Ametek PST-2000 Скачать руководство пользователя страница 7

7 General Test Procedure

Use the following table to find the section for the gauge you wish to test.

If, after testing according to the appropriate procedure, the gauge does not function as

described, replace it. If the gauge is functioning properly and is accurate, refer to the ap-

propriate AMETEK Dixson Product Information Note (PIN) for troubleshooting tips.

To test this gauge,

See Section:

PIN:

Gauge Identification

900 Series Speedometer

8

072-40283

Blue plastic housing, or

mounted in 6/7 instrument

cluster.

900 Series Tachometer

9

072-40284

Blue plastic housing, or
mounted in 6/7 instrument

cluster.

Fuel and Temperature
Gauges

10

072-40289

2-inch metal housing, or
mounted in 6/7 instrument
cluster.

Ammeter

11

072-40288

2-inch metal housing.

Notes -

You can obtain the Accuracy Tables and Product Information Notes

referred to in this document by calling our Product Support Depart-

ment or by downloading them from our website at

www.ametekdixson.com.

The PST-2000 cannot test voltmeter gauges. See AMETEK Dixson

Product Information Note 072-40287 for information about trouble-

shooting voltmeter gauges.

Important!

The PST-2000 cannot calibrate gauges. Do not set the tool to a par-
ticular frequency or resistance value and then check the pointer
position. Instead, use the tool to position the pointer as directed in
the procedure, note the value indicated on the tool and verify it
falls within the given frequency range listed in the Accuracy Table
referenced by that procedure.

When using the tool to position the pointer to full scale, the fre-
quency displayed on the tool corresponds to the values given in
the Accuracy Tables called out in these procedures and not with
other calibration charts and booklets.

Using the PST-2000 with Freightliner Trucks

072-40236-B

Page 5 of 10

Содержание PST-2000

Страница 1: ...Using the PST 2000 with Freightliner Trucks Document Number 072 40236 B...

Страница 2: ...nd specifications without notice Free telephone assistance is available Monday through Thursday between 7 a m and 5 30 p m Mountain Time and Friday between 7 00 a m and noon AMETEK Dixson Product Supp...

Страница 3: ...vironment It will operate between 14 and 122 degrees Fahren heit and is spill resistant Use only a soft cloth and a mild non abrasive soap to clean the PST 2000 Do not use gas oline alcohol or solvent...

Страница 4: ...only 243 12833 Carrying Case 243 14028 Standard Input Cable 900 6 7 Panel Speedo Tach 180 12840 Input Cable Cigarette Lighter Socket Adapter 180 12848 Input Cable External Power Supply 180 12847 Optio...

Страница 5: ...eir power from a cigarette lighter socket an external power source or an AC DC adapter The output cables plug into the gauges to be tested The tool lets you vary the frequency of pulses sent to the sp...

Страница 6: ...d input cable that provides power to the tool and two standard output cables that send signals to the gauges Optional input and output cables are available The cables are connected as shown in Figure...

Страница 7: ...oduct Information Notes referred to in this document by calling our Product Support Depart ment or by downloading them from our website at www ametekdixson com The PST 2000 cannot test voltmeter gauge...

Страница 8: ...s switch combination in the Switches Closed column of Accuracy Table 072 40319 7 Check the speedometer s accuracy at 50 mph as follows a Read across the row that contains your speedometer s switch com...

Страница 9: ...of the red LEDs is on the Input Voltage switch may not be set to the vehicle s battery voltage or the battery voltage is too high or too low c If no LED is on the PST 2000 fuse may be blown the PST 2...

Страница 10: ...the 880 10k range and adjust the Signal Adjust knob to position the pointer at 3000 rpm If the tachometer is accurate at full scale the PST 2000 will display between 8232 and 8568 as given in the Full...

Страница 11: ...owing on the Resistance Out switches will be between 103 and 119 ohms as shown in Table 2 11 Ammeter 1 Unplug the gauge to be tested and connect the PST 2000 as described in Figure 2 2 Turn the PST 20...

Страница 12: ...hen no gauge is connected to the tester Disregard this indication 4 When you press and release the Ammeter 1 button the ammeter s pointer should go momentarily to full scale 60 100 or 120 amperes depe...

Отзывы: