Replacing fixture head
(drywall)
1/4-20 x1 1/2"
Pan head screw
Warning
: Before starting any work ensure
that all sources of power are turned off. All
work must meet local/national codes and be
performed by a certified electrician.
Do not
mount fixtures vertically.
Installation Instructions
Vault w/ visor
C-Scroll w/ visor
Roundel w/ visor
These installation instructions are valid with the above Ametrix styles.
2.
3.
Sheet 2 of 5
Large, INDOOR
SRR
(S
emi-
R
ecessed
, R
emote ballast
)
Visor and Non-Visor
ADY071461 REV A(ECN070344)
2.
3.
Conduit from
power source.
(by others)
Electrical
cover plate
Fixture
housing
1.
Using cut out dimensions provided on page four(4), cut
hole into dry wall and feed power wire to hole.
2.
After removing fixture head, loosen #10-32 x3/8" Pan head
screws and remove electrical cover plate.
3.
Knock out appropriate hole for conduit and attach as shown
on page three(3).
4.
Replace cover plate and secure with #10-32 x3/8" Pan head
screws and press fixture housing into hole in drywall.
1.
Prior to pushing fixture into hole in drywall, tie off fixture
housing to structure using safety wire(by others) as show on
page three(3).
2.
Gently push fixture housing into hole and tighten 1/4-20 x 1
1/2" Pan head screw from inside fixture housing to tighten
drywall bracket around drywall.
3.
Connect appropriate wires from fixture head and ensure all
wires are properly matched.
4.
Replace fixture head assembly on keyhole screws and
tighten.
Replacing brackets on fixture housing
1.
Loosely reattach brackets to both sides of fixture housing.
2.
Press brackets flush to ceiling tile and secure using #10-32
Hex nuts.
#8-32
hex nut
(x4)
Ceiling grid
bracket
#8-32
Hex nut
(4x)
Ceiling grid
bracket
Fixture
assembly
1.
If possible, remove ceiling tile from grid to facilitate fixture
installation.
2.
Using cut out dimensions provided on page four(4), cut
appropriate size opening in ceiling tile.
3.
Carefully insert fixture assembly into cut out in ceiling tile.
Securing fixture to ceiling tile
Semi-recessed fixtures shown without thermal protectors
Wiring the fixture
(drywall)