Fig. 2
3-3/4"
(96mm)
2-3/4"
(71mm)
3"
(76mm)
6
4
5
2
2
3
1
1
MOUNTING
BRACKET
SUPPLIES
WASTE
ENCLOSURE
MOUNTING
HOLES
3
1524mm
(60)
20"
(500mm)
MOUNTING
BRACKET
NOTE: If using Mixing Valve (optional) See Sheet
#M968808 for installation instructions.
1.
For installation on Infection Control Sink mount
ENCLOSURE
(1)
on MOUNTING BRACKET
(2)
with
SCREWS
(3)
.
2.
For all other sinks or countertops determine location of
ENCLOSURE
(1)
. It must be located within the 14"
(356mm) by 21" (533mm) shaded area shown in
Figure 2
in order for electrical connections from the spout
assembly to be completed.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance
between wall supply and ENCLOSURE (1) must be
taken into consideration.
3.
Remove 4 screws from COVER
(6)
and pull off COVER
(6)
. Hold the ENCLOSURE
(1)
in desired location and
mark the four mounting hole locations as shown.
Fig. 2.
4.
The ENCLOSURE
(1)
works best if secured to a wall
stud or cross brace within the wall, using the SCREWS
(4)
supplied. If the ENCLOSURE
(1)
is to be installed on a tile
or plaster wall the ANCHORS
(5)
and SCREWS
(4)
should be used.
Fig. 2.
5.
For installations on drywall or tiled walls;
use
ANCHORS
(5)
and SCREWS
(4)
for securing
ENCLOSURE
(1)
to finished wall. Drill four 1/4" dia. holes
a minimum of 1-3/4" deep. Insert the four ANCHORS
(5)
flush with face of the finished wall.
Align the ENCLOSURE
(1)
and Install the MOUNTING
SCREWS
(4)
. Tighten to secure ENCLOSURE
(1)
to
mounting surface.
NOTE. The illustration shows the Infection Control
FAUCET mounted on the American Standard Infection
Control Sink. Faucet can be installed on almost any sink
or countertop. For Faucet installation on the American
Standard Infection Control Sink, see instruction sheet
No. 7301793-100 (Infection Control Sink System) supplied
with Sink for more detailed information.
NOTE: For AC installation see “AC VERSION; Fig. 2.”
Make power supply connection before mounting
ENCLOSURE (1) to wall.
MOUNT ENCLOSURE; Fig. 2
2
1.
Connect SUPPLY NUT
(1)
from spout assembly to
nipple on top of ENCLOSURE
(2)
. Tighten with adjustable
wrench to make a water tight connection.
Fig. 3.
NOTE; If using the optional Mixing Valve See Sheet
#M968808 for installation instructions.
CONNECT SPOUT HOSE TO
ENCLOSURE; Fig. 3
CONNECT WATER SUPPLY TO
ENCLOSURE AND WALL SUPPLY;
Fig. 4
3
Fig. 3
4
1
2
1
3
3
Fig. 4
2
1.
Insert FIBER WASHER
(4)
into SUPPLY NUT
(1)
on
ENCLOSURE
(2)
.
2.
Connect SUPPLY NUT
(1)
on ENCLOSURE
(2)
to
FLEXIBLE SUPPLY HOSE
(3)
. Tighten to make a water tight
connection. Use two wrenches to tighten if necessary.
Fig. 4.
3.
Connect FLEXIBLE SUPPLY
(3)
directly to wall supply.
Connection on FLEXIBLE SUPPLY
(3)
is 3/8" compression.
Use adjustable wrench to tighten connection. Do not over
tighten.
Fig. 4a.
Note:
FLEXIBLE SUPPLY
(3)
measures 20" from the bottom
of the ENCLOSURE
(1)
base. If additional supply length is
required, installer must purchase parts separately.
Important:
If FLEXIBLE SUPPLY
(3)
is too long, loop to avoid kinking.
COLD WATER OR
TEMPERED
WALL SUPPLY
OTHER SINK
INSTALLATION
Fig. 4a
4
M 9 6 5 119 R E V. 1. 3
14"
(356mm)
21"
(533mm)