AMG5424R Instruction Sheet D17406-

00 

 

 

 

 

AMG5424R            

Instruction Manual  

Dual System with 2x Independent Channels each of: 

[Receive Unit with one Bi-directional Data Channel and one 

Bi-directional Alarm for a Multimode Fibre Link] 

 

 

 

 

 

 

The 

AMG5424R

 is a 

DUAL 

rackmount data receive unit which provides two independent channels, 

each designed to transmit and receive 1 bi-directional alarm and transmit and receive 1 data signal 

over one Multimode optical fibre.   

 

The 

AMG5424R 

is designed to plug into an 

AMG2009

 or 

AMG2015

 subrack, which in turn fits into a 

19" rack system. 

 

The 

AMG5424R

 is designed to operate with two 

AMG5413

 single channel or one 

AMG5423 

AMG5424R 

dual channel transmit units in a point to point configuration. The R suffix in the partno. 

indicates a rackmount configuration. 

 

 

 

Содержание AMG5424R

Страница 1: ...larm for a Multimode Fibre Link The AMG5424R is a DUAL rackmount data receive unit which provides two independent channels each designed to transmit and receive 1 bi directional alarm and transmit and...

Страница 2: ...ptical Connection 3 Connections 4 Optical Connections Multimode 4 Power Connection 4 Data and Alarm Channel Connections 4 Front Panel Indicators 5 Power Opto LED 5 Low Speed Data LEDs 5 Alarm LEDs 5 D...

Страница 3: ...rovides two independent receive channels Each channel receives 1 data and 1 bi directional alarm signal from up to two AMG5413 transmit units It also transmits 1 data signal to each AMG5413 The schema...

Страница 4: ...hich may restrict operation to a maximum fibre length of 7km although in most cases the units will operate successfully over longer fibre lengths It is advisable however for distances greater than 7km...

Страница 5: ...d logic transitions present on input IN Off logic one V present on input IN IN corresponds to the data signals being transmitted onto the optical fibre Data Present OUT RS485 or RS422 Green logic zero...

Страница 6: ...plex two wire interface defined by the corresponding mode switch inside the enclosure Every data channel as shipped from the factory is set up for RS 485 operation unless otherwise requested The data...

Страница 7: ...OUT B OUT B OUT Note A or B in brackets in the above table refers to RS 485 RS 422 data specification Alarm Channel Configuration The AMG5424R provides one bi directional alarm output contact closure...

Страница 8: ...ng screws on the rear panel and slide the PCB sufficiently out of the case to enable access to the switch To replace the PCB into the case slide the PCB gently into the case if necessary aligning the...

Отзывы: