8”
GAS VALVE
DRAIN VALVE
HOT
CONNECTION
COLD
CONNECTION
ANODE ROD
ON/OFF SWITCH
FRONT VIEW
TOP VIEW
DRAFT HOOD
T&P VALVE
1/2”
E
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA 4.1 standards.
1992. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a corrosion-resistant lining; polymer linings
are not acceptable. Each tank shall be furnished with an internal powered anode for cathodic protection. The unit must be equipped with a combination gas control
thermostat and non-reset type ECO. A corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted
NRGSS01010 May 2011R
All dimension in inches.
Recovery capacity based on actual performance tests.
Water Connections – 3/4” on all models.
Not available in LP gas (Propane).
Flammable Vapor Ignition Resistant Water Heaters
This FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - CSA 4.1 Standards) that deal with the
MODEL
NUMBER
GALLON
CAPACITY
ENERGY
FACTOR
BTU INPUT
PER HOUR
RECOVERY
AT 90°
RISE
FIRST
HOUR
RATING
FOAM
THICKNESS
(INCHES)
DIMENSIONS IN INCHES
DRAFT
HOOD
OUTLET
SHIPPING
WEIGHT
(LBS)
A
B
C
D
E
F
PCG6240T403NOV
40
.70
40,000
43
70 GPH
2
20
61-3/4
58
51-1/2
23-1/4
25
3 or 4
157
PCG6250T403NOV
50
.70
40,000
43
81 GPH
2
22
60-5/8
57-1/8
50-1/2
25-1/4
27
3 or 4
171
Maximum Hydrostatic Working Pressure: 150 PSI
Heaters shall meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of
SERIES
102
100
Certified for installations up to 10,100 ft. elevations.