Installation
AC Input Power
36
Operating Manual for XHR Series Power Supply
AC Input Power
We warrant that the unit will perform to specification at AC input voltage range from
85 to 250 Vac. The power output derates to 900 W when the AC input voltage is
below 95 V.
AC Fail LED
The AC Fail (ACF) LED turns on when the input voltage is outside
of the range specified for the power supply. The LED turns off when the input
voltage is within the range.
AC Input Cord
We ship the power supply with an AC input cord rated for your
for the list of power cords that we ship. Use a power cord
rated for your local voltage as long as it is within the supply’s input range as stated
in “Input Conditions” on page 26. Any cord that you use requires a standard IEC 320
termination to mate with the power supply’s AC input connector. If you need a
specific cord, call us.
Table 2.2
Power Cords
WARNING
There is a potential shock hazard if the power supply chassis and cover are not
connected to an electrical ground via the safety ground in the AC input
connector. Ensure that the power supply is connected to a grounded AC outlet
with the recommended AC input connector configured for the available line
voltage
!
CAUTION
When the power switch is turned on, the output voltage or current previously set
will be applied to loads
Location
Power Cord Rating
North America
125 V, 13 A NA plug
Asia
125 V, 13 A NA plug
Great Britain
250 V, 10 A British plug
Содержание Sorensen XHR 100-10
Страница 2: ......
Страница 4: ...This page intentionally left blank ii ...
Страница 6: ...This page intentionally left blank iv ...
Страница 8: ...This page intentionally left blank vi ...
Страница 12: ...List of Figures x Operating Manual for XHR Series Power Supply ...
Страница 14: ...List of Tables xii Operating Manual for XHR Series Power Supply ...
Страница 47: ...Installation Load Connection 47 Figure 2 9 Multiple Loads with Remote Sensing ...