Version 0A
16
Installation
Please look your amplifier and power supply over carefully. Observe the air inlet and
outlet ventilation holes. Facing the amplifier front panel, the cooling air inlets are on the
top left and lower right side, including the right hand side cabinet bottom. Warm air exits
vents at the cabinet rear.
While outlet air will not be particularly hot, it is never a good idea to have warm air blow
into heat sensitive equipment, such as transceivers or other power amplifiers. Have the
same consideration for your new amplifier and power supply. Be sure air inlet
temperature is not substantially above normal room temperature. Ideally, the air inlet
temperatures should be below 32°
C or 90° F, although temperatures up to 41°
C or
106° F are permissible. Should ambient temperatures exceed these limits, it might
become necessary to reduce duty cycle or power.
Warning:
Do not block cooling air inlets and outlets!
Never expose the amplifier to excessive heat, dirt, water, or mist.
Installation Clearances
The amplifier must have a clear area to the bottom, both sides, and top for proper
airflow and to the rear for exhaust air and interconnection wiring. It is especially
important to avoid obstructions that block the air inlet on the top left, as well as both
lower sides. One to two inches clearance is normally adequate for full ventilation. Keep
any papers or loose objects that might impede airflow away from the air inlets and
outlets.
Locate the amplifier and power supply away from sensitive equipment such as
microphones, audio processing equipment, or low level audio or radio frequency
amplifiers. Generally, the best location for the power supply is below the operating desk
and away from antenna feedlines. This will minimize unwanted mechanical, acoustical,
and electrical coupling.
The power supply produces very little heat, but the air inlet and outlet must remain open
to normal room temperature air.
Installation Warnings
Accessory Equipment and Devices
Second to operator error, the most common amplifier failure or erratic fault protection
shutdown is from antenna switches, lightning protection devices, or baluns with lightning
spark gaps in high SWR coaxial lines. Do not use 50-ohm lightning protection devices
on lines with high SWR, such as between and antenna and antenna tuner. Be sure any
lighting protection devices are in working order.
Installation, Wiring, and Connections
The ALS-600SPS switching power supply is factory wired for 100-130 Vac. The linear
ALS-600PS is prewired for 120-125 Vac nominal voltage. Both use standard NEMA-5-
Содержание ALS-606
Страница 1: ......
Страница 2: ...Version 0A 2 Notes...
Страница 12: ...Version 0A 12 Figure 1 Quick Starts Typical Wiring...
Страница 21: ...Version 0A 21 Interconnection Wiring Figure 2 Amplifier Interconnection...
Страница 32: ...Version 0A 32 Schematics Filter 1KWF6 Figure 7 1KWFL6 Filter Board...
Страница 34: ...Version 0A 34 Control Board CB2 Figure 10 Control Board CB2 Part 1 Figure 11 Control Board CB2 Part 2...
Страница 35: ...Version 0A 35 Metering Board MB2 Figure 12 Meter Board MB2...
Страница 36: ...Version 0A 36 PA Module PAM 606 Figure 13 PA Module PAM 606 Power Attenuator PD8m Figure 14 Attenuator PD8m...
Страница 38: ...Version 0A 38 ALS 600PS Power Supply Figure 16 ALS 600PS Power Supply...
Страница 39: ...Version 0A 39 Figure 17 ALS 600PS Board...
Страница 43: ...Version 0A 43 NOTES...