AMG AMG2684 Скачать руководство пользователя страница 3

AMG Systems Ltd. reserves the right to make changes to this document without
notice. The information herein is believed to be accurate. No responsibility is
assumed by AMG for its use.

Page 3 of 7

AMG2684 Instruction
Sheet D15700-00

Power Connection

Connector ............................................removable screw terminal connector (3.5mm spacing)

Manufacturers Part No. Phoenix/Combicom MC1-5/2-ST-3.5
AMG Part No.G00047-00

Power requirement .............................. 12 volts to 16 volt DC @

700mA (1 amp turn on
current)

Connections......................................... See schematic

+12 – 16 Volts on lower pin
0 Volts on upper pin

Data Connections

Number of Channels............................ Two independent data channels, one associated with video

channels 1-4 and another associated with video channels 5-8.

Data Connector ................................... 5 way removable spring terminal connector (2.5mm spacing)

Manufacturers Part No. Phoenix/Combicom FK-MC-0.5/5-ST-
2.5
AMG Part No G15098-00

SW1 used to select between RS232 and RS485/422, SW2 is used to select between RS422 and

RS485.

NOTE: The unit is shipped from the factory as RS485 unless otherwise requested.

Connections RS422 4 wire .................. See schematic

Connections RS485 2 wire .................. See schematic

Connections RS232 ............................. See schematic

OPTO IN

D
A
T
A

CH 8

CH 4

OPTO OUT

Channels 1 to 4
Power
Ground
+12 – 16 Volts dc

D
A
T
A

Channels 5 to 8

Power

Ground

+12 – 16 Volts dc


OPTO IN

D
A
T
A

CH 8

CH 4

OPTO OUT

Channels 1 to 4
Pin 5 – Ground
Pin 4 – Data Out –
Pin 3 – Data Out +
Pin 2 – Data In –
Pin 1 – Data In +



Channels 5 to 8
Pin 5 – Ground
Pin 4 – Data Out –
Pin 3 – Data Out +
Pin 2 – Data In –
Pin 1 – Data In +

D
A
T
A

OPTO IN

D
A

T
A

CH 8

CH 4

OPTO OUT

Channels 1 to 4
Pin 5 – Ground
Pin 4 – No Connection
Pin 3 – No Connection
Pin 2 – Data In/Out –
Pin 1 – Data In/Out +


D

A
T
A

Channels 1 to 4
Pin 5 – Ground
Pin 4 – No Connection
Pin 3 – No Connection
Pin 2 – Data In/Out –
Pin 1 – Data In/Out +

OPTO IN

D
A
T
A

CH 8

CH 4

OPTO OUT

Channels 1 to 4
Pin 5 – Ground
Pin 4 – No Connection
Pin 3 – Data Out

Pin 2 – No Connection –
Pin 1 – Data In

A

A

Channels 1 to 4
Pin 5 – Ground
Pin 4 – No Connection
Pin 3 – Data Out
Pin 2 – No Connection

Pin 1 – Data In

Содержание AMG2684

Страница 1: ...operation of the video and bi directional data Index Page No Introduction 2 Unit Functional Schematic 2 Optical System Connection 2 Connections 2 Video Input connection 2 Optical Connections 2 Power...

Страница 2: ...f channels 8 Optical Connections OPTO OUT Connector ST Optical Launch Power 5dBm Wavelength 1310nm OPTO IN Connector ST Optical Sensitivity 22dBm Wavelength 1310nm 2684 2600 optics TX 1310nm Incoming...

Страница 3: ...SW2 is used to select between RS422 and RS485 NOTE The unit is shipped from the factory as RS485 unless otherwise requested Connections RS422 4 wire See schematic Connections RS485 2 wire See schemat...

Страница 4: ...ent no TX selected on this channel Off no video present on video CH1 input BNC Video Present CH2 Green video signal present on video CH2 input BNC Red Green Channel present no video Red Fibre Loop Pre...

Страница 5: ...te in two modes that are set by SW2 on the main PCB See below for removal of the PCB and access to SW2 Mode 1 RS485 two wire half duplex transmission Mode 2 RS422 four wire full duplex transmission In...

Страница 6: ...OFF 2 Video channel configuration OFF 3 Video channel configuration ON 4 Primary Secondary Board Setting OFF 5 Dual Redundant Not dual redundant OFF 6 Not Used OFF 7 Not Used OFF 8 On board data Separ...

Страница 7: ...2000 However it is always advisable to follow good practice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre...