AMG5904A966G Instruction Sheet
D22136-00.doc

Introduction

Unit Functional Schematic

The

AMG5904A966G

transmits and

receives 2 data channels, 2 Echelon FTT-
10A data channels, 6 bi-directional audio
signals and 8 bi-directional alarm signals
to/from the

AMG5903A966

transmit unit.

Ethernet connectivity is also provided
between the two units.

Optical Connection

The

AMG5904A966G

connections are illustrated in the following example which shows an

AMG5903A966G

data transmit unit together with an

AMG5904A966G

rackmount data receive unit

configured as a point to point system.

Содержание AMG5904A966G

Страница 1: ...t for a Singlemode Fibre Link The AMG5904A966G is a rackmount data receive unit designed to transmit and receive 2 data channels 6 audio channels 2 Echelon FTT 10A data channels and 8 bi directional a...

Страница 2: ...4 Echelon FTT 10A Data Channel Connection 5 Ethernet Connection 5 Front Panel Indicators 6 Power LED 6 Low Speed Data LEDs 6 Audio LEDs 6 Alarm LEDs 6 Echelon FTT 10A Data LEDs 7 Ethernet Data LEDs 7...

Страница 3: ...AMG5904A966G transmits and receives 2 data channels 2 Echelon FTT 10A data channels 6 bi directional audio signals and 8 bi directional alarm signals to from the AMG5903A966 transmit unit Ethernet co...

Страница 4: ...inal Connector Partnos Phoenix 1952296 Data Interfaces RS 232 422 485 Selected by external slide switches D1 D2 RS 232 Switch Position Top RS 422 Switch Position Middle RS 485 Switch Position Bottom I...

Страница 5: ...struction Sheet D22136 00 doc Echelon FTT 10A Data Channel Connection No of Echelon FTT 10A Data Channels 2 Echelon FTT 10A BANK A Channels 7 and 8 Echelon FTT 10A BANK B None Connector 37 way D Type...

Страница 6: ...resent on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero V V present on OUT O...

Страница 7: ...al fibre Data Present OUT Green Data channel present but not transmitting R G Data channel receiving Off Data channel not present or no connection OUT corresponds to the data signals being received fr...

Страница 8: ...evel above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively It is important therefore to terminate the RS 485 bus or the RS 422 input bus using 120 if a pre bias is pre...

Страница 9: ...dently as required The 3 examples shown are RS 232 no termination RS 422 120 or RS 485 120 Alarm Channel Configuration The AMG5904A966G provides 8 bi directional contact closure inputs alarm outputs E...

Страница 10: ...M 2 6 IN ALARM 2 6 OUT 3 GND GND 4 ALARM 3 7 IN ALARM 3 7 OUT 5 ALARM 4 8 IN ALARM 4 8 OUT Audio Channel Configuration The AMG5904A966G provides six bi directional audio channels Each audio channel in...

Страница 11: ...3 Audio CH2 IN A 22 Audio CH2 OUT A B 4 Audio CH2 IN A 23 Audio CH2 OUT A B 5 Audio CH3 IN A 24 Audio CH3 OUT A B 6 Audio CH3 IN A 25 Audio CH3 OUT A B 7 Audio CH4 IN A 26 Audio CH4 OUT A B 8 Audio CH...

Страница 12: ...ractice when working with optical fibre systems This includes Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces or point them at other peopl...

Отзывы: