background image

Resin Pack Regeneration 

Regeneration certificates are used to simplify the exchange of your exhausted 
resin packs.  Simply follow these four steps: 

1.  Place an order for your future supply of regeneration certificates.  Our 

minimum order is three (3) certificates. 

2.  Clearly print your name and address on the certificate and enclose it along 

with the exhausted resin pack that you are returning.  For your convenience, 
these instructions are printed along the bottom of each certificate. 

3.  When your resin pack is received at the center, a new pack will be sent to you 

using the certificate you’ve enclosed with your shipment. 

4.  AmeriWater recommends that you return your exhausted resin immediately 

after you change packs.  This will allow ample time for return shipment. 

With this program, you are billed at the time you order the regeneration 
certificates.  This eliminates the need for any extra paperwork and phone calls 
when your resin pack needs to be exchanged. 

Содержание OH 45414

Страница 1: ...Wall Mount Deionizer USER S GUIDE AND INSTALLATION MANUAL Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414 98 0028B...

Страница 2: ...Contents Your Deionizer System 1 Installation 3 Start Up 5 Resin Pack Exchange 6 Resin Pack Regeneration 7 Servicing your Deionizer System 8 Facts to Remember 9 Parts List 10...

Страница 3: ...te deionization and how it works we must first look at the contaminants found in our water supply and what purification processes may be needed in addition to deionization to provide the level of wate...

Страница 4: ...l charge their presence is directly related to the ability of the water to conduct electricity conductivity Conversely their relative absence is directly proportional to the water s inability to condu...

Страница 5: ...red if your pressure exceeds 65 psi WARNING Do not exceed 65 psi feed pressure or damage to the system and personal injury may occur 5 The maximum flow for each deionizer is 1 GPM If the flow increase...

Страница 6: ...om of the deionizer to the floor to allow for the removal of the deionizer housing for resin pack exchange Additional space may be required if you intend to drain the system into a bucket 3 Using the...

Страница 7: ...fitting 5 Remove the tubing from the deionizer outlet isolation valve and place it in a bucket or direct to a drain 6 Open the inlet isolation valve slowly to start water flow to the deionizer 7 Allow...

Страница 8: ...resin pack and install a new resin pack 6 Follow the start up procedures to pressurize system before use a Attach the deionizer body back onto the cap and reconnect the tube fitting and remove the tub...

Страница 9: ...are returning For your convenience these instructions are printed along the bottom of each certificate 3 When your resin pack is received at the center a new pack will be sent to you using the certifi...

Страница 10: ...you can smell the chlorine 5 Turn off the water and allow the system to stand for 15 minutes 6 After 15 minutes turn the water supply on to flush out your deionizer Allow water to flow until you can n...

Страница 11: ...nge process by passing the water through ion exchange resins that draw the ions from the water and replaces them with hydrogen and hydroxyl ions which subsequently join to become water 2 The ion excha...

Страница 12: ...10...

Страница 13: ...to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain PVC...

Отзывы: