Ametek Drexelbrook IntelliPoint RF RNL Series Скачать руководство пользователя страница 87

May 2018 

WHETHER ORAL, WRITTEN, EXPRESS, IMPLIED OR STATUTORY.  

NO IMPLIED OR STATUTORY WARRANTIES OF 

MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE 

SHALL APPLY.  

VII. PATENTS/INDEMNITY 

If Buyer receives a claim that 

Products, or part thereof manufactured by Seller infringes a patent, 

Buyer shall notify Seller promptly in writing and give Seller information, 

assistance and exclusive authority to evaluate, defend and settle such 

claim.  Where Buyer has furnished specifications/designs for the 

manufacture of the allegedly- infringing Products, Buyer shall defend, 

indemnify and hold harmless Seller against third-party claims for 

infringement arising out of Seller’s use of such specifications/designs. 

VIII. 

LIMITATION OF LIABILITY 

The total liability of Seller on any claim, whether in contract, tort 

(including negligence of any degree and strict liability) or otherwise 

arising out of, connected with, or resulting from the manufacture, sale, 

delivery, resale, repair, replacement or use of any Products/Services, 

shall not exceed the price allocable to the Products/Services or part 

thereof which gives rise to the claim. 

IN NO EVENT, WHETHER AS A 

RESULT OF BREACH OF CONTRACT, WARRANTY, TORT, 

(INCLUDING NEGLIGENCE OF ANY DEGREE, STRICT LIABILITY OR 

PATENT INFRINGEMENT) OR OTHERWISE, SHALL SELLER, ITS 

AFFILIATES, SUBCONTRACTORS, OR SUPPLIERS BE LIABLE FOR 

ANY LOSS OF PROFIT OR REVENUES, LOSS OF USE OF THE 

PRODUCTS OR SERVICES, OR ANY ASSOCIATED EQUIPMENT, 

COST OF CAPITAL, COST OF SUBSTITUTE GOODS, FACILITIES, 

SERVICES OR REPLACEMENT POWER, DOWNTIME COSTS OR 

CLAIMS OF BUYER'S CUSTOMERS FOR DAMAGES OR FOR ANY 

SPECIAL, PROXIMATE, CONSEQUENTIAL, INCIDENTAL, INDIRECT 

OR EXEMPLARY DAMAGES.

 If Buyer transfers title to, or leases 

Products sold hereunder to, or otherwise permits or suffers use by, any 

third party, Buyer shall obtain from such third party a provision affording 

Seller and its subcontractors/suppliers the protection of the preceding 

sentence.  Any action against Seller must be brought within 18 months 

after cause of action accrues. 

IX. 

EXCUSABLE DELAYS  

A.  Seller shall not be liable for delays 

in delivery or failure to perform due directly or indirectly to causes 

beyond Seller's reasonable control including but not limited to: acts of 

God; war; terrorism; civil commotion; riots; embargoes; government 

regulations, orders, instructions or priorities; port congestion; acts of or 

failure to act on the part of Buyer or its agents/employees; fires; floods; 

sabotage; nuclear incidents; earthquakes; storms; epidemics; strikes; 

lockouts or other labor difficulties; shortages of or inability to timely 

obtain proper labor, materials, components, shipping space or 

transportation, fuel, supplies or power at current prices;  or due to 

limitations imposed by the extent of availability of Seller’s normal 

manufacturing facilities.  

B.  If a delay excused per the above extends for more than 90 days and 

the parties have not agreed upon a revised basis for continuing providing 

Products/Services at the end of the delay, including adjustment of the 

price, then either party (except where delay is caused by Buyer, in which 

event only Seller) upon thirty (30) days’ notice may terminate the Order 

with respect to the unexecuted portion of the Products/Services, 

whereupon Buyer shall promptly pay Seller its reasonable termination 

charges upon submission of Seller's invoices thereof.  

X. 

SOFTWARE/TECHNICAL/PROPRIETARY INFORMATION  

A.  Buyer shall not acquire any rights to any software which may be 

delivered with Products, except as granted in Seller’s standard software 

license.  Any software license granted in connection with Products shall be 

an interim license, which may be withdrawn, pending payment for Products 

in full.   

B.  The purchase of Products shall not include any right to supply of 

technical information such as drawings or specifications.   

C.  Proprietary information, including drawings, documents, technical data, 

reports, software, designs, inventions and other technical information 

supplied by Seller in connection herewith (hereinafter called "Data"), shall 

remain Seller's sole property and shall be held in confidence by Buyer.  

Data shall not be reproduced, used or disclosed to others by Buyer without 

Seller’s prior written consent.  Upon completion of Order, Buyer shall 

promptly return all Data to Seller together with all copies or reprints thereof 

then in Buyer's possession or control, and Buyer shall thereafter make no 

future use, either directly or indirectly, of any Data or any information 

derived therefrom without Seller's prior written consent. The foregoing shall 

in no way obligate Seller to provide or supply Data. 

XI. 

DIES, TOOLS, PATTERNS  

Seller’s charges for dies, molds, 

patterns and the like represent the Buyer’s proportionate cost thereof, it 

being expressly understood that they remain the property of Seller.  

Modifications made to dies, molds, patterns and the like in order to 

manufacture Products shall be at the discretion of Seller. 

XII. 

GENERAL  

A.  

The rights and obligations of the Buyer and 

Seller hereunder shall be governed in all respects by the law of the 

Commonwealth of Pennsylvania, U.S.A.  The exclusive forum for 

adjudication of any disputes shall be the federal or state courts of the 

Commonwealth of Pennsylvania, and Buyer/Seller hereby consent to 

personal jurisdiction and venue in such courts in any proceeding. The 

United Nations Convention on the International Sale of Goods shall not 

apply. 

B. These Terms and Conditions of Sale together with any other terms 

specifically agreed to in writing by Seller constitute the entire agreement 

between Buyer and Seller and supersede any prior or contemporaneous 

representations, agreements, proposals, warranties, or understandings, 

oral or written, express or implied.  No waiver, modification, amendment, 

rescission or other change to these Terms and Conditions of Sale shall 

be binding unless specifically agreed to in writing by an authorized 

representative of Seller. 

C.  The invalidity, of any part hereof shall not affect the validity of the 

remainder. The failure of Seller to assert any right at any time hereunder 

shall not prevent Seller's subsequent assertion of the same or different 

rights. 

D.  Buyer may not assign this contract without the prior written approval 

of the Seller. 

XIII. 

PROHIBITION FOR HAZARDOUS USE 

Products sold hereunder are not intended for application in, and shall not 

be used by Buyer in construction or application of a nuclear installation 

or in connection with use or handling of nuclear material or for any 

hazardous activity or critical application, where failure of a single 

component could cause substantial harm to persons or property, unless 

Products have been specifically approved for such activity or application.  

Seller disclaims all liability for loss or damage resulting from such 

unauthorized use and Buyer shall defend, hold harmless and indemnify 

Seller against any such liability, whether arising under breach of 

contract, warranty, tort (regardless of the degree of fault or negligence), 

strict liability or otherwise. 

Where Seller approves the application of the Products in a nuclear 

facility, the Buyer shall, before such use or provision, arrange for 

insurance or governmental indemnity protecting the Seller against 

liability and hereby releases and agrees to indemnify the Seller and its 

suppliers for any nuclear damage, including loss of use, in any manner 

arising out of a nuclear incident, whether alleged to be due, in whole or 

in part to the negligence or otherwise of the Seller or its suppliers.

XIV. 

STATUTORY REQUIREMENTS 

Seller reserves the right to make any changes in the general 

specifications of the Products which are required for the Products to 

conform to any statutory requirement. 

XV. 

GOVERNMENT CONTRACTS 

Only Federal Acquisition Regulation (“FAR”) supplement clauses 

expressly accepted in writing by Seller shall be included or incorporated 

by reference herein.  Seller shall not be bound by and makes no 

representation of compliance with any FAR or FAR supplement clauses 

that Seller shall not have expressly accepted in writing. 

Содержание Drexelbrook IntelliPoint RF RNL Series

Страница 1: ...eries Point Level Switch NOTICE The AutoVerify feature in The IntelliPoint switch is shipped DISABLED For critical High Level applications we recommend enabling the AutoVerify feature Telephone 1 215...

Страница 2: ...ained in this manual including but not limited to implied warranties or fitness for a particular purpose Drexelbrook shall not be liable for errors contained herein or for incidental or consequential...

Страница 3: ...ad Horsham PA 19044 Telephone 1 215 674 1234 Fax 1 215 674 2731 E mail drexelbrook sales ametek com Website www drexelbrook com An ISO 9001 Certified Company IntelliPoint RF Series Point Level Switch...

Страница 4: ...Contents...

Страница 5: ...4 3 Over Range 23 4 4 Under Range 23 4 5 Testing The Relay Circuits 23 4 6 Testing The Sensing Element 24 4 7 Testing the Integral Cable 27 4 8 Testing the Remote Cable 27 4 9 Testing the Power Suppl...

Страница 6: ...Section 1...

Страница 7: ...al is demodulated rectified amplified and the output is increased There are drawbacks however especially when there is coating of the probe An RF Admittance level transmitter is the next generation Al...

Страница 8: ...m 16 bar RF 316 316L SS ET1 80 mm 40 bar RF 316 316L SS EU1 100 mm 16 bar RF 316 316L SS EV1 100 mm 40 bar RF 316 316L SS EW1 150 mm 16 bar RF 316 316L SS EX1 150 mm 40 bar RF 316 316L SS E02 25 mm 16...

Страница 9: ...nsor 305mm 2 12 inches2 w Curved radius 153 229 305mm 6 9 or 12 700 0207 003 Remote 0 1 bar 82 C 1 PSI 180 F 304SS and Neoprene 53 Flush Mount Sensor 305mm 2 12 inches 2 Extra Heavy Duty 700 0207 004...

Страница 10: ...Input Output Module External Tag Loop 2 External Lid Lock 2 M4 2 5 mm Hex Drive Conduit Entries 2 inch NPT FM FMc Systems M20 x 1 5 ATEX IECEx Systems LABEL see below Equipotential Connection The Inp...

Страница 11: ...y 385 48 18 Circuit Board RLL 2pf Fixed Calibration 385 48 003 FL2 RHL Auto Calibration 0 5pf 385 48 19 HL1 RNL Auto Calibration 2pf 385 48 19 003 NL1 RPL 0 5pf Fixed Calibration 385 48 19 PL2 RTL Aut...

Страница 12: ...Section 2...

Страница 13: ...uld be between limits as specified by control drawings in section 6 The IntelliPoint RF instrument utilizes a dual compartment housing and a completely encapsulated input output module to reduce possi...

Страница 14: ...Refer to Figure 2 2 When installing the IntelliPoint RF instrument ambient temperature at the electronics must not exceed 70 C 158 F When installing flange mounted sensing elements keep mating surfac...

Страница 15: ...ree screws See Figure 2 3 WARNING If the IntelliPoint instrument is located in a hazardous environment do not open the enclosure cover or make break any electrical connections without first disconnect...

Страница 16: ...Slotted Drive Ground Connection 8 32 Phillips Slotted Drive M4 2 5mm Hex Drive 2 3 1 5 6 4 7 8 L2 NO L1 NC NO C C NC 85 to 250 VAC 21 to 100 VDC Auto Detecting Relay 1 Relay 2 2 5 Spark Protection App...

Страница 17: ...ESS FOR POST TP1 Figure 2 4 Circuit Board shown in detail Do NOT push the Recal button without first ensuring that the material being measured is below the sensing element SENSING ELEMENT CIRCUITS VIE...

Страница 18: ...er N O contacts open and N C contacts closed Low Level Failsafe LLFS is the alarmed condition when probe is uncovered Relay will de energize when level is low indicating low level upon loss of power N...

Страница 19: ...al High Level applications we recommend enabling the AutoVerify feature AutoVerify is a self test function that continuously checks the system for proper operation when the unit is in the High Level F...

Страница 20: ...4 7 8 NO NC NO C C NC 3 5 6 4 7 8 NO NC NO C C NC 3 5 6 4 7 8 NO NC NO C C NC 3 5 6 4 7 8 NO NC NO C C NC Tank Condition Relay 2 Alarm AutoVerify disabled Relay 2 Fault AutoVerify disabled LED On LED...

Страница 21: ...iPoint RF instruments that are mounted remotely from the sensing element an additional housing with terminals is provided to connect the cable from the sensing element This housing is factory wired to...

Страница 22: ...Sensing Element Connection continued Figure 2 7 Sensing Element Connection Remote Housing Housing and Bracket are shown rotated 90 for clarity GSC G Ground S Shield C Center NOTE CLIPPED SHIELD W MUS...

Страница 23: ...Calibration IntelliPoint and have determined you require a Manual Calibration IntelliPoint based on the Application Guide please contact the AMETEK Drexelbrook Service Department 3 1 2 Using The Intel...

Страница 24: ...system while the LED s are flashing and reset will occur immediately The system is now ready for installation Nonvolatile Memory The IntelliPoint has nonvolatile memory which allows the unit to re st...

Страница 25: ...This mode provides a 2 pF preload alarm setpoint is locked to starting capacitance value recorded at system start up Mode 3 Auto Cal 10 pF This mode provides a 10 pF preload alarm setpoint varies dep...

Страница 26: ...hunt jumper from the Time Delay Selection Jumper and place it on pins 1 2 of JP5 The green LED will go out and the red LED s will begin to flash The number of flashes indicates which mode the unit is...

Страница 27: ...een unit and sensor is damaged Check connection cable for shorts opens or damage and proper termination Section 4 6 4 7 Switch delays in responding to material Reverse acting time delay may be active...

Страница 28: ...g Integral Cable or Section 4 8 Testing Remote Cable 5 If the IntelliPoint is stuck in one state A Remove power B Disconnect coax cable that joins sensing element to electronic unit C Apply power D Re...

Страница 29: ...elay circuits A Relay circuits consist of a single pole double throw relay contacts brought out to terminal strips for external switching See Figure 4 1 B Relay operation may generally be heard as an...

Страница 30: ...t the sensing element has passed the test If lower resistance was measured continue with testing 3 Clean sensing element and repeat resistance measurements with the sensing element external to the ves...

Страница 31: ...FailSafe Tank Full 3 5 6 4 7 8 NO NC NO C C NC Low Level FailSafe Tank Full 3 5 6 4 7 8 NO NC NO C C NC Low Level FailSafe Tank Empty 3 5 6 4 7 8 NO NC NO C C NC 3 5 6 4 7 8 NO NC NO C C NC 3 5 6 4 7...

Страница 32: ...GROUNDED TO HOUSING TO OUTER CONDUCTOR Red Lug PACKING GLAND DO NOT DISTURB PROBE MEASUREMENT SHIELD MEASUREMENT Sensing Element in Vessel Center Conductor to Housing ___________________ Ohms Center...

Страница 33: ...ck for shorts a The integral cable is tested as part of sensing element test section 4 6 1 Disconnect remote cable from electronic unit and sensing element 2 Using an ohmmeter measure the resistances...

Страница 34: ...tion See to Section 2 8 Sensing Element Connection 4 Reapply power 5 Using a DC voltmeter measure voltage from 5 to Common and 5 to Common Correct readings are 5 to 6 and 5 to 6 Vdc See Figure 4 6 4 8...

Страница 35: ...ief description of the problem_________________________ ______________________________________________________ ______________________________________________________ Checkout procedures that have fail...

Страница 36: ...he following information Model Number of Return Equipment_____________________ Serial Number__________________________________________ Original Purchase Order Number________________________ Process ma...

Страница 37: ...Troubleshooting 31 Section 5...

Страница 38: ...Storage Temperature 40 to 85 C 40 to 185 F Indicators LEDs Green Power Red Relay 1 Red Relay 2 Self Check Continuous AutoVerify and Manual Certify Power Supply Universal Supply 85 to 250 VAC 21 to 10...

Страница 39: ...1 D Ex tb ia IIIC T90 C 30OC TAMB 70OC IP66 Temperature Class Process Temps Integral Sensor T5 100 C T4 135 C T3 200 C T2 230 C Reference control drawing 420 0004 563 CD for entity and installation re...

Страница 40: ...RNLXX1 IntelliPoint RF Series User s Manual 34 Section 6 Control Drawings Certificates 6 1 FM FMc Control Drawings...

Страница 41: ...Control Drawings 35 6 1 FM FMc Control Drawings Continued...

Страница 42: ...RNLXX1 IntelliPoint RF Series User s Manual 36 6 1 FM FMc Control Drawings Continued...

Страница 43: ...Control Drawings 37 6 1 FM FMc Control Drawings Continued...

Страница 44: ...RNLXX1 IntelliPoint RF Series User s Manual 38 6 1 FM FMc Control Drawings Continued...

Страница 45: ...Control Drawings 39 6 1 FM FMc Control Drawings Continued...

Страница 46: ...RNLXX1 IntelliPoint RF Series User s Manual 40 6 1 FM FMc Control Drawings Continued...

Страница 47: ...0 93 NN or ZZ 0 0 700 1202 021 2 700 1202 024 3 700 1202 028 4 700 1202 042 6 700 1202 032 7 700 1202 020 9 700 1202 034 1 1 700 0201 005 2 700 0201 005 HAST C 3 700 0201 019 4 700 0202 002 5 700 0202...

Страница 48: ...ANDARD RELAY 2 GOLD CONTACTS e f e f SENSING ELEMENTS 00 02 04 06 07 09 22 24 28 31 40 f 50 53 55 60 62 64 66 72 73 80 83 85 90 94 NN or ZZ 0 0 700 1202 001 2 700 1202 014 3 700 1202 018 4 700 1202 04...

Страница 49: ...002 2 700 0207 003 3 700 0207 004 5 700 0207 006 6 0 700 0204 038 1 700 0204 002 2 700 0204 048 4 700 0204 024 6 700 0204 022 7 700 3201 001 7 2 700 0201 027 3 700 0201 028 8 0 700 4200 020 1 700 4200...

Страница 50: ...OT APPLY TO SPECIAL SENSORS SUPPLIED WITHOUT A 285 SERIES SENSING ELEMENT ENCLOSURE SEE PAGE 14 FOR SPECIFIC CONDITIONS OF USE FM APPROVED ADDITIONAL SENSING ELEMENTS SHT 11 OF 14 420 0004 144 CD ISS...

Страница 51: ...SENSING ELEMENTS 00 02 04 06 07 09 11 19 21 24 25 28 72 73 86 87 90 93 0 0 700 1202 021 2 700 1202 024 4 700 1202 042 6 700 1202 032 7 700 1202 020 9 700 1202 034 1 1 700 0201 005 2 700 0201 005 HAST...

Страница 52: ...11 21 24 28 60 62 64 66 72 73 85 90 94 0 0 700 1202 001 2 700 1202 014 4 700 1202 041 6 700 1202 031 7 700 1202 010 9 700 1202 033 1 1 700 0201 005 2 700 0201 005 HAST C 3 700 0201 019 4 700 0202 002...

Страница 53: ...plosive dust atmosphere where high electrostatic charging processes are present that could result in propagating brush discharges See IEC TS60079 32 1 for additional guidance 2 Consult the manufacture...

Страница 54: ...RNLXX1 IntelliPoint RF Series User s Manual 48 6 2 ATEX Control Drawings...

Страница 55: ...Control Drawings 49 6 2 ATEX Drawings Continued...

Страница 56: ...L M20 HOUSING b b RELAYS 1 STANDARD RELAY 2 GOLD CONTACTS c d c d SENSING ELEMENTS 00 02 04 07 28 91 93 0 0 700 1202 021 KEMA 10ATEX0009 U 2 700 1202 024 KEMA 10ATEX0009 U 3 700 1202 028 KEMA 10ATEX00...

Страница 57: ...94 or ZZ 0 0 700 1202 001 KEMA 10ATEX0009 U 2 700 1202 014 KEMA 10ATEX0009 U 3 700 1202 018 KEMA 10ATEX0009 U 4 700 1202 041 KEMA 10ATEX0009 U 6 700 1202 031 7 700 1202 010 KEMA 10ATEX0009 U 9 700 120...

Страница 58: ...2 700 0207 003 3 700 0207 004 5 700 0207 006 6 0 700 0204 038 1 700 0204 002 2 700 0204 048 4 700 0204 024 6 700 0204 022 7 2 700 0201 027 3 700 0201 028 8 0 700 4200 020 1 700 4200 030 2 700 4200 04...

Страница 59: ...WITHOUT A 285 SERIES SENSING ELEMENT ENCLOSURE SEE PAGE 9 FOR SPECIFIC CONDITIONS OF USE ATEX APPROVED ADDITIONAL INTRINSICALLY SAFE SENSING ELEMENTS SHT 6 OF 9 420 0004 146 CD ISS 9 q FAMILY NUMBER 0...

Страница 60: ...TY 2 2 ATEX APPROVAL M20 HOUSING c c RELAYS 1 STANDARD RELAY 2 GOLD CONTACTS d e d e SENSING ELEMENTS 00 02 04 07 28 91 93 0 0 700 1202 021 KEMA 10ATEX0009 U 2 700 1202 024 KEMA 10ATEX0009 U 4 700 120...

Страница 61: ...202 041 KEMA 10ATEX0009 U 6 700 1202 031 7 700 1202 010 KEMA 10ATEX0009 U 9 700 1202 033 1 1 700 0201 005 2 700 0201 005 HAST C 3 700 0201 019 4 700 0202 002 5 700 0202 043 6 700 0002 360 7 700 0202 0...

Страница 62: ...d in an explosive dust atmosphere where high electrostatic charging processes are present that could result in propagating brush discharges See CLC TR 60079 32 1 for additional guidance 2 Consult the...

Страница 63: ...Control Drawings 57 6 3 CE Declaration of Conformity...

Страница 64: ...RNLXX1 IntelliPoint RF Series User s Manual 58 6 4 IECEx Control Drawings...

Страница 65: ...Control Drawings 59 6 4 IECEx Control Drawings Continued...

Страница 66: ...pF AUTO CAL V 10 pF FIXED P 0 5 pF FIXED HIGH SENSITIVITY b b OPTIONS 2 IECEx APPROVAL M20 HOUSING c c RELAYS 1 STANDARD RELAY 2 GOLD CONTACTS d d 0 2 9 SENSING ELEMENTS e e 0 4 7 8 SENSING ELEMENTS 0...

Страница 67: ...Z SENSING ELEMENTS f f 0 9 Z SENSING ELEMENTS 0 0 700 1202 001 2 700 1202 014 3 700 1202 018 4 700 1202 041 6 700 1202 031 7 700 1202 010 9 700 1202 033 1 0 700 0001 018 1 700 0201 005 2 700 0201 005...

Страница 68: ...5 0 700 0207 001 1 700 0207 002 2 700 0207 003 3 700 0207 004 5 700 0207 006 6 0 700 0204 038 1 700 0204 002 2 700 0204 048 4 700 0204 024 6 700 0204 022 7 2 700 0201 027 3 700 0201 028 8 0 700 4200 0...

Страница 69: ...SPECIAL SENSORS SUPPLIED WITHOUT A 285 SERIES SENSING ELEMENT ENCLOSURE IECEx APPROVED ADDITIONAL INTRINSICALLY SAFE SENSING ELEMENTS SHT 6 OF 9 420 0004 563 CD ISS 1 q FAMILY NUMBER 0 THROUGH 9 BLANK...

Страница 70: ...FIXED T 10 pF AUTO CAL V 10 pF FIXED P 0 5 pF FIXED HIGH SENSITIVITY c c OPTIONS 2 IECEx APPROVAL M20 HOUSING d d RELAYS 1 STANDARD RELAY 2 GOLD CONTACTS e e 0 2 9 SENSING ELEMENTS f f 0 4 7 8 SENSING...

Страница 71: ...00 1202 001 2 700 1202 014 4 700 1202 041 6 700 1202 031 7 700 1202 010 9 700 1202 033 1 1 700 0201 005 2 700 0201 005 HAST C 3 700 0201 019 4 700 0202 002 5 700 0202 043 6 700 0002 360 7 700 0202 029...

Страница 72: ...SSES ARE PRESENT THAT COULD RESULT IN PROPAGATING BRUSH DISCHARGES 2 CONSULT THE MANUFACTURER IF DIMENSIONAL INFORMATION ON THE FLAMEPROOF JOINTS IS NECESSARY 3 AMBIENT TEMPERATURE RANGE 30 C TO 58 C...

Страница 73: ...Control Drawings 67 6 5 Mounting and Wiring for Spark Protector Drawings...

Страница 74: ...RNLXX1 IntelliPoint RF Series User s Manual 68 6 5 Mounting and Wiring for Spark Protector Continued...

Страница 75: ...Control Drawings 69 6 5 Mounting and Wiring for Spark Protector Continued...

Страница 76: ...RNLXX1 IntelliPoint RF Series User s Manual 70 6 6 Adding a Padded Capacitor...

Страница 77: ...Control Drawings 71 6 6 Adding a Padded Capacitor Continued...

Страница 78: ...RNLXX1 IntelliPoint RF Series User s Manual 72 6 6 Adding a Padded Capacitor Continued...

Страница 79: ...Control Drawings 73 6 7 Dual Seal Assembly for 700 Series Sensing Elements...

Страница 80: ...RNLXX1 IntelliPoint RF Series User s Manual 74 6 7 Dual Seal Assembly Continued...

Страница 81: ...Control Drawings 75 6 7 Dual Seal Assembly Continued...

Страница 82: ...Appendix A...

Страница 83: ...discharge 5 Protect electronics from any heat Shortening The bare metal center rod of the sensing element can be shortened with a hacksaw Be careful not to cut either of the two insulators See Figure...

Страница 84: ...nt 3 Housing Any enclosure where the sensor and transmitter can be located 4 Non metallic applications any application where the sensor is not surrounded by a metallic surface C Installation Specifics...

Страница 85: ...metal housing i e typically explosion proof or weatherproof housings meet this requirement 5 Sensor Type Mounting In all non metallic applications the sensor must have a full concentric shield i e ne...

Страница 86: ...and to the ultimate country of destination specified on Order s or declared as the country of ultimate destination on Seller s invoices or in the End Use Statement that Buyer supplies Seller Seller s...

Страница 87: ...and other technical information supplied by Seller in connection herewith hereinafter called Data shall remain Seller s sole property and shall be held in confidence by Buyer Data shall not be reprod...

Страница 88: ......

Страница 89: ...eith Valley Road Horsham PA 19044 Telephone 1 215 674 1234 Fax 1 215 674 2731 E mail drexelbrook sales ametek com Website www drexelbrook com An ISO 9001 Certified Company RNLXX1 LM Issue 25 EDO 05 19...

Отзывы: