AMERITRON ARI-500 Скачать руководство пользователя страница 3

ARI-500 Automatic Band Switch for ALS-500/600 

Instruction Manual 

 

Installation 

The ARI-500 connects to the REMOTE A/B jacks on the front of the amplifier.  Two RJ-45 cables are supplied to connect jack A 
and B from the ARI-500 to the REMOTE A/B jacks on the ALS-500M or ALS-600. 
 
1.

 

Place the ARI in a suitable location. 

2.

 

Ensure the amplifier power switch is OFF and the amplifier’s frequency select switch is in the REMOTE position. 

3.

 

Plug one of the patch cords into AMP A on the ARI-500.  Route the other end to the amplifier and connect it to the REMOTE 
A amplifier input. 

4.

 

Plug the other patch cord into AMP B on the ARI-500.  Route the other end to the amplifier and connect it to the REMOTE B 
amplifier input. 

 
Operating ALS-500RC with the optional ARI-500  

Skip this section and go to 

ARI-500 Transceiver Compatibility

 if the ALS-500RC is not used. 

 
The optional ALS-500RC Remote Control Head can be used with the ARI-500.  The ALS-500RC provides current  metering (ALS-
500M) or RF power output metering (ALS-600), TX and O/L (Fault) indications of the amplifier, and O/L resetting of the amplifier 
via the ALS-500RC ON/OFF switch by cycling power on the ALS-500M, or operating as a OPERATE/STANDBY switch with the 
ALS-600.  
  
To use the ALS-500RC Remote Control Head with the ARI-500:   

1)  Connect a RJ-45 patch cable to Remote port A of the ARI-500. 
2)  Connect the other end of this RJ-45 cable to port A of the ALS-500RC remote. 
3)  ALS-500RC Port B is not used in this application. 

  

Note:

   JMP 2 inside the ARI-500 must be set as described below when the ALS-500RC is used: 

 

1)

 

JMP 2 in the 1-2 position (Fig. A):  Factory default.  Must be strapped this way when the ALS-500RC is NOT used.  

2)

 

JMP 2 in the 2-3 position (Fig. B):  Strapping position when using the ALS-500RC.  The Current/RF Power Meter, Power, 
TX and O/L indicators are all functional.  The ARI-500 Auto O/L Reset (Fig. C) is automatically disabled.  The ALS-500RC 
POWER  switch  turns  the  ALS-500M  power  ON  and  OFF,  and  functions  as  the  ALS-600  OPERATE/STANDBY  switch.  
Manually reset O/L on both amplifiers by switching the ALS-500RC’s POWER Switch OFF and then ON.  When the ALS-
500RC POWER is switched ON, it takes about four seconds for the ALS-500 to turn on or the ALS-600 to reset.   

 
  
 
 
 

   
Note:

  JMP 2 

MUST

 be in the Factory Default position (FIGURE A) if the ALS-500RC Remote Control Head is 

NOT

 used. 

 

Note:

  JMP 3 should be set to OFF (Figure C) when using the ALS-500RC, as the ALS-500RC provides manual reset functionality. 

  

ARI-500 Transceiver Compatibility 

 

 

The ARI-500 is compatible with most ICOM, Kenwood and Yaesu radios for reading band data information and detecting transmitter 
keying.  Additionally, the ARI-500 low drive current keying interface is compatible with virtually any transceiver’s amplifier keying 
output.  Newer Kenwood radios have a DB-9 male connector for computer control.  Serial data is read from this port to get the band 
data.  ICOM Transceivers use a “step voltage” for band data.  A voltage of 0-8 volts is output from the band data pin of the accessory 
jack.  Yaesu, older Kenwood, and Elecraft K3 radios output band data in a 4-line BCD format (the Unified Microsystems plan).    
 
Many other transceivers use the 4-line BCD standard as well.  Check your transceiver’s instruction manual to see if this is the case.  If 
so, it will also be compatible with the ARI-500. 
  

 
 
 
 

JMP 2 

JMP 2 

FIGURE A 

(Factory Default) 

FIGURE B 

Содержание ARI-500

Страница 1: ...AMERITRON ARI 500 AUTOMATIC BAND SWITCH FOR THE ALS 500M ALS 600 AMPLIFIERS INSTRUCTION MANUAL AMERITRON 116 WILLOW ROAD STARKVILLE MS 39759 USA 662 323 8211...

Страница 2: ...e ARI 500 is designed to automatically select the correct frequency range on these amplifiers by reading the frequency information or band data from the transceiver This automatic switch is compatible...

Страница 3: ...e 1 2 position Fig A Factory default Must be strapped this way when the ALS 500RC is NOT used 2 JMP 2 in the 2 3 position Fig B Strapping position when using the ALS 500RC The Current RF Power Meter P...

Страница 4: ...he connections required between ICOM radios and the ARI 500 Connection to an ICOM IC 7000 requires an ICOM approved modification Follow the instructions in your IC 7000 user s manual page 140 to make...

Страница 5: ...e correct Band Data connections Please note that Pin 8 on the Yaesu connector TX INH must be connected to ground Pin 3 on the FT MP 2000 9000 series of radios This connection is optional on the FT 857...

Страница 6: ...RI 500 is first turned on the Auto Information AI command is sent to the radio This command causes the Kenwood radio to output the state of the radio frequency mode etc anytime the state has changes T...

Страница 7: ...ear View of Kenwood Transceiver The Kenwood TS 480 requires different connections See the Addendum in the rear of this manual Kenwood TS570 870 2000 Interface to ARI 500 Connection ARI 500 Radio Input...

Страница 8: ...uitry by cycling the ALS 500M amplifier s power OFF and back ON the ALS 500M amplifier s power switch must be in the OFF position for the Auto Load Fault reset to work or by remotely cycling the ALS 6...

Страница 9: ...ARI 500 manual radio manual and information about your station available during the call We strongly recommend calling Ameritron with any questions but questions can also be mailed directly to Ameritr...

Страница 10: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 10 Schematic...

Страница 11: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 11...

Страница 12: ...ARI 500 Automatic Band Switch for ALS 500 600 Instruction Manual 12...

Страница 13: ...Card 2 Notify Ameritron or its nearest authorized service facility as soon as possible after discovery of a possible defect of a the model number and serial number if any b the identity of the seller...

Отзывы: