Страница 1: ......

Страница 2: ...Gaiter Clearance 4 4 2 Tip 5 4 3 Pneumatic Probe 5 5 0 Handling Maintenance 7 6 0 W Series Application Notes 8 7 0 Linear Encoder Operation 9 8 0 Orbit3 and Orbit ACS Digital Probe with Connector Oper...

Страница 3: ...n is to be found WARNINGS Do not operate in an explosive atmosphere To avoid explosion do not operate this equipment in an explosive atmosphere Air Supply On LE 12 P and LE 25 P under no circumstances...

Страница 4: ...Products to form a fully comprehensive Orbit Measurement System See Orbit 3 System Manual Orbit ACS Modules feature a local display which shows probe readings and allow the configuration of the ACS m...

Страница 5: ...motion degrades then back off screw until motion returns to smooth ensure probe is secure Method 1 Typical Clamping Torque M4 Screw 0 30 0 35 Nm M5 Screw 0 35 0 40 Nm Method 2 Clamping Torque dependan...

Страница 6: ...apply without connection to air Air pressure may be varied within the specified limits see catalogue to achieve the desired tip force Pneumatic Probes Type DP x P and LE x P are designed to be leak f...

Страница 7: ...will remain operational with a damaged gaiter but the integrity of the probe will be compromised Feather Touch Pneumatic Probes Type DT x P are designed to leak a small amount of air around the shaft...

Страница 8: ...4 Install new tip while holding locking tool 5 Hand tighten tip 6 Slide down gaiter IP65 and pneumatic versions only Gaiter Locking Tool Tip 5 0 Handling Maintenance DT 30 P Bearing Maintenance The D...

Страница 9: ...operation 1 Air supply must be clean and dry ie Max 60 RH and filtered to particle size of 0 1 mm 2 The operating environment must be clean and dry Viscous materials contaminating the probe shaft can...

Страница 10: ...probe body after removal of blanking screw Pneumatic Operation A Pneumatic nozzle is fitted as standard to LE 12 P LE 25 P By applying air between 0 5 0 8 bar the measuring tip will extend to meet co...

Страница 11: ...ed when communicating via Orbit For example when notifying a DP with connector the module Orbit Identity is returned When connecting a different compatible probe to a module re mastering re zeroing is...

Страница 12: ...bit ACS Range Error is displayed for already set up modules It is not possible to notify set up a module with an incompatible probe error condition Reconnecting a compatible probe and powering the sys...

Страница 13: ...and con tamination For probes without gaiters then the working environment must be clean and dry It is the user s responsibility to ensure that the application is suitable for the probe type selected...