Operational Conditions

Anode Rod/Water Odor

Each water heater contains at least one anode rod, which 
will slowly deplete while protecting the glass-lined tank 
from corrosion and prolonging the life of the water heater. 
Once the anode is depleted, the tank will start to corrode, 
eventually developing a leak. Certain water conditions will 
cause a reaction between this rod and the water.  The most 
common complaint associated with the anode rod is a “rotten 
egg smell” produced from the presence of hydrogen sulfide 
gas dissolved in the water. 
IMPORTANT: Do not remove this rod permanently as it will 
void any warranties.

 

The parts list includes a special anode 

that can be ordered if water odor or discoloration occurs.
NOTE: This rod may reduce but not eliminate water odor 
problems. The water supply system may require special 
filtration equipment from a water conditioning company to 
successfully eliminate all water odor problems. 
Artificially softened water is exceedingly corrosive because 
the process substitutes sodium ions for magnesium and 
calcium ions. The use of a water softener may decrease the 
life of the water heater tank. 
The anode rod should be inspected after a maximum of three 
years and annually thereafter until the condition of the anode 
rod dictates its replacement.  NOTE: Arti

fi

 cially softened water 

requires the anode rod to be inspected annually. 
The following are typical (but not all) signs of a depleted 
anode rod:
• 

The majority of the rods diameter is less than 3/8”.

• 

Significant sections of the support wire (approx. 1/3 or 
more of the anode rod’s length) are visible.

If the anode rod shows signs of either or both, it should be 
replaced. 
NOTE: Whether reinstalling  or 
replacing the anode rod, check for 
any leaks and immediately correct if 
found.  In replacing the anode:
1.  Turn off power to the water heater.
2.  Shut off the water supply and 

open a nearby hot water faucet 
to depressurize the water tank.

3.  Drain approximately 5 gallons 

of water from tank (Refer to the 
“Draining and Flushing” section 
for proper procedures). Close 
drain valve.

4.  Remove old anode rod.
5. Use 

Teflon

®

 tape or approved 

pipe sealant on threads and 
install new anode rod.

6.  Turn on water supply and open 

nearby hot water faucet to purge air from water system. 
Check for any leaks and immediately correct any if found.

7.  Restart the water heater as directed under the 

“Operating Your Water Heater” section.  See the “Repair 
Parts Illustration” section for anode rod location.

®

TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

Water Heater Sounds

During the normal operation of the water heater, sounds or 
noises may be heard. These noises are common and may 
result from the following:
1.  Normal expansion and contraction of metal parts    

during periods of heat-up and cool-down.

2.  Sediment buildup in the tank bottom will create    

varying amounts of noise and may cause  premature 
tank failure. Drain and flush the tank as directed under 
the “Draining and Flushing” section.

Stacking

Stacking occurs when a series of short draws of hot water 
(3 gallons or less) are taken from the water heater tank. 
This causes increased cycling of the heater elements and 
can result in increased water temperatures at the hot water 
outlet. An anti-scald device is recommended in the hot 
water supply line to reduce the risk of scald injury.

Figure 11:
Anode Rod Depletion

Содержание Residentian Electric Water Heater

Страница 1: ...ber 4 Date of installation 5 Place of Purchase Water Heater Safety 2 Installing Your Water Heater 3 8 Unpacking Instructions 3 Location Requirements 4 Electrical Requirements 5 Water System Piping 6 I...

Страница 2: ...heater that has not been used for a long period of time 2 weeks or more Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that the hot water fau...

Страница 3: ...manual If you lack the necessary skills required to properly install this water heater or you have difficulty following the directions you should not proceed but have a qualified person perform the i...

Страница 4: ...area or call 1 800 999 9515 and request instructions 2 1 2 Maximum Pipe to adequate drain At least 2 greater than the diameter of the water heater IMPORTANT The water heater should be located in an a...

Страница 5: ...e electrical supply to the water heater A standard 1 2 inch opening has been made in the junction box for conduit connections 5 Connect ground wire to green ground screw in the junction box of the wat...

Страница 6: ...lable Contact a licensed plumber or the local plumbing authority for more information 4 If installing the water heater in a closed water system install an expansion tank in the cold water line as spec...

Страница 7: ...the installation of a thermal expansion tank IMPORTANT Do not plug or remove the temperature and pressure relief valve Closed System Thermal Expansion For protection against excessive pressures and t...

Страница 8: ...nded that the discharge pipe be terminated at an adequate drain inside the building Shall be of material listed for hot water distribution Shall be installed to allow complete drainage of both the val...

Страница 9: ...the high limit control switch continues to shut off the water heater contact a qualified person for service Water Temperature Regulation Water temperature over 125 F can cause severe burns instantly o...

Страница 10: ...d person 1 Disconnect the electric power 2 Remove the access cover s and fold up the insulation from the thermostat s Do not remove the plastic cover 3 Using a screwdriver to adjust the thermostat poi...

Страница 11: ...ngth are visible If the anode rod shows signs of either or both it should be replaced NOTE Whether reinstalling or replacing the anode rod check for any leaks and immediately correct if found In repla...

Страница 12: ...r s Fold up the insulation from the heater element s Remove the plastic thermostat cover from the thermostat s making sure to disengage the attachment point from the thermostat 4 Disconnect the electr...

Страница 13: ...for source of trouble and correct 3 Replace thermostat or element INSUFFICIENT HOT WATER 1 Non Functioning thermostats 2 Non Functioning lower element 3 Improper calibration 4 Thermostats set too low...

Страница 14: ...14 REPAIR PART ILLUSTRATION 1 1 2 3 5 6 7 2 6 4 5 8 7 10 9 8 11 12 14 13 ALTERNATE T P LOCATION 7 17 18 8 13 6 16 2 3 5 6 5 2 4 15 14 9 11 TABLE TOP MODEL...

Страница 15: ...TUBE COMBINATION 20 FLANGE REPAIR PARTS Repair parts may be ordered through your plumber local distributor home improvement center or by calling 1 800 999 9515 When ordering repair parts always give...

Страница 16: ...AL SERVICE GROUND GROUND SCREW 1 2 1 2 FUSED DISCONNECT OR CIRCUIT BREAKER LOWER ELEMENT BLACK BLACK BLUE BLUE UPPER ELEMENT YELLOW YELLOW L1 L2 FUSED DISCONNECT OR CIRCUIT BREAKER RED UPPER THERMOSTA...

Отзывы: