5
TYPICAL
INSTALLATION
NOTE:
When connecting more than one appliance into
a common chimney, the water heater’s vent
connector must enter the chimney above all other
vent connectors.
Do not vent a natural draft appliance (such as this
heater) and a forced draft or power vent appliance
into the same chimney.
VentTermination Horizontal 12” min. above grade/
snow level.
State of California Note:
The water heater must be braced,
anchored, or strapped to avoid moving
during an earthquake.
Contact local utilities for code
requirement in your area or call
1-888-883-0788 and request instructions
PIPING MUST MEET ALL LOCAL CODE REQUIREMENTS.
NOTE: wate heater must be installed level
FIGURE 4
1.
2.
3.
INSTALL LEGS INTO
SLOTS ON THE
HEATER TOP COVER
4" FLUE HEATER
3" FLUE HEATER
DO NOT EXTEND VENT
CONNECTOR BEYOND
INNER EDGE OF CHIMMEY
SEAL TIGHTLY
VENT CONNECTOR
HOT WATER OUTLET
DRAFT HOOD
DRAFT HOOD RELIEF OPENNING
MANUAL GAS SHUT OFFVALVE
GROUN JOINT UNION
DRIP LEG (SEDIMENT TRAP
MINIMUM LENGTH 3"
DRAIN
MUST LIMIT WATER
ACCUMULATION TO
A MAXIMUM HEIGHT
OF 1
3/4"
DRAIN LINE
SHOULD BEAT LEAST 3/4" IN AND
PITCHED FOR PROPER DRAINAGE
TO AN OPEN DRAIN
DISCHARGE LINE (EXTEND TO AN OPEN DRAIN)
IT MUST BE AT LEAST 3/4" IN AND PITCHED FOR PROPER
DRAINAGE TO AN OPEN DRAIN. DO NOT THREAD, CAP OR
PLUG THE END
GAS CONTROL VALVE (THERMOSTAT)
DATA PLATE AND LIGHTING
INSTRUCTION LOCATION
TEMPERATURE AND PRESSURE RELIEF VALVE
••SOME MODELS MAY HAVE THE TEMPERATURE & PRESSURE
RELIEF VALVE TAPPING ON TOP OF HEATER
SHEET METAL
SCREWS
CLOSED WATER
SYSTEM
EXPANSION
TANK
PRESSURE REDUCING
VALVE WITH BYPASS
COLD WATER
INLET
COLD
WATER
INTEL
VALVE
CAP
MINIMUN UPWARD PITCH 1/4"
PER FOOT
COLD
TEMPERED
WATER
(TO FIXTURES)
TEMPERING
VALVE
(SET TO 120°F)
FOLLOW THE TEMPERING VALVE
MANUFACTURER´S INSTRUCTION