet D18980 00...

Отзывы: