Valve INV-907
Instructions 56-8101-01 Edition AC

7

Accessories and spare parts

Item

Quantity  Code no.
per pack

Valve INV-907 including

one UniNet cable
(fill port, needle and
syringe holder are
not included)

1

18-1108-40

Injection kit INV-907

including fill port
needle and syringe
holder

1

18-1110-89

Valve kit INV-907

including channel plate
and distribution plate

1

18-1109-05

Sample loops

100 µl

1

18-1113-98

500 µl

1

18-1113-99

1 ml

1

18-1114-01

2 ml

1

18-1114-02

Superloop, 10 ml

1

18-1113-81

Superloop, 50 ml

1

18-1113-82

Superloop, 150 ml

1

18-1023-85

Cable UniNet, 0.7 m

1

18-1109-74

Mounting bracket

1

18-1109-11

Teflon tubing, i.d. 1/8", 

o.d. 3/16"

3 m

18-1112-47

Tubing connector for 3/16" 

o.d. tubing

10

18-1112-49

Ferrule for 3/16" o.d.tubing

10

18-1112-48

Stop plug, 5/16”

5

18-1112-50

Stop plug, 1/16"

5

18-1112-52

Union Luer 

female/1/16" male

2

18-1112-51

Union 

1/16" female/M6 male

6

18-1112-57

Union 

M6 female/1/16" male

8

18-1112-58

PEEK tubing, i.d. 0.75 mm,

o.d. 1/16"

2 m

18-1112-53

Teflon tubing, i.d. 0.75 mm,

o.d. 1/16"

2 m

18-1112-54

PEEK tubing, i.d. 1.0 mm, 

o.d. 1/16"

2 m

18-1115-83

Fingertight connector 1/16"

10

18-1112-55

56-8101-01_AC.qxd  1998-10-26 11:45  Sida 7 (1,1)

Содержание INV-907

Страница 1: ...the valve 1 Connect the valve with two UniNet cables as a part of the UniNet 2 chain 2 Set the ID switch at the bottom to the required valve number 0 9 The number should correspond to that used in UN...

Страница 2: ...3 Operation The valve is controlled from UNICORN When used as an injection valve use the instruction InjectionValve in System Control Manual Flowpath The valve can be set in 3 positions LOAD position...

Страница 3: ...op volume Complete filling 2 5 times the sample loop volume Partial Filling Partial filling is used when high recovery is required Partial filling allows the injected volume to be changed without chan...

Страница 4: ...pprox 5 times the sample loop volume should be used to flush the loop and ensure that all sample is injected onto the column Storage Overnight The valve can be left filled with a buffer Weekend or Lon...

Страница 5: ...socket 2 Check the ID switch on the valve The ID number should correspond to the number set in UNICORN 3 Check the UniNet cable and replace if required The valve is switching to wrong position The val...

Страница 6: ...ysical data Internal volume Pos 1 LOAD Port 1 7 9 l Port 2 3 5 l Port 4 6 8 l Pos 2 INJECT Port 1 2 7 l Port 3 5 6 l Port 6 7 9 l Pos 3 WASH Port 2 4 8 l Port 5 7 9 l Flow channel diameter 0 8 mm Valv...

Страница 7: ...1 18 1113 81 Superloop 50 ml 1 18 1113 82 Superloop 150 ml 1 18 1023 85 Cable UniNet 0 7 m 1 18 1109 74 Mounting bracket 1 18 1109 11 Teflon tubing i d 1 8 o d 3 16 3 m 18 1112 47 Tubing connector for...

Страница 8: ...Biotech SE 751 84 Uppsala Sweden Trademarks KTA and UNICORN are trademarks of Amersham Pharmacia Biotech Limited or its subsidiaries Amersham is a trademark of Nycomed Amersham plc Pharmacia and Drop...

Отзывы: