1. Place the outdoor unit on the support base.
2. Secure the foot holes of the outdoor unit with bolts (as shown below).
Foot holes
Foot holes
Installing the Refrigerant Piping
Flaring Process
1. Hold the pipe downward to prevent cuttings from entering the pipe.
2. Cut the refrigerant pipe with the pipe cutter and remove the burrs.
3. Remove the flare nuts at the stop valve of the outdoor unit and inside the accessory bag of the
indoor unit, put them onto the refrigerant pipe as shown below then flare the refrigerant pipe
with a flaring tool.
4. Check if the flare part is spread evenly and there are no cracks.
Bending Pipes
1. The pipes should be shaped by your hands or a refrigerant pipe bending tool for tighter bends.
Be careful not to collapse them.
2. Do not bend the pipes in an angle more than 90°.
3. When pipes are repeatedly bent or stretched, the material will be prone to damage, which may
lead to refrigerant leaks. Do not bend or stretch the pipes more than three times.