Health and Safety Information

Read all of the instructions in this booklet - including all the WARNINGS and CAUTIONS 

before

 using this product. If there is any instruction which you do not understand, DO 

NOT USE THE PRODUCT.

Safety Signs

WARNING

Indicates a potentially hazardous situation which, if not avoided, could result in death or 

personal injury.

CAUTION

Indicates a potentially hazardous situation which, if not avoided, could result in minor or 

moderate injury to the user or users, or result in damage to the product or to property.

NOTE

Indicates a potentially hazardous situation which, if not avoided, could result in damage or the loss of 

data.

Signs and Symbols used on equipment and Documentation

Caution, risk of electric shock.

Caution, attention to possibility of risk of damage to the product, process or surroundings. Refer 

to instruction manual.

Caution, hot surface.

Protective Conductor Terminal.

Observe precautions for handling electrostatic discharge sensitive devices.

Equipment Operation

Use of this instrument in a manner not specified by Land Instruments International may be hazardous. 

Read 

and understand

 the user documentation supplied 

before

 installing and operating the equipment.

The safety of any system incorporating this equipment is the responsibility of the assembler.

Protective Clothing, Face and Eye Protection

It is possible that this equipment is to be installed on, or near to, machinery or equipment operating at 

high temperatures and high pressures. Suitable protective clothing, along with face and eye protection 

must be worn. Refer to the health and safety guidelines for the machinery/equipment before installing 

this product. If in doubt, contact Land Instruments International.

Electrical Power Supply

Before working on the electrical connections, all of the electrical power lines to the equipment must 

be isolated. All the electrical cables and signal cables must be connected exactly as indicated in these 

operating instructions. If in doubt, contact Land Instruments International.

Storage

The instrument should be stored in its packaging, in a dry sheltered area.

Unpacking

Check all packages for external signs of damage. Check the contents against the packing note.

Lifting Instructions

Where items are too heavy to be lifted manually, use suitably rated lifting equipment. Refer to the 

Technical Specification for weights. All lifting should be done as stated in local regulations.

IMPORTANT INFORMATION - PLEASE READ

Contact Us

UK - Dronfield

Land Instruments International

Tel:       +44 (0) 1246 417691
Email:   [email protected]
Web:     www.landinst.com

USA - Pittsburgh

AMETEK Land, Inc.

Tel:      +1 412 826 4444
Email:  [email protected] 
Web:    www.ametek-land.com

China

AMETEK Land

 China Service 

Tel: 

+86 21 5868 5111 ext 122

Email:   [email protected]
Web:     www.landinst.com

India

AMETEK Land

 India Service

Tel:     +91 - 80 67823240 
Email:  [email protected]
Web:    www.landinst.com

For further details on all AMETEK Land offices, distributors and representatives, please visit 

our websites.

Return of Damaged Goods

IMPORTANT If any item has been damaged in transit, this should be reported to the carrier and to the 

supplier immediately. Damage caused in transit is the responsibility of the carrier not the supplier.
DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim. Save 

the packing with the damaged article for inspection by the carrier.

Return of Goods for Repair

If you need to return goods for repair please contact our Customer Service Department. They will be able 

to advise you on the correct returns procedure.

Any item returned to Land Instruments International should be adequately packaged to prevent damage 

during transit.
You must include a written report of the problem together with your own name and contact information, 

address, telephone number, email address etc.

Design and Manufacturing Standards

The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for 

the design, manufacture and on-site servicing of combustion, environmental monitoring and non-contact 

temperature measuring instrumentation. 

Approvals apply in the USA

Operation of radio transmitters, telephones or other electrical/electronic devices in close proximity 

to the equipment while the enclosure doors of the instrument or its peripherals are open, may cause 

interference and possible failure where the radiated emissions exceed the EMC directive.

 

The protection provided by this product may be invalidated if alterations or additions are made to the 

structural, electrical, mechanical or pneumatic parts of this system. Such changes may also invalidate the 

standard terms of warranty.

Copyright

This manual is provided as an aid to owners of Land Instruments International’s products and contains 

information proprietary to Land Instruments International. This manual may not, in whole or part, be 

copied, or reproduced without the expressed written consent of Land Instruments International Ltd.

Copyright © 2016 Land Instruments International.

MARCOM0311, Issue 7, 01 November 2016

Approvals apply in India

Содержание CDA

Страница 1: ...Incinerator Thermometer User Guide Issue 5 04 January 2017 Publication N 800682 Language English CDA Copyright 2002 2017 Land Instruments International...

Страница 2: ...e user documentation supplied before installing and operating the equipment The safety of any system incorporating this equipment is the responsibility of the assembler Protective Clothing Face and Ey...

Страница 3: ...ent damage during transit You must include a written report of the problem together with your own name and contact information address telephone number email address etc Design and Manufacturing Stand...

Страница 4: ...Thermometer User Guide CDA...

Страница 5: ...2 Aiming Consideration 5 4 Using the Thermometer 8 4 1 Location of Controls 8 4 2 Adjusting the Emissivity Value 9 4 3 Adjusting the Averager Response Time 10 4 4 Noting Emissivity and Response Time S...

Страница 6: ...Thermometer User Guide CDA...

Страница 7: ...on is contained within the LAND CDA Incinerator Thermometer Installation Guide All User Guides Installation Guides and Instruction Leaflets supplied should be read thoroughly before proceeding with an...

Страница 8: ...incinerator wall positioned approximately 2 metres above the bed It is fixed to a protective flanged sight tube which penetrates through the incinerator wall The thermometer sight path acts as an inv...

Страница 9: ...Assembly dimensions 294004 600mm 23 6in Parallel FOV 20mm 0 79in Lens Diverging FOV Thermometer removal clearance Approx 200 8 0 Side View 150 5 9 170 6 7 110 4 4 117 4 6 Top View 120 4 7 430 17 0 Al...

Страница 10: ...sponse Time 3t 1 to 10s adjustable Resolution 0 5 C 1 F Accuracy absolute 0 5 Kelvin over 600 to 1600 C 1112 to 2912 F 1 Kelvin over 400 to 600 C 752 to 1112 F 1 Kelvin 1600 to 1800 C 2912 to 3292 F D...

Страница 11: ...Fig 6 shows recommended minimum internal diameter versus tube length reasonable allowance is included here for misalignments The instrument responds to hot CO2 in the atmosphere To obtain an accurate...

Страница 12: ...nded Sight Tube diameters 294006 70 60 50 40 30 20 10 0 0 100 200 300 400 500 600 700 800 Sight tube length mm Minimum internal diameter mm Path length metres Error C 0 50 100 150 200 8 7 6 5 4 3 2 8...

Страница 13: ...DA Fig 8 Thermometer error at 1200K gas temperature 294008 Path length metres Error C 0 50 100 150 200 8 7 6 5 4 3 2 8 CO2 6 CO2 4 CO2 2 CO2 Thermometer error versus path length for several CO2 concen...

Страница 14: ...d in a location which is difficult to access and or used in conjunction with a jacket and back cap 4 1 Location of Controls The Emissivity and Response Time control switches are located on the rear fa...

Страница 15: ...notes the first figure after the decimal point of the emissivity value e g for an emissivity value of 0 85 set SW1 to 8 and SW2 to 5 When switch SW1 is set to 0 this denotes a 1 before and a 0 after t...

Страница 16: ...to the CDA For further information contact Land Instruments International To adjust the Averager Response Time function use the potentiometer P1 see Fig 10 The Response Time value can be set to betwe...

Страница 17: ...of the settings for Emissivity and Response Time once these settings have been determined and verified Each time a re adjustment is made to the settings make a note in the table below using the space...

Страница 18: ...from a predefined target area onto an infrared detector This detector converts the incoming infrared radiation into a low level electrical voltage which is proportional to the temperature of the targe...

Страница 19: ...through the plug housed in the protective jacket back cap To connect either plug type to the thermometer socket Align the red marker near the lugs of the plug with the red marker located above the ke...

Страница 20: ...on how to adjust thepower supply voltage for a LAND power supply is given in the Power Supply Unit User Guide Fig 13 Graph showing load resistance versus power supply voltage 294013 NOTE The system lo...

Страница 21: ...4 Thermometer Mountings and Accessories Installation Guide 6 2 Sighting Tubes It is normal to use a sighting tube to penetrate the incinerator wall The thermometer jacket is then bolted to a flange at...

Страница 22: ...kept clean and free from contaminants and that all services to the system water and air supplies are set correctly and are routinely checked For further information detailing services supplied to any...

Страница 23: ...ruments based on System 4 UNO thermometers accessories and mountings and special instruments based on UNO Application dedicated processors based on LANDMARK Graphic ABTS S and ABTS U FTS VDT S and VDT...

Страница 24: ...utside the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral pH etc overh...

Отзывы: