Specifications
A-2
TM-F2OP-C1XN-01
Electrical Specifications
These specifications are warranted over a temperature range of 0 °C to
50 °C.
Nominal ambient temperature assumed is 25 °C.
Nominal line voltage is 208 Vac, 60 Hz.
See Table A-1 and Table A-2 for maximum values for model-dependent
specifications.
Specifications are subject to change without notice.
Table A-1
Specifications for 7.5 V to 40 V Models
Models
7.5-300
12-220
20-130
33-85
40-70
Output Ratings:
Output Voltage
a
Output Current
b
Output Power
0-7.5 V
0-300 A
2250 W
0-12 V
0-220 A
2640 W
0-20 V
0-130 A
2600 W
0-33 V
0-85 A
2805 W
0-40 V
0-70 A
2800 W
Line Regulation:
c
Voltage
(0.01% of Vmax +
2 mV)
Current (0.01% of Imax + 2 mA)
2.75 mV
32 mA
3.2 mV
24 mA
4 mV
15 mA
5.3 mV
10.5 mA
6 mV
9 mA
Load Regulation:
d
Voltage (0.02% of Vmax +
5 mV)
Current (0.02% of Imax + 5 mA)
6.5 mV
65 mA
7.4 mV
49 mA
9 mV
31 mA
11.6 mV
22 mA
13 mV
19 mA
Meter Accuracy:
Voltage (1% of Vmax + 1 count)
Current (1% of Imax + 1 count)
0.09 V
4 A
0.13 V
2.3 A
0.3 V
1.4 A
0.43 V
0.95 A
0.5 V
0.8 A
Output Noise (0-20 MHz):
Voltage (p-p)
100 mV
100 mV
100 mV
100 mV
150 mV
Output Ripple (rms):
Voltage
Current
e
10 mV
1600 mA
10 mV
1200 mA
10 mV
400 mA
15 mV
300 mA
15 mV
200 mA
Drift (30 minutes):
f
Voltage (0.07% of Vmax)
Current (0.7% of Imax)
For Resistive Programming:
Voltage (0.6% of Vmax)
Current (0.6% of Imax)
3.75 mV
2100 mA
45 mV
1800 mA
6 mV
1540 mA
72 mV
1320 mA
10 mV
910 mA
120 mV
780 mA
16.5 mV
595 mA
198 mV
510 mA
20 mV
490 mA
240 mV
420 mA
Содержание Sorensen XFR 100-28
Страница 3: ...This page intentionally left blank ii...
Страница 5: ...This page intentionally left blank iv...
Страница 7: ...This page intentionally left blank vi...
Страница 13: ...xii...
Страница 15: ...xiv...
Страница 25: ...1 10...
Страница 67: ...3 18...
Страница 73: ...Remote Operation 4 6 TM F2OP C1XN 01 Figure 4 1 Connecting Programming Sources to J2 Connector...
Страница 75: ...4 8...
Страница 87: ...5 12...