AMG AMG3782ERN Скачать руководство пользователя страница 8

AMG Systems Ltd. reserves the right to make changes to this 
document without notice. The information herein is believed to 
be accurate. No responsibility is assumed by AMG for its use.  

Page 8 of 12 

AMG3782ERN Instruction Sheet 
D18979-00.doc 
 

 

 

Each management interface, thus each receiver or transmitter, has an ID number with is identified 
below the management port. This ID number is used by the AMG Network Management System 
(NMS) to identify the unit. 
 
The physical interface is a 9 way female D-type connector. It supports either RS-232 or RS-485. 
 

Management Port Pin-out:

 

 

Pin Number  RS-232 Connection 

RS-485 Connection 

Data B (+) 

RD (data out of port) 

Data A (-) 

TD (data into port) 

Connect to DTR held –ve or shorted 
to ground 

SG (signal ground) 

SG (signal Ground) 

Alarm Output  

Alarm Output 

Alarm Output 

Alarm Output 

Alarm reset (Gnd) 

Alarm reset (Gnd) 

Alarm reset 

Alarm reset 

 
For multiple Management Ports it is recommended that the RS-485 interface is used with each RS-
485 pair connected in parallel. In this case an RS-485 to RS-232 / USB converter is required in order 
to connect to a standard PC Comms. Port. 
 
The time delay between receiving a data request and sending out a response from the port is 625µs. 
Therefore any RS-485 converter should have a 'turn around' time or 'transmit dwell' time equal to or 
less than 625µs.   
 

Recommended RS-485 Converter's are:

 

 
RS-485 to RS-232 
Dataforth DCP485-S: Available in the UK from http://uk.farnell.com/  Order No. 300-9348 
 

Settings on the DCP485-S:

 

 

RS-485 Switch Settings: 1-UP, 2-DOWN, 3-DOWN, 4-UP, 5-DOWN, 6-DOWN, 7-DOWN, 

8-UP 

 

RS-232 Switch Settings: 1-DOWN, 2-UP, 3-DOWN, 4-UP 

 

DCE/DTE set to DCE. 

 
RS-485 to USB 
B&B 485USBTB-2W: Available in Europe from http://www.bb-europe.com/ Order No. 485USBTB-2W 
 

Connections to management port:

 

 

Management 

Port 

DCP485-S 

485USBTB-2W 

2 or 4 

B+ 

3 or 5 

A- 

GND 

GND 

 
NOTES:  
On the DCP485-S, pins 3 and 5 are connected together and pins 2 and 4 are connected together.  
On the 485USBTB-2W, there are 2 pairs of terminals both labeled A-, B+, either pair may be used. 
 
 
 
 
 

 

Содержание AMG3782ERN

Страница 1: ...00BaseT Ethernet connectivity around the ring The AMG3782ERN is designed to plug into an AMG2005 or AMG2009 subrack which in turn fits into a 19 rack system It also includes an AMG Management Interfac...

Страница 2: ...tical Connection 3 Connections 4 Video Output Connections 4 Optical Connections 4 Power Connection 4 Ethernet Connection 4 Front Panel Indicators 5 Power LED 5 Video Output LED s 5 Fibre Optic LED s 5...

Страница 3: ...MG3741ER insert unit video signals present at the BNC inputs can be inserted on one to eight video channels transmitted on the optical fibre The first video channel number of each insert unit is set b...

Страница 4: ...t p p nominal Frequency Response 10Hz to 7MHz Optical Connections PRIMARY OPTO OUT Connector LC PC Primary Optical Launch Power 5dBm Wavelength 1310nm Optical Fibre Singlemode PRIMARY OPTO IN Connecto...

Страница 5: ...optical channel receiving Org optical channel receiving but not sync Off optical channel not transmitting Low Speed Data LEDs Ethernet Data LED s BANK A Data Present TX Ethernet Green data present on...

Страница 6: ...when Ethernet only or 50MBit s when the low speed data option is also used If one node is transmitting the entire bandwidth is available for this traffic If multiple nodes transmit simultaneously on t...

Страница 7: ...h Rx or Tx RS 232 or RS 485 on Management Port Multiple Rx Tx units use RS 485 and effectively parallel all the RS 485 ports together Connect to PC RS 232 Port via RS 485 RS 232 convertor Proprietary...

Страница 8: ...is recommended that the RS 485 interface is used with each RS 485 pair connected in parallel In this case an RS 485 to RS 232 USB converter is required in order to connect to a standard PC Comms Port...

Страница 9: ...from this recorded state A change of state would be Addition or loss of video at any insert node Addition or loss of primary optical input at any node Addition or loss of secondary optical input at a...

Страница 10: ...snag or get trapped To replace the PCB s into the case slide the PCB s gently into the case aligning the boards with the appropriate slots Ensure that the fibre do not snag or get trapped Safety AMG O...

Страница 11: ...to make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 11 of 12 AMG3782ERN Instruction Sheet D18979 00 d...

Страница 12: ...to make changes to this document without notice The information herein is believed to be accurate No responsibility is assumed by AMG for its use Page 12 of 12 AMG3782ERN Instruction Sheet D18979 00 d...

Отзывы: