10
16 Series Mini-Split
Operating Ranges
Cooling Only Operating Range
Outdoor Temperature 0 - 115°F (-18.0 - 46.1°C)
Heat Pump Operating Range
Outdoor Temperature -4.0 - 75°F (-20.0 - 24°C)
Connection Pipe Requirements
NOTICE
The maximum distance of the connection piping in both height and total length is provided in the
table below. Do not install these units in locations that exceed these specifications.
NOTES:
1. The connection pipes should be insulated with proper water-proof insulating material
2. Wall thickness of pipe 0.02-0.04 in (0.5-1.0 mm): bearing pressure 435 PSI (3.0 MPa).
3.
Shorter connecting pipe lengths result in greater thermal efficiency, so it is preferable to reduce
connecting pipe lengths where possible.
4.
Refer to the oil trap instructions for specific requirements when there is height difference
between the indoor and outdoor unit greater than 20 feet (6m).
Heat Pump
4TXK1609
4TXK1612
4TXK1618
4TXK1624
4MXW1609
4MXW1612
4MXW1618
4MXW1624
Refrigerant Charge (oz.)
24.7
30
49.4
65.3
Standard Length ft (m)
25 (7.6)
Additional Refrigerant Charge (oz/ft)
For Piping Beyond Standard Length
0.2
0.5
Outer Diameter
Liquid Pipe in (mm)
Φ
1/4" (6.35)
Gas Pipe in (mm)
Φ
3/8" (9.52)
Φ
1/2" (12.7)
5/8" (15.875)
Max Distance
Height ft (m)
65 (20)
Length ft (m)
100 (30)
130 (40)
Minimum Piping Length ft (m)
10 (3)
Compressor Oil Used
DAPHNE FVC50K (PVE Oil)
RB68EP (POE Oil)
Cooling Only
4TYK1609
4TYK1612
4TYK1618
4TYK1624
4MYW1609
4MYW1612
4MYW1618
4MYW1624
Refrigerant Charge (oz.)
24.7
30
35.3
56.4
Standard Length ft (m)
25 (7.6)
Additional Refrigerant Charge (oz/ft)
For Piping Beyond Standard Length
0.2
Outer Diameter
Liquid Pipe in (mm)
Φ
1/4" (6.35)
Gas Pipe in (mm)
Φ
3/8" (9.52)
Φ
1/2" (12.7)
5/8" (15.875)
Max Distance
Height ft (m)
65 (20)
Length ft (m)
100 (30)
130 (40)
Minimum Piping Length ft (m)
10 (3)
Compressor Oil Used
DAPHNE FVC50K (PVE Oil)
RB68EP (POE Oil)