AmeriFlow Water Systems Inc. ET6500 Скачать руководство пользователя страница 13

 07\15 RO Manual     

12

Water does not 

taste or smell 

right.

Bad membrane.

Replace membrane when below 75% rejection and 

sanitize.

Filters have expired.

Replace filters. Should be replaced every 6 to 12 

months.

Little water use.

Drain or use entire tank. Should be done every 2 weeks 

if low water use.

System needs sani-

tizing.

Sanitize (see Step 11: Recommended Sanitizing In-

structions) and replace filters.

Little water from 

faucet.

Over pressurized 

tank.

When empty, tank pressure should be between 5-12 

PSI.

Incoming water pres-

sure is below 40 PSI.

Increase pressure to 40 PSI with a pump.

New system or filters 

just changed.

System takes 4 to 12 hours to completely fill.

Bad check valve.

Replace check valve.

Tank valve not open.

Open valve.

Bad storage tank.

Replace storage tank. If not bad check that tank air 

pressure is between 5-12 PSI when empty.

Filters clogged.

Replace filters.

Kinked tube.

Un-kink tube. If damaged, replace tube.

System is con-

tinually running.

Shut off valve not 

working.

Replace shut off valve.

Low city supply water 

pressure.

Increase water pressure to 40 PSI with a pump.

Bad check valve.

Replace check valves.

Ice being made in 

refrigerator.

Nothing you can do, ice is made on demand.

System is new.

Allow 2 weeks for air to bleed.

Ice maker not 

working.

Ball valve to ice line 

is off.

Turn on ball valve.

Ice maker in refrig-

erator is off.

Turn to on position.

Ice maker line frozen. Thaw with hair dryer. Make sure you have a full tank of 

water before turning ice maker on.

Tube to refrigerator is 

kinked.

Find kink and repair.

No water out 

of refrigerator 

door.

1-quart reservoir 

not full.

Hold down dispenser handle for approximately 3 min-

utes until water comes out. Make sure R/O tank is full.

Makes water 

slowly.

Normal R/O process. Your R/O system makes water a drop at a time. 3-gallon 

storage tank should be full in 4-12 hours.

Low city water pres-

sure.

Increase to 40 PSI. with a booster pump.

Kinked tubing.

Find kink and repair.

Filters plugged.

Replace filters.

Bad membrane.

Replace membrane.

Содержание ET6500

Страница 1: ...07 15 RO Manual A Owners Manual FOR REVERSE OSMOSIS SYSTEMS MODEL ET6500 P N 10 02 1330 Includes Installation and Service Procedures Specifications and Operation Guidelines ...

Страница 2: ...Benefits 2 Specification Limitations 2 Warnings 3 Photo of ROs and Contents List 4 Installation Procedures 4 System Position 4 Faucet Installation 4 Figure 1 Diagram 5 Easy Tap Adapter Installation 5 Drain Saddle Clamp Installation 5 Figure 2 Diagram 6 Storage Tank Preparation 6 Tubing Connections 6 System Start Up Procedures 7 Refrigerator Icemaker Hookup 8 Recommended Filter Service Life 7 Filte...

Страница 3: ... coolers 16 Bottled Water CONTENTS OF PACKAGE 1 Filter Pac RO module 2 Storage Tank 3 Owner s Manual 4 Warranty Registration Card 5 Standard air gap faucet or optional col ored faucet 6 Parts Bag Easy Tap Adapter w washer plastic Drain Clamp black plastic Coupler plastic for use w air gap faucet Faucet Adapter plastic 7 16 fip 3 8 push Tank Ball Valve Mounting Screws 7 Water quality monitor TOOLS ...

Страница 4: ... line 9 Water containing iron in excess of 1ppm will require some pretreatment Consult your local water authority 10 This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction pe...

Страница 5: ...the Filter Pac RO module and that the mounting screws will not pierce through the wall Hang Filter Pac RO module to assure sufficient space is allowed Remove Filter Pac RO module from the wall for now and continue with install STEP 2 FAUCET INSTALLATION 1 Check for an extra hole in the sink You must drill a 1 hole for the faucet if the sink does not have one Determine Location of Faucet Hole Check...

Страница 6: ...cation of Drain Clamp SINK WITH DISPOSAL Select location to place drain saddle clamp Best choice is the vertical pipe as near the sink as possible making certain that the drain clamp is above the horizontal garbage disposal waste pipe When connecting the black drain tube to drain saddle clamp keep the tube run as straight FIGURE 1 countertop faucet stem B A F slot washer white spacer washer lock w...

Страница 7: ...nd tank air pressure 4 Tank pressure can be increased to improve water flow to the faucet or refrigerator Air pressure can only be tested when tank is completely empty of water Air pressure of 5 PSI minimum 12 PSI maximum is recommended The higher the air pressure the smaller the volume of water the tank will hold Pressure of 10 12 PSI may be necessary to feed a line to the refrigerator Over press...

Страница 8: ...refill and drain again in 4 to 6 hours The RO system is shipped with a food grade preservative and must be flushed out prior to use DO NOT DRINK THE RO WATER UNTIL TANK HAS BEEN DRAINED TWICE 3 Shut RO faucet off and let system fill again RO water is now ready for use IMPORTANT Check carefully for small leaks every few hours for the first few days to assure there are no leaks It is wise on any RO ...

Страница 9: ...ng on influent water quality and hardness See Performance Indicator information listed below Carbon Post filter Carbon MAP Filter These filters need to be changed at least every 12 months to insure quality water Do not wait until taste is a problem Performance indicator The RO system contains a replaceable treatment component criti cal for effective reduction of TDS Total Dissolved Solids The prod...

Страница 10: ...in off po sition Remove old pre filters and membrane from housings Remove the post filter On the ET5000 a 3 8 union and on the ET6000 a 3 8 reducer union not included will be necessary to reconnect the tubing together without the post filter installed during sanitizing procedures 4 Carefully put 2 capfuls of household bleach into the empty filter bowl canisters Re install filter bowls without filt...

Страница 11: ...419 1404 1 JG 90 Ball Valve 2 804 11 04 Hex Nipple 1 419 1406 3 8 JG 90 Ball Valve Storage Tank 2 3 805 40 02 Fitting mpt JG Elbow ET6000 1 123 541 Water Conservation Shut Off Valve 1 128 00 RO Membrane Housing 1 128 R O ring Membrane Housing 2 805 40 04 Fitting 1 8 mpt JG Elbow 1 121 1604 1 Check Valve Fitting 1 8 mpt JG Elbow 1 129 260 Flow Restrictor 260 ml 1 110 03181 3 2 Gallon Storage Tank 1...

Страница 12: ...glass of water If just air will float to surface and dissipate System is still new This is normal and should clear up in two weeks Noisy drain or faucet Air gap faucet A little noise is common with air gap faucets Check manual to be sure installed in proper location Allow two weeks for air to work out of system Drain tube Check that drain tube from faucet is continuously down hill to drain Loops o...

Страница 13: ... If damaged replace tube System is con tinually running Shut off valve not working Replace shut off valve Low city supply water pressure Increase water pressure to 40 PSI with a pump Bad check valve Replace check valves Ice being made in refrigerator Nothing you can do ice is made on demand System is new Allow 2 weeks for air to bleed Ice maker not working Ball valve to ice line is off Turn on bal...

Страница 14: ...e product water shall be tested regularly to verify that the system is perform ing properly Testing can be accomplished by contacting the service company that installed your RO system or an authorized dealer If a service company is not available in your area a water sample may be sent to AmeriFlow for a free TDS test of your RO water Additionally a water quality monitor is available for purchase f...

Страница 15: ...o the customer freight prepaid This warranty does not cover any defects or damage resulting from water pressure exceeding 85psi misuse misapplication neglect alterations accident improper maintenance or instal lation contrary to manufacturer s printed instructions and specifications casualties fire flood Reverse Osmosis drain line plugging sediment scale fouling water temperatures over 110 F freez...

Страница 16: ...h other nonaffiliated companies We reserve the right to communicate with you via direct mail email or telephone pertaining to our products and services We limit access to your personal infor mation to those employees whose job requires them to communicate with you regarding our products and services By registering your product the original purchaser will be entitled to the full benefits of AmeriFl...

Страница 17: ...07 15 RO Manual 16 ...

Отзывы: