AMETEK CTS
H-Field Test
Operating Manual
V 1.20
32 / 37
3.
Technical data
Magnetic field antenna
MFC 1000
,
1 m x 1 m
MFC 1000.1
,
1 m x 1 m
Number of turns
1, (single turn)
1, (single turn)
Antenna factor
0,87/m
0,87/m
Nominal current
8/20
s pulse current up to 2.000 A 8/20
s pulse current up to 2.000 A
50/60 Hz AC current
50/60 Hz AC current
continuous 250 A/m
continuous 250 A/m
short time for 3 s 1.200 A
short time for 3 s 1.200 A
Connectors
Safety laboratory plugs 4mm
M14 screws
continuous ac currents up to 32A/ plug
3.2kA (8/20
s pulse current)
High current plugs
continuous ac current > 30A to 250A
cont. ac current > 30A to 250A
short time currents 3 s up to 1500A
short time currents 3s up to 1500A
Construction
Double stand for MFC 1000 coil with base Height adjustable and coil 360
on casters with brakes; rotation mechanism degrees rotatable; double stand
with 3 position brakes.
turntable for horizontal and vertical fields turntable for horizontal and
vertical fields
Material
Aluminium, 4cm² cross section
Aluminium, 4cm² cross section
Weight
15,5 kg
15.5 kg
50/60Hz magnetic field
Variac
variac NX1-260-16, 0-260 V/16 A
variac NX1-280-16, 0-280 V/16 A
VAR 3005A-S16, 0-260 V/16 A
Manual variac 0-260 V, 5 A ( for magnetic fields up to 100 A)
Line voltage variac NX1-2x0-16
230V 16A
(for H-field 1.000 A/m: max. 39A for 3s)
Current transformer (30 A/m)
Type
MFT 30
Input voltage
0
– 250 V rms
Output current
0
– 50 A rms
Weight
5,50 kg Transformer
0,35 kg 4 Safety labor cables 2m
Dimension
260 x 180 x 100 mm³
Current transformer (1.000 A/m)
Type
MFT 100
Input voltage
0
– 250 V rms
Output current
(Transformator)
0
– 250 A rms continuous transformator secondary
max. 1.200 A for 3 s (approx. 600 A for 115 V line power)
200 A rms continuous (cable connection MFT 100
– MFC 1000.x with 50mm²)
Connector
male:
Multicontact KST 14AR-N/50
200 A cont, 3 kA 3s
female: Multicontact KBT 14AR-N/50
200 A cont, 3 kA 3s
Weight
26,45 kg Transformer
2,0 kg Cable 2 units
0,25 kg Mains cable
Dimension
260 x 380 x 200 mm³
Waveform
Sinewave
Pulsed magnetic field
using a compact NX5/NX7, NSG 30x0A
Mode
Single pulse, max. repetition rate 10 s
Current range
100...2.000 A (multiplied with antenna factor)
Current wave shape
8/20
s current pulse as per IEC 1000-4-5
Polarity
Positive and negative
Synchronization
0 - 360° in steps of 10°