8”

GAS VALVE

DRAIN VALVE

HOT 

CONNECTION

COLD

CONNECTION

ANODE ROD

ON/OFF SWITCH

FRONT VIEW

TOP VIEW

DRAFT HOOD

T&P VALVE

1/2”

E

Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank 
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated 
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA 4.1 standards.  

1992.  The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F,  forming a corrosion-resistant lining; polymer linings 
are not acceptable.  Each tank shall be furnished with an internal powered anode for cathodic protection.  The unit must be equipped with a combination gas control 
thermostat and non-reset type ECO.  A corrosion-resistant drain valve shall be provided on the front of each unit.  The tank shall be totally encased in a steel jacket, painted 

NRGSS01010       May 2011R

All dimension in inches.
Recovery capacity based on actual performance tests.
Water Connections – 3/4” on all models.
Not available in LP gas (Propane).

Flammable Vapor Ignition Resistant Water Heaters

This FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - CSA 4.1 Standards) that deal with the  

MODEL

NUMBER

GALLON 

CAPACITY

ENERGY

FACTOR

BTU INPUT 

PER HOUR

RECOVERY 

AT 90° 

RISE

FIRST 

HOUR 

RATING

FOAM 

THICKNESS 

(INCHES)

DIMENSIONS IN INCHES

DRAFT 

HOOD 

OUTLET

SHIPPING 

WEIGHT

(LBS)

A

B

C

D

E

F

PCG6240T403NOV

40

.70

40,000

43

70 GPH

2

20

61-3/4

58

51-1/2

23-1/4

25

3 or 4

157

PCG6250T403NOV

50

.70

40,000

43

81 GPH

2

22

60-5/8

57-1/8

50-1/2

25-1/4

27

3 or 4

171

Maximum Hydrostatic Working Pressure: 150 PSI

Heaters shall meet the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of

SERIES

102

100

Certified for installations up to 10,100 ft. elevations.

236830_NRGSS01010.indd   2

236830_NRGSS01010.indd   2

5/27/11   9:03 AM

5/27/11   9:03 AM