12. 

Drift Window

:  Establish an acceptable drift window.  If the slide moves outside of 

this window, the In Position relay denergizes.  Typically 0.010 to 0.020 inch.

F     -     1     -     8     -     ENT     -     Value     -     ENT

Note

:  In any cases where F - 3 - 9 - 1 - ENT is used, steps one (1) through eleven (11) will be erased from memory and 

will have to be repeated.

The calibration steps are now completed and the system is ready for programming.

Chapter 3:  Programming and Operating Instructions

Programming Dies:

1.  

Programming New Die #’s and Shut Height Values

:

A.  Select “Prog” mode on keyswitch

B.  Depress F - 1 - ENT

C.  Depress DIE # - Die code # - ENT

D.  Enter shut height and depress ENT

E.  *Optional Counter Balance Entry

*Optional Counter Balance Entry

     Enter counter balance value (1-16) and depress ENT

The counter balance value will generate a (4) four binary output from the rear of the Ram-Set proportional to the pro-

grammed value.  The binary output will interface to Gemco Series 2200 to automatically adjust the press counter balance.

Note

:  It is important that shut height value entered has been pre-tested with die in press prior to entry.

To program new die #’s and shut heights at this point, simply start at step C.

2.  

Operating in Auto Mode

:  This function allows the retrieval of existing programmed

dies and their associated shut heights.

A.  Keyswitch in auto mode.

B.  Depress DIE # - Die code # - ENT.  The programmed optional counter balance will 

now appear on the display for 3 seconds then it will display the shut height value.

C.  Verify that shut height value and counter balance value correspond to the selected 

die.

D.  Depress ENT.  This will enable the drive sequence.  The drive sequence will remain 

active until the shut height drive mechanism moves the slide to the programmed value.

E.  Select “Standby” mode on keyswitch.  The auto adjust sequence is now complete.

3.  

Operating in Jog Mode

:  This function allows the customer to manually jog the slide 

using the Ram-Set keys.

A.  Keyswitch in job mode.

B.  Depress appropriate “Jog up” or “Jog down” key on unit for appropriate motion.

Содержание Gemco 1996 Ram-Set

Страница 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Страница 2: ...Gemco 1996 Ram Set Automatic Press Shut Height Controller Installation and Maintenance Manual Gemco 1996 Ram Set Automatic Press Shut Height Controller...

Страница 3: ...com www ametek com Copyright 2001 by AMETEK Automation Process Technologies All Rights Reserved Made in the USA Version 1 0 Preface This manual provides a system description installation maintenance...

Страница 4: ...Electrical Installation Chapter 3 Programming and Operating Instructions 3 1 RS 485 Protocol Information Chapter 4 Maintenance and Trouble Shooting Chapter 5 Programming and Function Charts Chapter 6...

Страница 5: ...cessor to carry out all programmed directions The following features are found on the Ram Set faceplate Display A six 6 digit L E D read out will show current shut height position programming details...

Страница 6: ...ion Relay This relay will energize when the customer programmed shut height is achieved The controller allows programming of a value at which the in position relay will stay energized The output of th...

Страница 7: ...uld be slotted as shown in the transducer installation drawing The transducer bracket should be mounted to a fixed member of the slide and the magnet assembly bracket to a movable portion of the slide...

Страница 8: ...ion Introduction The Ram Set is designed for use in an industrial environment and incorporates extensive transient suppression circuitry How ever the same general installation rules should be followed...

Страница 9: ...is selected all programmable values are entered as millimeters except the wire speed The wire speed is still entered in inches per microsecond i e the wire speed printed on the transducer s can This...

Страница 10: ...t setting F 1 3 Value ENT 10 Slow Dwell The slow dwell settings are the method the Ram Set uses to precisely position the slide These time based dwells on off are attached to the up down output relays...

Страница 11: ...ue The binary output will interface to Gemco Series 2200 to automatically adjust the press counter balance Note It is important that shut height value entered has been pre tested with die in press pri...

Страница 12: ...d depress F 1 8 ENT WINDOW VALUE ENT When in the AUTO mode the Ram will move to the center of the window before stopping 8 Jogging with System Errors Should the transducer and or cable become disabled...

Страница 13: ...32 systems including the host computer can be tied into this link System Protocol The Ram Set is factory set for 9600 baud rate 8 bit word length 1 stop bit parity off and parity even To change baud...

Страница 14: ...est a transducer position 3A Precedes returned function data 3D Requested data is unavailable After the Ram Set has successfully received a message it will transmit the following A If no data was requ...

Страница 15: ...loss of 110 V A C on slide gap interference input EE0000 All are correct Note If more than one error exists a combined error message will be displayed Ex a slide gap interference fault and lower limit...

Страница 16: ...Installation and Maintenance Manual...

Страница 17: ...k voltage across GND and run terminals on output board See A for cause of errors C To check in position contact put keyswitch in stand by mode Depress the die key which will display last used die numb...

Страница 18: ...Transducer calibration wire speed 9 040 in sec 1 000 to 65 000 in sec 10 Up down counting direction 0 Up 0 Up 1 Down 11 Slow down entry point 0 050 inch 0 to 259 inch 12 Upper limit 48 999 inch 0 to...

Страница 19: ...1080 North Crooks Road Clawson MI 48017 800 635 0289 248 435 0700 248 435 8120 www ametekapt com www ametek com 1996 M1R 03 02 Z150 5C...

Страница 20: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Отзывы: