background image

 

Revised – June 2016

 

Troubleshooting 
 

 

 

POSSIBLE CAUSE 

OUT OF WARRANTY REMEDY *** 

IM

P

E

L

L

E

R

 D

O

E

S

 N

O

T

 

T

U

R

N

 

H

u

m

m

in

g

 S

o

u

n

d

 

1.  * One phase of power line not connected 
2.  * One phase of stator winding open 
3.  Bearings defective 
4.  Impeller jammed by foreign material 
5.  Impeller jammed against housing or cover 
6.  ** Capacitor open 

1.  Connect 
2.  Rewind or buy new motor 
3.  Change bearings 
4.  Clean and add filter 
5.  Adjust 
6.  Change capacitor 

N

o

 

S

o

u

n

d

 

1.  * Two phases of power line not connected 
2.  * Two phases of stator winding open 

1.  Connect 
2.  Rewind or buy new motor 

IM

P

E

L

L

E

R

 T

U

R

N

S

 

B

lo

w

n

 

F

u

s

e

 

1.  Insufficient fuse capacity 
2.  Short circuit 

1.  Use time delay fuse of proper 

rating 

2.  Repair 

M

o

to

O

v

e

rh

e

a

te

d

 O

P

ro

te

c

to

T

ri

p

s

 

1.  High or low voltage 
2.  * Operating in single phase condition 
3.  Bearings defective 
4.  Impeller rubbing against housing or cover 
5.  Impeller or air passage clogged by foreign material 
6.  Unit operating beyond performance range 
7.  Capacitor shorted 
8.  * One phase of stator winding short circuited 

1.  Check input voltage 
2.  Check connections 
3.  Check bearings 
4.  Adjust 
5.  Clean and add filter 
6.  Reduce system pressure/vacuum 
7.  Change capacitor 
8.  Rewind or buy new motor 

A

b

n

o

rm

a

S

o

u

n

d

 

1.  Impeller rubbing against housing or cover 
2.  Impeller or air passages clogged by foreign 

material 

3.  Bearings defective 

1.  Adjust 
2.  Clean and add filter 
3.  Change bearings 

P

e

rf

o

rm

a

n

c

e

 

B

e

lo

w

 S

ta

n

d

a

rd

 

1.  Leak in piping 
2.  Piping and air passages clogged 
3.  Impeller rotation reversed 
4.  Leak in blower 
5.  Low voltage 

1.  Tighten 
2.  Clean 
3.  Check wiring 
4.  Tighten cover, flange 
5.  Check input voltage 

* 3 phase units 
** 1 phase units 
*** Disassembly and repair of new blowers or motors will void the Rotron warranty.  Factory should be contacted 

prior to any attempt to field repair an in-warranty unit. 

Blower Disassembly: 

WARNING:  Attempting to repair or diagnose a blower may void Rotron’s warranty.  It may also 
be difficult to successfully disassemble and reassemble the unit. 

1)  Disconnect the power leads. CAUTION:  Be sure the power is disconnected before doing any work 

whatsoever on the unit. 

2)  Remove or separate piping and/or mufflers and filters from the unit. 

3)  Remove  the  cover  bolts  and  then  the  cover.  NOTE:    Some  units  are  equipped  with  seals.    It  is 

mandatory that these seals be replaced once the unit has been opened. 

4)  Remove the impeller  bolt  and  washers  and  then remove  the impeller.  NOTE:   Never  pry  on  the 

edges of the impeller. Use a puller as necessary. 

5)  Carefully note the number and location of the shims.  Remove and set them aside.  NOTE:  If the 

disassembly  was  for inspection  and  cleaning the  unit may  now  be  reassembled  by  reversing  the 
above steps.  If motor servicing or replacement and/or impeller replacement is required the same 
shims  may  not  be  used.    It  will  be  necessary  to  re-shim  the  impeller  according  to  the  procedure 
explained under assembly. 

 

Содержание DR1233

Страница 1: ...TS MANUAL FOR BLOWER MODEL DR633 DR833 DR1233 DIRECT DRIVE REGENERATIVE BLOWER AMETEK Dynamic Fluid Solutions 100 East Erie St Kent Ohio 44240 Telephone 330 673 3452 Fax 330 677 3306 email dfs informa...

Страница 2: ...ures due to abuse misuse misapplication or repeat offense will not be covered AMETEK Rotron will then notify you of your options Any failed unit that is tampered with by attempting repair or diagnosis...

Страница 3: ...at the blower outlet or inlet Also if problems do arise the Rotron Field representative will need to know the operating pressure suction to properly diagnose the problem 6 Excess Air Bleed excess air...

Страница 4: ...and add filter 3 Change bearings Performance Below Standard 1 Leak in piping 2 Piping and air passages clogged 3 Impeller rotation reversed 4 Leak in blower 5 Low voltage 1 Tighten 2 Clean 3 Check wir...

Страница 5: ...er pads over the screens 3 Reassemble by reversing the procedure NOTE On DR068 models with tubular mufflers it is necessary to remove the cover and impeller accessing the muffler material from the hou...

Страница 6: ...the flange face to the motor shaft shoulder B Impeller Thickness C Measurements A and B are made by laying the parallel bar across the housing flange face and measuring to the proper points Each meas...

Страница 7: ...E ROTATION D 1 EMERSON 1 8 HP MOTOR 115 VAC 230 VAC P1 BLUE LINE P1 BLUE LINE P2 BROWN 5 BLACK 5 BLACK 3 ORANGE 3 ORANGE 2 WHITE 4 YELLOW P2 BROWN INSULATE 2 WHITE LINE 4 YELLOW LINE RED RED INTERCHAN...

Страница 8: ...22 23 35 36 37 25 2 3 29 30 25 26 24 1 34 27 31 37 5309 15 16 17 18 11 8 9 10 IN 22 23 5 4 6 7 41 39 40 20 21 12 13 14 12 4 14 3 13 LIPSEAL DETAIL SCALE 2 1 D 33 32 DR633 AND DR833 ASSEMBLY DRAWING...

Страница 9: ...OUT 37 38 5309 30 27 1 20 21 34 33 32 37 2 3 11 8 9 10 5 4 6 7 40 16 18 17 15 31 LIPSEAL DETAIL SCALE 2 1 13 14 12 12 13 14 35 29 36 39 41 47 42 46 45 44 43 24 DR1233 ASSEMBLY DRAWING...

Страница 10: ...5 2 552141 552141 552141 552141 552142 16 9 155356 155356 155356 155356 155356 17 2 552143 552143 552143 552143 552144 18 8 155356 12 155356 155356 155356 155356 19 Not used Not used Not used Not used...

Страница 11: ...5668 36 1 155581 Not used 155581 Not used 155582 37 8 155419 4 155419 155419 155419 155363 38 Not used Not used Not used Not used Not used 39 3 155354 155646 155354 155646 4 155646 40 3 155380 155380...

Страница 12: ...103 C 515255 552618 552104 G 515255 552618 552101 C 515255 552618 DR833AY86 552102 G 515255 552101 C 515255 552102 G 515255 552099 C 515255 552103 C 515255 552104 G 515255 552101 C 515255 DR833AY86M 5...

Страница 13: ...As needed Viewed looking at inlet outlet ports 5 31 16 REV E...

Страница 14: ...As needed Viewed looking at inlet outlet ports 5 31 16 REV E...

Страница 15: ...As needed Viewed looking at inlet outlet ports 5 31 16 REV E...

Отзывы: