Page 7
For technical questions, please call 1-888-866-5797.
Item 64001
Sa
F
ety
Opera
ti
O
n
Maintenance
Setup
error Messages
The following error messages may appear on the Display during operation:
error code
cause
Solution
err01
The reflected laser signal is too strong�
Change target or affix a white
sheet of paper to target�
err02
The distance to be measured falls outside
the measuring range for this device�
Measure within the effective
measuring range (0�16’ ~ 98�43’)�
err03
The reflected laser signal is too weak�
Change target or affix a white
sheet of paper to target�
err06
Low battery�
Replace battery� See “Battery
Replacement” on page 7below�
Maintenance and Servicing
procedures not specifically explained in this manual
must be performed only by a qualified technician.
cleaning, Maintenance, and Lubrication
1� Wipe unit with a dry, lint-free cloth�
Do not use solvents or abrasives�
2� Remove battery if not in
use for long periods�
3� Store unit in a dry location�
4� Other than the battery, there
are no replaceable parts on this
unit�
repairs should be done
by a qualified technician.
Battery replacement
If the
sign appears on the
Display or the unit will not turn on,
the battery should be replaced�
1� Turn the unit over�
2� Remove battery cover carefully�
3� Pull batteries out of unit and
replace with same�
note:
Do not reverse the
polarity of the batteries�
4� Replace cover and retighten screw�
calibration
Have the Meter calibrated by a qualified technician every year�