background image

Page 6

For technical questions, please call 1-888-866-5797.

Item 57716

SA

FETY

OPERA

TI

O

N

MAINTENANCE

SETUP

Operating Instructions

  Read the ENTIRE IMPORTANT SAFETY INFORMATION section 

at the beginning of this manual including all text under 

subheadings therein before set up or use of this product.

Electrical shock can cause death or injury! NEVER TOUCH 

exposed conductors of electricity

.

General Operating Instructions

1.  Connect the Power Input Plug 

into a grounded 120VAC outlet.

2.  Devices with standard 

AC plugs can be tested:

Standard AC Plugs

3.  To test the working 

current

 

of the connected device:
a.  Turn the device’s power switch 

to OFF and connect it to the 

Input Socket of the AC Line Splitter.

b.  Set Clamp Meter (sold separately) 

to read AMPS and clamp it around 

the X1 (normal current load) 

or X10 (ten times the normal 

current load) test terminal.

Note:

  When using x10 position, 

divide reading on Clamp Meter by 

10 to obtain correct reading.

120VAC Outlets

Power cord from 

device under test

Clamp Meter

AC Line Splitter

c.  Power on the device and read 

the result on the Clamp Meter.

d.  When finished, turn the device’s 

power switch OFF and then 

remove the Clamp Meter.

e.  Unplug the device and then 

unplug the AC Line Splitter.

4.  To test the 

voltage

 of the 

connected device:
a.  Set multimeter (sold separately) 

to read AC VOLTS, and 

then plug it’s test leads into 

the AC Voltage Test Jacks 

on the AC Line Splitter.

b.  Turn the device’s power switch 

to OFF and connect it to the 

Input Socket of the AC Line Splitter.

c.  Power on the device and read 

the result on the multimeter.

d.  When finished turn the device’s 

power switch OFF and remove 

it from the AC Line Splitter.

e.  Unplug the AC Line Splitter 

and then remove the 

multimeter’s test leads.

5.  When finished, unplug the 

AC Line Splitter and store indoors 

out of children’s reach.

Note:

  To calculate 

power 

(wattage) of the connected device, 

multiply voltage by current.

Power = voltage x current

Содержание 57716

Страница 1: ...ence 21h When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2021 by Harbor Freight Tools All...

Страница 2: ...ed to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death Indicates a hazardous situation which if not avoided will result...

Страница 3: ...tch what you are doing use common sense Do not operate any ac line splitter when you are tired 7 Do not operate AC Line Splitter if under the influence of alcohol or drugs Read warning labels on presc...

Страница 4: ...r technical questions please call 1 888 866 5797 Item 57716 SAFETY OPERATION MAINTENANCE SETUP Specifications Maximum Test Input 125 VAC 50 60Hz 15A Safety Rating CAT II 600V Measurement Sensitivity x...

Страница 5: ...Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product Functions N Neutral E Earth Groun...

Страница 6: ...ng x10 position divide reading on Clamp Meter by 10 to obtain correct reading 120VAC Outlets Power cord from device under test Clamp Meter AC Line Splitter c Power on the device and read the result on...

Страница 7: ...tenance and Lubrication 1 Wipe unit with a dry lint free cloth Do not use solvents or abrasives 2 Store AC Line Splitter in a dry location 3 There are no replaceable parts on this AC Line Splitter Rep...

Страница 8: ...amages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS T...