background image

SERIES 925 (A1 & A2) 
INSTALLATION & SERVICE BULLETIN

 

                               

 

 

 

1080 N. Crooks Road, Clawson, MI 48017-1097 

Phone  (248) 435-0700     FAX  (248) 435-8120

 

For Sales & Technical Assistance Call 800-635-0289

 

 A Product of

 

 

FORM1054 
Rev. B 
5/1/03

 

 

The instructions that follow are intended for 
use with the 925 A1 and 925 A2 models.  
They also are to be used for all outputs 
whether Patriot Sensors & Controls resolver, 
potentiometers, encoders, or customer 
resolvers. The latter will also have additional 
installation instructions.

 

 

INSTALLATION:

 

 
The 925 may be mounted in any position, 
except for the two shown in 

Fig. 1

  (Please 

note the qualifier for the two positions.) 

5/16”

 

dia. bolts are the preferred choice for 
securing the unit to the base to which it is 
mounted.

 

 

Fig. 1  

Positions not recommended 

without external cable support.

 

Cable attachment is with the .19” dia. pin 
provided on the cable end assembly. The 
rubber bumper on the cable serves as a stop 
for initial cable tension. The 925 unit is 
shipped with the correct spring tension 
applied (see 

Important Note

  under 

SPRING 

TENSION ADJUSTMENT 

section for 

information regarding spring tension). If 
spring adjustment is absolutely necessary, 
please see 

SPRING TENSION 

ADJUSTMENT 

for proper tension adjusting 

instructions.   

 

If the 925 was ordered with initial cable lead,  
the length will be marked with a steel clip. 

Do 

not 

remove the top cover during installation. 

 
If the unit has a standard Patriot Sensors & 
Controls resolver installed, an input 
connector plug (see drawing #

SD0296000

) is 

included along with a wiring diagram (see 
drawing #

SD0308900

) for the multiconductor 

cable. 
 
 
 
 
 
 
 
 
 
 
 
 
 

CABLE REPLACEMENT: 

 

TOOLS REQUIRED: 

  

 5/64” ALLEN WRENCH 

  

 FLAT BLADE SCREWDRIVER

 

 
1) Remove the top cover and release spring 
tension, if any (see 

SPRING TENSION 

ADJUSTMENT 

section ). Between the top 

cover and the spring housing there is an 
access hole 

(see

 

Fig. 2)

 

Fig. 2 

 Location of screw access hole. 

Rotate the drum until the end of a button 
head socket screw appears (by looking 
through the access hole). Remove this screw 
with the Allen wrench (

NOTE:

  Care must be 

taken when removing the screw so as to 
prevent the screw from falling off inside the 
enclosure). Pull all remaining cable free from 
the drum. 
 
2) The new cable end should lay in the 
machined pocket on the drum 

(see

 

Fig. 3)

.  

Re-insert screw through cable end eye and 
into threaded hole on drum with Allen wrench 
and tighten. 

 

Fig. 3  

Location of pocket on cable 

drum. 

Test the integrity of the cable anchor by 
tugging on the cable once or twice. 
 
3) To wind the new cable on the drum easily, 
the recoil springs(s) should be disconnected 
from the drum shaft. See 

SPRING TENSION 

ADJUSTMENT 

section for instructions on 

how to disconnect the spring(s). 
 
4) After the spring(s) have been 
disconnected, rotate the drum until all the 
cable has been stored. Make sure that the 
cable is fed into the first drum groove 
correctly. If not, the cable will interfere with 
the cable guide (gray steel bar across drum) 
and affect the operation of the unit. 
 
 

5) Adjust spring tension (see item 3 under 

SPRING TENSION ADJUSTMENT

) and then 

reassemble the rest of the 925 unit. 

SPRING TENSION ADJUSTMENT 
and REPLACEMENT

 

TOOLS REQUIRED: 

 

 3/32” ALLEN WRENCH 

 

 SMALL FLAT BLADE  
 SCREWDRIVER

 

 

Important Note: 

 

The following instructions should be used 
only after repair or other remedial attention 
has been given to the 925. Tension adjusting 
is 

not

  necessary at the time of initial 

installation since the proper tension has been 
set before shipment.  Increasing spring 
tension is not the answer to erratic recoil 
action since it only serves to mask the real 
problem. Increasing spring tension decreases 
cycle life.  Carried to the extreme, it will pull 
the cable out of the cable anchor, break the 
spring through overload, or some similar 
failure. 

These types of failures are not 

covered by the warranty. 

 
1) For safety reasons, all spring tension 
adjustments should be conducted with the 
cable retracted on the drum. At this time the 
stored energy is at a minimum.  
 
2) Loosen two of the three servo clamp 
screws with the Allen wrench 

(see

 

Fig. 4)

Grasp the spring housing firmly while 
loosening the third screw. Relax any residual 
tension.  If spring removal and installation is 
not required, refer to Item  3 of this section for 
remaining tension adjustment instruction. 
 
3) With the three servo clamp screws 
installed, but not tightened, the cast 
aluminum spring housing for the A1 model 
and the plastic housing of the A2 should be 
grasped firmly and rotated 

clockwise.

  The 

rotation is 10 turns for the A1 and 15 turns for 
the A2 model. Secure the three servo clamp 
screws. 

 

SPRING REMOVAL: A1

 

 
The spring housing assembly may be freed 
by removing all three servo clamp screws.  
Grasp spring cover, which is an aluminum 
casting, and pull cover and spring free from 
drum shaft roll pin 

(see

 

Fig. 4)

. (

CAUTION:

 

Cover and spring must be removed together 
as 

one

  unit.)  Spring may now be removed 

for inspection or replacement by 
disconnecting spring tang from the cover.  
 

CAUTION:

  On reassembly, make sure hook 

tang faces the same direction that it did at 
disassembly. 

 
 
 
 
 
 
 

Отзывы: