AMG3788ERN-DR-1550-HP
Instruction Sheet D16678-00

Management Port Pinout

Pin Number

RS232 Connection

RS485 Connection

1

-

Data B (-)

2

RD (data out of
port)

Data A (+)

3

TD (data into port)

-

4

Connect to DTR
held –ve or short to
ground

-

5

SG (signal ground)

SG (signal Ground)

6

Alarm Output

Alarm Output

7

Alarm Output

Alarm Output

8

Alarm reset (Gnd)

Alarm reset (Gnd)

9

Alarm reset

Alarm reset

For multiple Management Ports it is recommended that the RS485 interface is used with each RS485 pair
connected in parallel. In this case a RS485 to RS232 converter is required in order to connect to a normal
PC Comm Port.

The time delay between receiving a data request and sending out a response from the port is 625us.
Therefore any RS232 or R S485 converter should have a ‘turn around’ time or ‘transmit dwell’ time equal to
or less than 625us.

A suitable converter is the

Dataforth DCP485-S

(Available in the UK Farnell, Pt. No 300-9348)

On

DCP485-S

RS485 Switch Settings:
1-UP, 2-DOWN, 3-DOWN, 4-UP, 5-DOWN, 6-DOWN, 7-DOWN, 8-UP

RS232 Switch Settings
1-DOWN, 2-UP, 3-DOWN, 4-UP

DCE/DTE set to DCE.

Connections to management port:

DCP485-S

Management Port

1

N/C

2

1

3

2

4

1

5

2

NOTE: on the DCP485-S pin 5 and pin 3 are connected together and pin4 and pin 2 connected together.

Alarm Output and Reset Operation

The alarm output and reset is designed to indicate a change of state of the fibre loop or spur attached to the
receiver. The Alarm output is a volts free contact relay output (rating: 0.5amp at 125VAC or 1amp at
24VDC). It normally open, which means that when not powered the contacts will be open circuit. On power
up the contacts will close and will remain closed for up to 5 seconds. During this time the receiver will
monitor and record the state of the 3700 units connected to the receiver. The contacts will then remain
closed until there is a change from this recorded state. A change of state would be:

1.

addition or loss of video at any insert node

2.

addition or loss of primary optical input at any node

3.

addition or loss of secondary optical input at any node

4.

power up or down of any node

5.

loss of power at the receiver

Содержание AMG3787E-1-DR-1550-HP

Страница 1: ...into an AMG2000 or an AMG2005 subrack which in turn fits into a 19 rack system It also includes an AMG Network Management Interface to allow management of the system using the AMG SNMP enabled management software The AMG3788ERN DR 1550 HP is designed to operate with the AMG3787E 1 DR 1550 HP AMG3787E 2 DR 1550 HP AMG3787E 4 DR 1550 HP and AMG3787E 8 DR 1550 HP single channel dual channel four chan...

Страница 2: ...tions 4 Power Connections 5 Ethernet Connections 5 Data Connections 5 Management Port Connections 5 Data and Audio Channel Configuration 6 Data and Audio Daughter Board Fitting Instructions 6 Data and Audio Connections 7 Front panel Indicators 8 Power LED 8 Fibre Optic LED s 8 Video LED s 8 Ethernet Data LED s 8 Data Connections 8 Ethernet Operation 10 Physical Information 10 Dimensions 10 Mountin...

Страница 3: ...E 1 DR 1550 HP AMG3787E 2 DR 1550 HP and AMG3787E 4 DR 1550 HP single dual and four channel insert units respectively can be combined to make up an 8 channel video transmission system as illustrated below with an AMG3788ERN DR 1550 HP receiver As each unit regenerates the optical signal the optical dynamic range between each optically connected node is 22dB 3788ERN DR 1550 HP 3700 optics Primary 1...

Страница 4: ...VIDEO INSERT BI DIRECTIONAL DATA TX O O R X OPTOSYNC FRONT PANEL INDIC ATORS VIDEO PRESENT CH1 O O CH2 CH3 O O CH4 POWER O GND 12 16 Volts dc OPTO IN VIDEO CH1 VIDEO CH 2 VIDEO CH3 VIDEO CH 4 OPTO OUT GND OUT OUT IN IN DATA CONNECTIONS INTE RNAL RS422 485 S W ITCHABLE TX O O R X DATA PRESENT 1 3 8 2 1 6 8 3 2 4 7 5 Primary Optical Route Secondary Optical Route OPTO PRESENT PRIMARY SECONDARY VIDEO ...

Страница 5: ...power level 5dBm of the AMG3787E 1 DR 1550 HP and AMG3788ERN DR 1550 HP is higher than the maximum optical input power level 0dBm there should always be at least 5dB of optical attenuation between two units in order to prevent an overload of the optical inputs Power Connection Power supply from plug in connection on the 2000 or 2005 subrack Power consumption 15 Watts max Ethernet Connections No of...

Страница 6: ...d be fitted in the appropriate data channel slots on the data expansion boards Each data interface board enables one bi directional channel The data interface daughter board options are as follows Option Code Part No Description 1 X04057 RS422 485 Data Interface Daughter Board 2 X04049 RS232 Data Interface Daughter Board 3 X04058 20mA Current Loop Data Interface Daughter Board 4 X04059 TTL Data In...

Страница 7: ...N A B 16 AUDIO DATA CH7 IN A B 17 AUDIO DATA CH7 IN A B 18 AUDIO DATA CH8 IN A B 19 AUDIO DATA CH8 IN A B Pin No Description Bank 20 AUDIO DATA CH1 OUT A B 21 AUDIO DATA CH1 OUT A B 22 AUDIO DATA CH2 OUT A B 23 AUDIO DATA CH2 OUT A B 24 AUDIO DATA CH3 OUT A B 25 AUDIO DATA CH3 OUT A B 26 AUDIO DATA CH4 OUT A B 27 AUDIO DATA CH4 OUT A B 28 GND 29 GND 30 AUDIO DATA CH5 OUT A B 31 AUDIO DATA CH5 OUT ...

Страница 8: ...deo signal present on output BNC Red Green channel present but no video present on output BNC Off no video channel present Ethernet Data LED s BANK A Data Present TX Ethernet Green data present on the Ethernet input Off no data present on the Ethernet input This represents the Ethernet signals being transmitted onto the optical fibre Data Present RX Ethernet Green data present on the Ethernet inpu...

Страница 9: ...input 600ohm This represents the audio signals being transmitted on the optical fibre BANK B When data daughter board fitted Data Present CH1 8 TX Green logic one present on the data input Red logic zero present on the data input Off tri state off or no connection on the data input This represents the data signals being transmitted on the optical fibre Data Present CH1 8 RX Green logic one present...

Страница 10: ...it rather than all ports as when operating at 100Mbits s full duplex The 100baseT port does not implement MDI MDIX it should be connected with a straight though cable to an external switch port and with a cross over cable when connected directly to a PC or DTE Physical Information Dimensions Height 3U Plug in Width 21HP Depth 172mm excluding connectors Weight 1200grams Mounting Details The unit is...

Страница 11: ...aforth DCP485 S Available in the UK Farnell Pt No 300 9348 On DCP485 S RS485 Switch Settings 1 UP 2 DOWN 3 DOWN 4 UP 5 DOWN 6 DOWN 7 DOWN 8 UP RS232 Switch Settings 1 DOWN 2 UP 3 DOWN 4 UP DCE DTE set to DCE Connections to management port DCP485 S Management Port 1 N C 2 1 3 2 4 1 5 2 NOTE on the DCP485 S pin 5 and pin 3 are connected together and pin4 and pin 2 connected together Alarm Output and...

Страница 12: ...osed state until the next change of state to the 3700 system connected to the receiver The alarm output may not register a change of state which happens within 5 seconds of release of the alarm reset Safety The 3700 series of products uses a Class 1 laser system in accordance with EN 60825 2 2000 It is always advisable to follow good practice when working with optical fibre systems This includes D...

Отзывы: