Measurement Operation

note:

  Remove plugs from 

ends of Test Leads (included) 
before connecting to Meter.

note:

  Test Lead probes have 

removable covers for overvoltage 
protection.  With covers in place, Test 
Leads are rated for use with CAT III 
and CAT IV circuits.  Exposed probes 
are rated for use with CAT II circuits.

ac/Dc Voltage Measurement

Measure AC conductors carrying up to 750 VAC, 45Hz ~ 1kHz.

Measure DC conductors carrying up to 1000 VDC.

WarninG!

  

use caution when working 

near voltages above 30 Vac rms, 
42 Vac peak, or 60 VDc.  Voltages this 
high present a risk of electric shock.

1.  Plug black test lead into 

cOM

 Jack.  

Plug red test lead into  

V

Hz

 

input

 Jack.

2.  Turn Rotary Switch to the 

Hz %

 or 

mV 

Hz %

 

position, as appropriate.

3.  Press 

Blue

 Button to choose 

AC or DC voltage.

4.  Carefully touch exposed 

conductors with tips of probes.

5.  Read measured voltage on the Display. 

6.  Press 

Hz%

 to obtain frequency 

and duty cycle value.

7.  When testing is complete, turn 

Rotary Switch to 

OFF

, remove 

Test Leads and store with Meter.

Frequency/Duty cycle Measurement

Measure a signal’s duty cycle and frequency from 10Hz to 10MHz.

1.  Plug black test lead into 

cOM

 Jack.  

Plug red test lead into  

V

Hz input

 Jack.

2.  Turn the Rotary Switch to the 

Hz% 

position.  Frequency (Hz) is the 
default measurement mode.

3.  Connect the Test Leads across 

the circuit to be measured.

4.  Read measured frequency 

on the Display.

5.  To measure 

Duty cycle

, press the 

Hz%

 Button to select 

%

 measurement.

6.  When testing is complete, turn 

Rotary Switch to 

OFF,

 remove 

Test Leads

 

and store with Meter.

Содержание 64021

Страница 1: ...ence 18k When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2018 by Harbor Freight Tools All...

Страница 2: ...sed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will resul...

Страница 3: ...the Meter have it serviced before use f The battery cover is open 5 Power this Meter using only the battery ies referenced in the Specifications Chart 6 Use caution when working near voltages above 3...

Страница 4: ...ter may vary depending on battery condition 24 Use the proper settings terminals techniques and range for the tests performed Start with the range stated in the instructions 25 Do not apply voltage to...

Страница 5: ...nt Accuracy 600 A 6000 A 1 2 of rdg 5D 60mA 600mA 1 5 of rdg 5D 6A 10A 2 0 of rdg 5D Resistance Ranges 600 6k 60k 600k 6M 60M Resistance Accuracy 600 1 2 of rdg 2D 6k 600k 1 0 of rdg 2D 6M 1 2 of rdg...

Страница 6: ...ing of this manual including all text under subheadings therein before set up or use of this product Functions Milli Micro amp temperature input Jack common input Jack capacitance Volts Ohms Frequency...

Страница 7: ...selection mode Continuity Diode test rEL Relative measurement mode MaX The maximum value is being measured Min The minimum value is being measured Battery low Percent Duty cycle c F Celsius Fahrenheit...

Страница 8: ...aX Min Button The MaX Min Button allows you to record temporarily store and view signal events as you monitor them You may record while in any range or mode except Hz frequency duty cycle 1 Press the...

Страница 9: ...ote The Hold mode will not capture unstable or noisy readings 4 To turn on the Display s backlight hold down the HOLD LiGHt Button for about 2 seconds 5 The backlight will automatically turn off after...

Страница 10: ...Plug red test lead into V Hz input Jack 2 Turn Rotary Switch to the V Hz or mV Hz position as appropriate 3 Press Blue Button to choose AC or DC voltage 4 Carefully touch exposed conductors with tips...

Страница 11: ...modes resistance Measurement Measure resistance up to 60M Ohms WarninG to prevent electric shock turn off all power and fully discharge capacitors in the circuit under test before measuring note When...

Страница 12: ...store with Meter note If Test Leads are open or the resistance is out of range OL is displayed The buzzer does not sound if the resistance is greater than 100 Diode Measurement Test voltage drop in di...

Страница 13: ...fore measuring 1 Plug black test lead into cOM Jack Plug red test lead into V Hz input Jack 2 Turn the Rotary Switch to the position 3 Press Blue Button until nF is displayed 4 Press the rEL button to...

Страница 14: ...he circuit and allow capacitors to discharge 4 Press Blue Button to select AC or DC current The Meter default is DC current measurement 5 Break the circuit and connect the Test Leads in series with th...

Страница 15: ...cement If the sign appears on the Display the battery should be replaced 1 Remove Test Leads from the Meter 2 Power off Meter and turn it over 3 Remove screw s Remove tilt stand and battery cover 4 Re...

Страница 16: ...you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be...

Отзывы: