Section 2. Unit Location Considerations
2.1 Unit Dimensions and Weight
2.2 Refrigerant Piping Limits
1. The maximum TOTAL length of refriger-
ant lines from outdoor to indoor unit should
NOT exceed 150 feet (including lift).
2. The maximum vertical change should not
exceed 50 feet.
3. Service valve connection diameters are
shown in Table 5.1.
Note:
For other line lengths, Refer to Refriger-
ant Piping Application Guide, SS-APG006-EN
or Refrigerant Piping Software Program, 32-
3312-03 (or latest revision).
When mounting the outdoor unit on a roof, be
sure the roof will support the unit’s weight.
Properly selected isolation is recommended to
alleviate sound or vibration transmission to the
building structure.
Unit Dimensions and Weight
Models
H x D x W (in)
Weight* (lb)
M4AC6018A
29 x 30 x 33
161
M4AC6024A
29 x 30 x 33
162
M4AC6030A
42 x 30 x 37
184
M4AC6036A
37 x 34 x 37
212
M4AC6042A
45 x 34 x 37
272
M4AC6048A
45 x 34 x 37
272
* Weight values are estimated.