Asterion DC Multioutput Series
Programming Manual
M330517-01 Rev C
6-23
Ethernet/LAN Configuration
•
Ethernet Standard: IEEE-802.3 compliant
•
Technology: 10/100Base-T
•
Protocol: TCP/IP, IPV4
•
ICMP (ping server): Always Enabled
•
mDNS/DNS-SD: Always Enabled
•
IP Address Assignment: Via DHCP or Static IP
•
VXI-11 Discovery: Supported
6.3.1
Ethernet Configuration Factory Defaults
PARAMETER
DEFAULT
Host Name
AST<base model>-<last four digits of serial number>
Description
AST Power Supply <base model>
IP Address
* DHCP-acquired, If DHCP server absent, assigned via
Auto-IP
Subnet Mask
* DHCP-acquired, If DHCP server absent, assigned via
Auto-IP
Gateway
* DHCP-acquired, If DHCP server absent, assigned via
Auto-IP
DNS Server
0.0.0.0
Listening Port
52000
User ID
Admin
Password
Password
*
The Ethernet interface provides the opportunity to assign an IP address via Auto-IP.
If DHCP server fails to assign an IP address and Auto-IP setting is ON, the unit gets
an IP address in the range of 169.254.X.X.
Ethernet Setup Procedure
There are three ways to setup the Ethernet network in the Asterion DC Multioutput series
power supply.
•
Network setup using DHCP Server
•
Network Setup using Auto-IP (Direct Connection between Asterion power
supply and PC using Cross cable)
•
Network Setup using Static IP
The network setups are described in the subsections that follow. Use the Setup procedure
that applies to your system and application to configure the Ethernet.
NOTE:
When connecting your Asterion DC Multioutput Series power supply to a network,
it is strongly recommended to use Linksys® hubs or switches, which have undergone
Содержание Sorensen Asterion DC ASM
Страница 1: ...M330517 01 Rev C Asterion DC Multioutput Series Programming Manual...
Страница 6: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C v SAFETY SYMBOLS...
Страница 17: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C xvi This page intentionally left blank...
Страница 20: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 1 3 This page intentionally left blank...
Страница 24: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 2 7 This page intentionally left blank...
Страница 26: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 3 9 This page intentionally left blank...
Страница 33: ...Asterion DC Multioutput Series Programming Manual 4 16 M330517 01 Rev C This page intentionally left blank...
Страница 38: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 5 21 This page intentionally left blank...
Страница 52: ...Asterion DC Multioutput Series Programming Manual M330517 01 Rev C 6 35 This page intentionally left blank...
Страница 55: ...Asterion DC Multioutput Series Programming Manual 7 38 M330517 01 Rev C This page intentionally left blank...
Страница 63: ...Asterion DC Multioutput Series Programming Manual 8 46 M330517 01 Rev C This page intentionally left blank...
Страница 73: ...Asterion DC Multioutput Series Programming Manual 9 56 M330517 01 Rev C This page intentionally left blank...
Страница 115: ...Asterion DC Multioutput Series Programming Manual 10 98 M330517 01 Rev C This page intentionally left blank...
Страница 119: ...Asterion DC Multioutput Series Programming Manual 11 102 M330517 01 Rev C This page intentionally left blank...
Страница 137: ...Asterion DC Multioutput Series Programming Manual 12 120 M330517 01 Rev C This page intentionally left blank...
Страница 145: ...Asterion DC Multioutput Series Programming Manual 13 128 M330517 01 Rev C CAL n LOCK...
Страница 159: ...Asterion DC Multioutput Series Programming Manual 13 142 M330517 01 Rev C This page intentionally left blank...
Страница 162: ...M330461 01 Rev C 14 145...